| Kikusui | PAD70-8L | Power Supply 0-70v 0-8a | ||||
| Kikusui | PAD8-50L | Power Supply 0 - 8V 0 - 50A | http://www.kandelelex.com/jpegs/kikpad8-50l.jpg | in stock | ||
| Kikusui | PAK20-18A | DC Power Supply 0-20V 0-18A digital switching | Kikusui PAK20-18A. DC POWER SUPPLY, 0-20V, 0-18A The PAK-A Series is a variable output, switching power supply that feature excellent electrical characteristics as well as unmatched reliability. This Series offers a wide range of variation consisting of 8 models with 3 types of voltage. This Series is designed particularly with the concepts of compact size and light weight plus high reliability, and is portable with an improved space factor making them suitable for system mounting. Naturally, these power supplies have a high level of general-purpose applicability on abundant applications, such as computer control, or a system power supply. Especially in case of connecting with the optional power supply controllers, feature of this Series will be expanded as system of programmable power supply.
Features •Compact and Lightweight •External analog control functions •GPIB control (optional function) •Analog read-back function •Parallel and series operation •Low Acoustic Noise •Front Air Intake |
in stock | ||
| Kikusui | PAK35-10A | DC Power Supply 0 - 35V 0 - 10A Digital Switching | The PAK-A Series is a variable output, switching power supply that feature excellent electrical characteristics as well as unmatched reliability. This Series offers a wide range of variation consisting of 8 models with 3 types of voltage. This Series is designed particularly with the concepts of compact size and light weight plus high reliability, and is portable with an improved space factor making them suitable for system mounting. Naturally, these power supplies have a high level of general-purpose applicability on abundant applications, such as computer control, or a system power supply. Especially in case of connecting with the optional power supply controllers, feature of this Series will be expanded as system of programmable power supply.
Features Compact and Lightweight External analog control functions GPIB control (optional function) Analog read-back function Parallel and series operation Low Acoustic Noise Front Air Intake |
in stock | ||
| Kikusui | PAK35-20A | DC Power Supply 0-35V 0-20A Switching | The PAK-A Series is a variable output, switching power supply that feature excellent electrical characteristics as well as unmatched reliability. This Series offers a wide range of variation consisting of 8 models with 3 types of voltage. This Series is designed particularly with the concepts of compact size and light weight plus high reliability, and is portable with an improved space factor making them suitable for system mounting. Naturally, these power supplies have a high level of general-purpose applicability on abundant applications, such as computer control, or a system power supply. Especially in case of connecting with the optional power supply controllers, feature of this Series will be expanded as system of programmable power supply.
Features Compact and Lightweight External analog control functions GPIB control (optional function) Analog read-back function Parallel and series operation Low Acoustic Noise Front Air Intake Voltage: 0-35V Current: 0-20A Ripple: 10mV rms Regulation: line .05%+5mV; load .1%+5mv Input: 85-132VAC; 47-63Hz |
|||
| Kikusui | PCR1000L | AC Power Source 1000 VA | Expanded Functions:
Power line irregularity simulation; Sequencial program of voltage, frequency, waveform, etc.; Harmonics current analysis; Peak clip waveform output; Measurement of power factor, VA and peak hold current; Regulation adjustment; Output impedance setting. Output: 1000VA with voltage ranges from 1 to 150VAC(5 amps) or 2 to 300VAC(2.5 amps) and 1.4 to 212VDC(2.5 amps) or 2.8 to 424VDC(1.25 amps). Frequecy: 1 to 999.9Hz with 1 x 10(-4) accuracy and >.5% distortion. Environment testing(power outages, voltage drops, surges and peak clip). Power supply harmonic current measurement and analysis. GP-IB option available. |
|||
| Kikusui | PCR2000 | AC Power Source 2kVA 5 - 500Hz 1 - 280 VAC | Simulate power interuptions, frequency shifts, voltage spikes,
brownouts and surges. Features: Digitally synthesized output sinewave; Fully isolated output; Programmable memory for voltage and frequency(99 setpoints); LED displays for voltage, current, and frequency. |
in stock | ||
| Kikusui | PCR2000L | AC Power Source / Analyzer 2000 VA | ||||
| Kikusui | PCR500 | AC Power Source 500 VA 5 - 500Hz 1 - 280 VAC | Simulate power interuptions, frequency shifts, voltage spikes, brownouts and surges.
Features: Digitally synthesized output sinewave; Fully isolated output; Programmable memory for voltage and frequency(99 setpoints); LED displays for voltage, current, and frequency. |
http://www.kandelelex.com/jpegs/kikpcr500.jpg | in stock | |
| Kikusui | PCR500L | Programmable AC Power Source | Expanded Functions:
Power line irregularity simulation; Sequencial program of voltage, frequency, waveform, etc.; Harmonics current analysis; Peak clip waveform output; Measurement of power factor, VA and peak hold current; Regulation adjustment; Output impedance setting. Output: 500VA with voltage ranges from 1 to 150VAC(5 amps) or 2 to 300VAC(2.5 amps) and 1.4 to 212VDC(2.5 amps) or 2.8 to 424VDC(1.25 amps). Frequency: 1 to 999.9Hz with 1 x 10(-4) accuracy and >.5% distortion. Environment testing(power outages, voltage drops, surges and peak clip). Power supply harmonic current measurement and analysis. GP-IB option available. |
http://www.kandelelex.com/jpegs/kikpcr500l.jpg | in stock | |
| Kikusui | PLZ1002W | Electronic Load 1000 Watt 3 - 110V 0-200A | 1000 watts max. Input Voltage: 3 to 110V. Input Current: 0 to 200A. Digital readout of voltage and current. Automatic protection. | in stock | ||
| Kikusui | PLZ1002W | Electronic Load 1000 Watt 3 - 110V 0-200A | 1000 watts max. Input Voltage: 3 to 110V. Input Current: 0 to 200A. Digital readout of voltage and current. Automatic protection. | http://www.kandelelex.com/jpegs/kikplz1002w.jpg | in stock | |
| Kikusui | PLZ1003W | Electronic Load 1000 Watt 1.5 - 120V 200A | 1000 watts max. Input Voltage: 1.5 to 120V. Input Current: 0 to 200A. Digital readout of voltage and current. Automatic protection.
Features: Constant power mode useful for battery discharge tests Setting of various conditions Variable rise/fall time function Sequence function that allows complicated current simulations Setup function and backup memories Remote sensing that compensates precisely for set values Trigger signal output useful for waveform monitoring Three-memory function and switching function Soft-start function that suppresses output voltage distortion Short-circuit function that allows instantaneous setting of the maximum current Parallel operations that offer increased current and power capacities Option IB-11 available adds IEEE-488 interface. |
in stock | ||
| Kikusui | PLZ1003W | Electronic Load 1000 Watt 1.5 - 120V 200A | 1000 watts max. Input Voltage: 1.5 to 120V. Input Current: 0 to 200A. Digital readout of voltage and current. Automatic protection.
Features: Constant power mode useful for battery discharge tests Setting of various conditions Variable rise/fall time function Sequence function that allows complicated current simulations Setup function and backup memories Remote sensing that compensates precisely for set values Trigger signal output useful for waveform monitoring Three-memory function and switching function Soft-start function that suppresses output voltage distortion Short-circuit function that allows instantaneous setting of the maximum current Parallel operations that offer increased current and power capacities Option IB-11 available adds IEEE-488 interface. |
http://www.kandelelex.com/jpegs/kikplz1003w.jpg | in stock | |
| Kikusui | PLZ1003W | Electronic Load 1000 Watt 1.5 - 120V 200A | 1000 watts max. Input Voltage: 1.5 to 120V. Input Current: 0 to 200A. Digital readout of voltage and current. Automatic protection.
Features: Constant power mode useful for battery discharge tests Setting of various conditions Variable rise/fall time function Sequence function that allows complicated current simulations Setup function and backup memories Remote sensing that compensates precisely for set values Trigger signal output useful for waveform monitoring Three-memory function and switching function Soft-start function that suppresses output voltage distortion Short-circuit function that allows instantaneous setting of the maximum current Parallel operations that offer increased current and power capacities Option IB-11 available adds IEEE-488 interface. |
http://www.kandelelex.com/jpegs/kikplz-1003w.jpg | in stock | |
| Kikusui | PLZ1003W IB11 | Programmable Electronic Load 1000 W 1.5 - 120V 20 | 1000 watts max. Input Voltage: 1.5 to 120V. Input Current: 0 to 200A. Digital readout of voltage and current. Automatic protection.
Features: Constant power mode useful for battery discharge tests Setting of various conditions Variable rise/fall time function Sequence function that allows complicated current simulations Setup function and backup memories Remote sensing that compensates precisely for set values Trigger signal output useful for waveform monitoring Three-memory function and switching function Soft-start function that suppresses output voltage distortion Short-circuit function that allows instantaneous setting of the maximum current Parallel operations that offer increased current and power capacities |
in stock | ||
| Kikusui | PLZ1003W RS11 | Programmable Electronic Load 1.5 - 120V 200A 1000 | 1000 watts max. Input Voltage: 1.5 to 120V. Input Current: 0 to 200A. Digital readout of voltage and current. Automatic protection.
Features: Constant power mode useful for battery discharge tests Setting of various conditions Variable rise/fall time function Sequence function that allows complicated current simulations Setup function and backup memories Remote sensing that compensates precisely for set values Trigger signal output useful for waveform monitoring Three-memory function and switching function Soft-start function that suppresses output voltage distortion Short-circuit function that allows instantaneous setting of the maximum current Parallel operations that offer increased current and power capacities Option RS-11 adds RS232 programming |
in stock | ||
| Kikusui | PLZ150W | Electronic Load | Provides 4 operating modes - constant current, resistance, voltage and power. Power: 150 watts; Voltage: 4-60V; Current: 0-30A. | |||
| Kikusui | PLZ-150W | Electronic Load | Provides 4 operating modes - constant current, resistance, voltage and power. Power: 150 watts; Voltage: 4-60V; Current: 0-30A. | |||
| Kikusui | PLZ152W | Electronic Load 150 Watts max / 4 to 110 Volts / 0 | 150 watts max., 4 to 110 volts, 0 to 30 amps. | in stock | ||
| Kikusui | PLZ152W | Electronic Load 150 Watts max / 4 to 110 Volts / 0 | 150 watts max., 4 to 110 volts, 0 to 30 amps. | http://www.kandelelex.com/jpegs/kikplz152w.jpg | in stock | |
| Kikusui | PLZ-152W | Electronic Load | 150 watts max., 4 to 110 volts, 0 to 30 amps. | |||
| Kikusui | PLZ152WA | Electronic Load 150 Watts 0 - 110V 0 - 30A | The kikusui PLZ152WA is a 150 watt electronic load. Input load range: 0 to 110 volts DC (0.5V to 110V in Constant Resistance Mode), 0 to 30 amps.
Features: 2 current settings; easy static/dynamic operation using the built-in oscillator; 31/2 -digit autoranging volt and ammeter; Master slave operation; Over power, over current and auto-reverse protection. |
in stock | ||
| Kikusui | PLZ152WA | Electronic Load 150 Watts 0 - 110V 0 - 30A | The kikusui PLZ152WA is a 150 watt electronic load. Input load range: 0 to 110 volts DC (0.5V to 110V in Constant Resistance Mode), 0 to 30 amps.
Features: 2 current settings; easy static/dynamic operation using the built-in oscillator; 31/2 -digit autoranging volt and ammeter; Master slave operation; Over power, over current and auto-reverse protection. |
http://www.kandelelex.com/jpegs/kikplz152wa.jpg | in stock | |
| Kikusui | PLZ153W | Electronic Load 150 Watt 1.5 - 120V 0 - 30A | The PLZ153W is a programmable, microprocessor-based, 150w Electronic Load. It is rated for up to 120V and 30A. It features four operating modes: constant current, constant voltage, constant resistance, and constant power. The PLZ153W is simplicity itself to use. The jog/shuttle knob ramps output parameters up or down while readback is displayed on the backlit LCD display. Output connections are via knurled screws on the front panel or through-bolt on the rear panel. The PLZ153W is ideal for testing of dc power supplies and batteries. An IEEE-488 interface is available optionally for remote control applications. | http://www.kandelelex.com/jpegs/kikplz153w.jpg | in stock | |
| Kikusui | PLZ-153W | Electronic Load 150 Watt 1.5-120v 0-30a | http://www.kandelelex.com/jpegs/kikplz-153w.jpg | |||
| Kikusui | PLZ300W | Electronic Load 4 - 60V 60A 300 Watt | Provides 4 operating modes - constant current, resistance, voltage and power. Power: 300 watts; Voltage: 4-60V; Current: 0-60A. | in stock | ||
| Kikusui | PLZ300W | Electronic Load 4 - 60V 60A 300 Watt | Provides 4 operating modes - constant current, resistance, voltage and power. Power: 300 watts; Voltage: 4-60V; Current: 0-60A. | http://www.kandelelex.com/jpegs/kikplz300w.jpg | in stock | |
| Kikusui | PLZ-300W | Electronic Load | Provides 4 operating modes - constant current, resistance, voltage and power. Power: 300 watts; Voltage: 4-60V; Current: 0-60A. | |||
| Kikusui | PLZ303W | Electronic Load 300 Watt 1.5-120v 0-60a | The PLZ-3W Series are composed of system electronic loads used either in characteristic or lifetime tests of a variety of DC voltage sources such as switching power supplies and primary and secondary batteries, or as burn in loads. Instruments in the PLZ Series have four operation modes: "constant current", "constant resistance", "constant voltage", and "constant power". They are also available in four different power ratings, 150 W, 300 W, 600 W, and 1000 W, with a total of eight models available overall. Incorporating a high-performance current control circuit, all instruments provide highly stable, high-speed operation and offer improved operability and multi-functionality through the use of CPU control. These features allow them to simulate actual load tests of power supply units having large transitional changes in their output currents, such as printers and motors. In the constant power mode, these instruments deliver performance in carrying out load tests on alkaline and other types of batteries.
Features Constant power mode useful for battery discharge tests Setting of various conditions Variable rise/fall time function Sequence function that allows complicated current simulations Setup function and backup memories Remote sensing that compensates precisely for set values Trigger signal output useful for waveform monitoring Three-memory function and switching function Soft-start function that suppresses output voltage distortion Short-circuit function that allows instantaneous setting of the maximum current Parallel operations that offer increased current and power capacities |
in stock | ||
| Kikusui | PLZ303W | Electronic Load 300 Watt 1.5-120v 0-60a | The PLZ-3W Series are composed of system electronic loads used either in characteristic or lifetime tests of a variety of DC voltage sources such as switching power supplies and primary and secondary batteries, or as burn in loads. Instruments in the PLZ Series have four operation modes: "constant current", "constant resistance", "constant voltage", and "constant power". They are also available in four different power ratings, 150 W, 300 W, 600 W, and 1000 W, with a total of eight models available overall. Incorporating a high-performance current control circuit, all instruments provide highly stable, high-speed operation and offer improved operability and multi-functionality through the use of CPU control. These features allow them to simulate actual load tests of power supply units having large transitional changes in their output currents, such as printers and motors. In the constant power mode, these instruments deliver performance in carrying out load tests on alkaline and other types of batteries.
Features Constant power mode useful for battery discharge tests Setting of various conditions Variable rise/fall time function Sequence function that allows complicated current simulations Setup function and backup memories Remote sensing that compensates precisely for set values Trigger signal output useful for waveform monitoring Three-memory function and switching function Soft-start function that suppresses output voltage distortion Short-circuit function that allows instantaneous setting of the maximum current Parallel operations that offer increased current and power capacities |
http://www.kandelelex.com/jpegs/kikplz303w.jpg | in stock | |
| Kikusui | PLZ-303W | Electronic Load 300 Watt 1.5-120v 0-60a | The PLZ-3W Series are composed of system electronic loads used either in characteristic or lifetime tests of a variety of DC voltage sources such as switching power supplies and primary and secondary batteries, or as burn in loads. Instruments in the PLZ Series have four operation modes: "constant current", "constant resistance", "constant voltage", and "constant power". They are also available in four different power ratings, 150 W, 300 W, 600 W, and 1000 W, with a total of eight models available overall. Incorporating a high-performance current control circuit, all instruments provide highly stable, high-speed operation and offer improved operability and multi-functionality through the use of CPU control. These features allow them to simulate actual load tests of power supply units having large transitional changes in their output currents, such as printers and motors. In the constant power mode, these instruments deliver performance in carrying out load tests on alkaline and other types of batteries. And when an optional GPIB or RS-232C interface is employed, these instruments can be operated by fully programmable control.
Features Constant power mode useful for battery discharge tests Setting of various conditions Variable rise/fall time function Sequence function that allows complicated current simulations Setup function and backup memories Remote sensing that compensates precisely for set values Trigger signal output useful for waveform monitoring Three-memory function and switching function Soft-start function that suppresses output voltage distortion Short-circuit function that allows instantaneous setting of the maximum current Parallel operations that offer increased current and power capacities |
http://www.kandelelex.com/jpegs/kikplz-303w.jpg | ||
| Kikusui | PLZ603W | Electronic Load 1.5-120v 0-120a 600 Watts | http://www.kandelelex.com/jpegs/kikplz603w.jpg | |||
| Kikusui | PLZ700W | Electronic Load 700 Watts 4-60v 0-140a | The Kikusui PLZ700W is a general purpose 700 Watt Electronic Load. It operates up to 60 V and currents to 140 A. The PLZ700W has digital LED readouts of both voltage and load current plus an LED bar graph display to advise the operator of wattage being drawn. The PLZ700W features constant current and constant resistance modes of operation. Transient operation is accomplished using the internal oscillator.
Max Watts: 700. Voltage Range: 4 to 60. Current Range: 0 to 140 amps. |
http://www.kandelelex.com/jpegs/kikplz700w.jpg | ||
| Kikusui | PLZ72W | Electronic Load 72 Watt 4 - 110V DC 0 - 12A | in stock | |||
| Kikusui | PLZ-72W | Electronic Load 72 Watt 4-110v 0-12A | ||||
| Kikusui | PVS60-46 | Power Supply 0 - 60V 0 - 46A Switcher |
Voltage and current presetting 10-turn helical potentiometers are used for both voltage and current control knobs. (Voltage setting resolution: 0.02% of maximum V) Simultaneous voltage and current display Digital display shows 3.5 digits using large red LEDs Output voltage and current can be controlled using an external voltage source (0 to 5 V DC or 0 to 10 V DC). Output voltage and current can be controlled using an external resistor (0 to 5 kW or 0 to 10 kW). ON/OFF of output can be controlled using an external 0/5V signal. Height: about 88 mm high GPIB optional |
|||
| Kikusui | TOS9000 | Automatic Hipot Test System | Test Voltage: 0.02 to 5KVAC with 40mA. Insulation Resistance: 1 to 9999M ohm; Voltage: 50 to 1000V. Pass/Fail decisions with a window comparator. Up to 4 optional TOS9020 scanning units can be used for up to 16 channels. GP-IB | http://www.kandelelex.com/jpegs/kiktos9000.jpg | in stock | |
| Kikusui | TOS9020 | Voltage Scanning Unit for TOS9000 | http://www.kandelelex.com/jpegs/kiktos9020.jpg | in stock | ||
| Kilovolt | KVR20-30S | High Voltage Power Supply 20kV 30mA | in stock | |||
| Krohn-Hite | 1600 | Lin / Log Sweep Generator | Frequency: 0.2 to 3MHz in 3 bands. Waveforms: sine, square, triangle, ramp, and pulse with 14 modes of operation. Output: 20Vp-p, 10Vp-p into 50 ohm) with 60dB attenuator. | |||
| Krohn-Hite | 3202 | Variable Electronic Filter H-P L-P B-R / Frequen | Dual filter offers high-pass, low-pass, band-pass, and band-reject in the frequency range from 20 Hz to 2 MHz. Attenuation slope: 24db/oct. Hum and noise: 100uV, rms. | in stock | ||
| Krohn-Hite | 3202 | Variable Electronic Filter H-P L-P B-R / Frequen | Dual filter offers high-pass, low-pass, band-pass, and band-reject in the frequency range from 20 Hz to 2 MHz. Attenuation slope: 24db/oct. Hum and noise: 100uV, rms. | http://www.kandelelex.com/jpegs/krh3202.jpg | in stock | |
| Krohn-Hite | 3202R | Variable Electronic Filter | Dual filter offers high-pass, low-pass, band-pass, and band-reject in the frequency range from 20 Hz to 2 MHz. Attenuation slope: 24db/oct. Hum and noise: 100uV, rms. 3 inch high rack mount version. | in stock | ||
| Krohn-Hite | 3323 | Variable Electronic Filter | Frequency: 0.01Hz to 99.9KHz; Dual channel, high-pass, low-pass, band-pass, and band-reject; 24dB/octave(each channel); 0dB or 20dB pass band gain. | |||
| Krohn-Hite | 3341 | Single-Channel Electronic Filter .01Hz - 99.9KHz | The krohn Hite 3341 is a solid state, single-channel variable electronic filter that is digitally tuned over the range from .01Hz to 99.9KHz with ±2% accuracy. Pass Band Gain: 0db and 20dB. Attenuation Slope: 48dB/octive. Maximum Attenuation: 80dB. | |||
| Krohn-Hite | 3343 | Variable Electronic Filter | Dual channel unit used for high-pass, low-pass, band-pass, or band-reject filter. Frequency range: 0.01Hz to 99.9KHz. | |||
| Krohn-Hite | 3343 | Variable Electronic Filter | Dual channel unit used for high-pass, low-pass, band-pass, or band-reject filter. Frequency range: 0.01Hz to 99.9KHz. | http://www.kandelelex.com/jpegs/krh3343.jpg | ||
| Krohn-Hite | 3550 | Variable Electronic Filter | Frequency: 2Hz to 200KHz in 5 bands; Operates as a high-pass, low-pass, band-pass, or band reject filter. Slope: 24dB/octave. Butterworth or Low Q. | in stock | ||
| Krohn-Hite | 3750 | Variable Electronic Filter | Frequency: .02Hz to 20KHz; Operates as low-pass, high-pass, band-pass, or band-reject filter. Selectable slopes: 6, 12, 18, or 24dB/octave; Pass band gain: 0dB or 20dB. | in stock | ||
| Krohn-Hite | 3905A | Electronic Filter | Programmable mainframe hold up to 5 filter cards. This unit has 1)30-1 LP; 1Hz to 99KHz; 115db/oct and 1)31-1 HP; 1Hz to 99KHz; 115db/oct plug-in modules. | in stock | ||
| Krohn-Hite | 4200 | Function Generator | http://www.kandelelex.com/jpegs/krh4200.jpg | in stock | ||
| Krohn-Hite | 4200A | Test Oscillator | Frequency: 10Hz to 10MHz. Output: 10 v rms open, 5v into 50 ohm with 8 button attenuator, +20 to -50 dB, 10dB/step and fixed 1 volt into 600 ohm. Distortion: less than 0.1% from 100Hz to 100Kz. | |||
| Krohn-Hite | 4200A | Test Oscillator | Frequency: 10Hz to 10MHz. Output: 10 v rms open, 5v into 50 ohm with 8 button attenuator, +20 to -50 dB, 10dB/step and fixed 1 volt into 600 ohm. Distortion: less than 0.1% from 100Hz to 100Kz. | http://www.kandelelex.com/jpegs/krh4200a.jpg | ||
| Krohn-Hite | 5100A | Function Generator | Frequency: 0.002Hz TO 3MHz. Sine, Square, Triangle, Sawtooth, ± Ramp and pulse. Output: 20Vp-p, 10Vp-p into 50 ohm with -20, -40 dB attenuator. | |||
| Krohn-Hite | 5200A | Sweep / Pulse Function Generator | Frequency: 0.002Hz to 3MHz in 9 bands. Max Amplitude: 20v p-p (10v p-p into 50 ohm) Waveforms: sine, square, triangle, pos/neg ramp, pulse | in stock | ||
| Krohn-Hite | 6600 | Precision Phasemeter 10Hz-10MHz | Features: .1° accuracy and resolution. 10mVrms to 320Vrms input range. Accepts any waveform. Automatic voltage ranging. Analog output. | http://www.kandelelex.com/jpegs/krh6600.jpg | ||
| Krohn-Hite | 6610 | Precision Phase Meter | ||||
| Krohn-Hite | 6620 | Precision Programmable Phasemeter 10Hz - 10MHz | The Krohn-Hite Model 6620 provides precision phase measurements with a typical accuracy of 0.02° and a resolution of 0.01° over most of the frequency range. It will accept a wide range of input signal levels from 10mVrms to 320V rms and input waveforms including sine, triangle, square and pulses. A 5 digit LED display provides continuous direct readout of phase angles between 0.00° and 360.00° or ±180°. These two ranges can be manually or automatically selected.
Features Accuracy: Typically 0.02° Resolution: 0.01° GPIB Programmable Automatic Ranging Display Automatic Voltage Ranging Input Voltage Range: 10mV rms to 320V rms Deviation Measurements Accepts Any Waveform Analog Output Automatic Meter Correct (AMC) |
|||
| Krohn-Hite | 6620 | Precision Programmable Phasemeter 10Hz - 10MHz | The Krohn-Hite Model 6620 provides precision phase measurements with a typical accuracy of 0.02° and a resolution of 0.01° over most of the frequency range. It will accept a wide range of input signal levels from 10mVrms to 320V rms and input waveforms including sine, triangle, square and pulses. A 5 digit LED display provides continuous direct readout of phase angles between 0.00° and 360.00° or ±180°. These two ranges can be manually or automatically selected.
Features Accuracy: Typically 0.02° Resolution: 0.01° GPIB Programmable Automatic Ranging Display Automatic Voltage Ranging Input Voltage Range: 10mV rms to 320V rms Deviation Measurements Accepts Any Waveform Analog Output Automatic Meter Correct (AMC) |
http://www.kandelelex.com/jpegs/krh6620.jpg | ||
| Krohn-Hite | 6620A | Precision (GPIB) Programmable Phasemeter 10Hz - 10 | The Model 6620A provides precision phase measurements with a typical accuracy of 0.02° and a resolution of 0.01° over most of the frequency range. It will accept a wide range of input signal levels from 10mVrms to 320V rms and input waveforms including sine, triangle, square and pulses. A 5 digit LED display provides continuous direct readout of phase angles between 0.00° and 360.00° or ±180°. These two ranges can be manually or automatically selected.
Features Accuracy: Typically 0.02° Resolution: 0.01° GPIB Programmable Automatic Ranging Display Automatic Voltage Ranging Input Voltage Range: 10mV rms to 320V rms Deviation Measurements Accepts Any Waveform Analog Output Automatic Meter Correct (AMC) |
|||
| Krohn-Hite | 7500 | Wideband Amplifier 75 Watt DC - 1MHz | Frequency Range: DC to 1MHz. Output power (200 ohm load): 75w @ 100KHz, 40w @ 500KHz, 10w @ 1MHz. Response: ±0.1db. Distortion: >0.1%. Gain: 0 to 40db (10x, 100x fixed). Variable DC offset: 0 to 200 volts peak. Load impedance: any load within the voltage and current range of the amplifier. | in stock | ||
| Krohn-Hite | 7500 | Wideband Amplifier 75 Watt DC - 1MHz | Frequency Range: DC to 1MHz. Output power (200 ohm load): 75w @ 100KHz, 40w @ 500KHz, 10w @ 1MHz. Response: ±0.1db. Distortion: >0.1%. Gain: 0 to 40db (10x, 100x fixed). Variable DC offset: 0 to 200 volts peak. Load impedance: any load within the voltage and current range of the amplifier. | http://www.kandelelex.com/jpegs/krh7500.jpg | in stock | |
| Krohn-Hite | 7602 | Wide Band Amplifier DC-1MHz 17/34 Watts | The Krohn-Hite Models 7600 and 7602 are 17 and 34 watt, wideband power amplifiers that offer extended output power and voltage capabilities, low distortion, versatility and the latest in hybrid CMOS power operational amplifier technology with performance features not available in other power amplifiers.
MODEL 7600 The Models 7600 provide 17 watts of continuous power (34 watts at dc) and 141V rms from dc to 500kHz. The frequency response of the 7600 is ±0.1dB to 10kHz, and the distortion contributed by the amplifier is <0.01% to 5kHz and <0.3% to 100kHz. The voltage gain can be either inverting or non-inverting and has selectable ranges from 0dB-14dB, 0dB-28dB and 0dB-42dB, and is continuously variable between ranges. Other features include: modes of A, A-B and -B, common mode rejection of 80dB, input coupling of ac or dc, dc offset control that is variable from 0V to ±200V; an optional meter package that provides a meter for displaying the heat sink temperature in °C, output peak voltage and average output current. MODEL 7602 The Model 7602 provides the same performance as the Model 7600 with a differential output and is able to deliver 34 watts of continuous power (68 watts at DC) and 282V rms (800Vp-p). It can also provide plus and minus DC voltages simultaneously. Features: Output Power: 17 Watts/34Watts Output Voltage: 141V/282V rms Frequency Range: DC to 1MHz Coupling: AC or DC Gain: up to 42dB Distortion: <0.01% DC Offset: ±200V Load Impedance: Reactive and Resistive |
http://www.kandelelex.com/jpegs/krh7602.jpg | ||
| Krohn-Hite | 7602M | Wide Band Amplifier DC - 1MHz 17 / 34 Watts | The Krohn-Hite Models 7600 and 7602 are 17 and 34 watt, wideband power amplifiers that offer extended output power and voltage capabilities, low distortion, versatility and the latest in hybrid CMOS power operational amplifier technology with performance features not available in other power amplifiers.
MODEL 7600 The Models 7600 provide 17 watts of continuous power (34 watts at dc) and 141V rms from dc to 500kHz. The frequency response of the 7600 is ±0.1dB to 10kHz, and the distortion contributed by the amplifier is <0.01% to 5kHz and <0.3% to 100kHz. The voltage gain can be either inverting or non-inverting and has selectable ranges from 0dB-14dB, 0dB-28dB and 0dB-42dB, and is continuously variable between ranges. Other features include: modes of A, A-B and -B, common mode rejection of 80dB, input coupling of ac or dc, dc offset control that is variable from 0V to ±200V; an optional meter package that provides a meter for displaying the heat sink temperature in °C, output peak voltage and average output current. MODEL 7602 The Model 7602 provides the same performance as the Model 7600 with a differential output and is able to deliver 34 watts of continuous power (68 watts at dc) and 282V rms (800Vp-p). It can also provide plus and minus dc voltages simultaneously. Features: CE Output Power: 17 Watts/34Watts Output Voltage: 141V/282V rms Frequency Range: DC to 1MHz Coupling: AC or DC Gain: up to 42dB Distortion: <0.01% DC Offset: ±200V Load Impedance: Reactive and Resistive |
in stock | ||
| Krohn-Hite | 7602M | Wide Band Amplifier DC - 1MHz 17 / 34 Watts | The Krohn-Hite Models 7600 and 7602 are 17 and 34 watt, wideband power amplifiers that offer extended output power and voltage capabilities, low distortion, versatility and the latest in hybrid CMOS power operational amplifier technology with performance features not available in other power amplifiers.
MODEL 7600 The Models 7600 provide 17 watts of continuous power (34 watts at dc) and 141V rms from dc to 500kHz. The frequency response of the 7600 is ±0.1dB to 10kHz, and the distortion contributed by the amplifier is <0.01% to 5kHz and <0.3% to 100kHz. The voltage gain can be either inverting or non-inverting and has selectable ranges from 0dB-14dB, 0dB-28dB and 0dB-42dB, and is continuously variable between ranges. Other features include: modes of A, A-B and -B, common mode rejection of 80dB, input coupling of ac or dc, dc offset control that is variable from 0V to ±200V; an optional meter package that provides a meter for displaying the heat sink temperature in °C, output peak voltage and average output current. MODEL 7602 The Model 7602 provides the same performance as the Model 7600 with a differential output and is able to deliver 34 watts of continuous power (68 watts at dc) and 282V rms (800Vp-p). It can also provide plus and minus dc voltages simultaneously. Features: CE Output Power: 17 Watts/34Watts Output Voltage: 141V/282V rms Frequency Range: DC to 1MHz Coupling: AC or DC Gain: up to 42dB Distortion: <0.01% DC Offset: ±200V Load Impedance: Reactive and Resistive |
http://www.kandelelex.com/jpegs/krh7602m.jpg | in stock | |
| Krohn-Hite | MT56R | Impedance Matching Transformer For 7500 | Frequency: 30Hz to 500KHz in two ranges. Power: 75 watt. Matched Loads: 200 ohm input, 2, 8, 32, 128 ohm output. | |||
| Lambda | LB705FM | Power Supply 0 - 125V 0 - 25A 208VAC 3-Phase | in stock | |||
| Lambda | LH119FM | Power Supply 0 - 10V / 0 - 9A | in stock | |||
| Lambda | LK341FM | Power Supply 0 - 20V 0 - 13.5A | in stock | |||
| Lambda | LK342FM | Power Supply 0 - 36V 0 - 5.2A | in stock | |||
| Lambda | LK344AFM | Power Supply 0-60v 0-4A | ||||
| Lambda | LK350FM | Power Supply 0 - 20V 0 - 35A | in stock | |||
| Lambda | LK351FM | Power Supply 0-36v 0-25a | ||||
| Lambda | LK361FM0V | Power Supply 0-36v 0-48a 220 VAC | ||||
| Lambda | LK362FMOV | Power Supply 0-60v 0-25a 220 VAC | ||||
| Lambda | LLS6040 | Power Supply 0-40v 0-4A Switcher | ||||
| Lambda | LLS8018 | DC Power Supply 0-18V 0-24A Digital Switcher | in stock | |||
| Lambda | LMD15 | Power Supply 15V / 9A Modular | in stock | |||
| Lambda | LME5 | Power Supply 5V / 20A Modular | in stock | |||
| Lambda | LP531FM | Power Supply 0 - 20V 0 - 5.7A | in stock | |||
| Lambda | LP532FM | Power Supply 0 - 40V 0 - 3A | in stock | |||
| Lambda | LPD422FM | Power Supply Dual 0 - 40V 0 - 1A | Dual output CC/CV supply with auto-crossover. Continuously variable output capable of series/parallel and master/slave operation. Remote sensing and programming via resistors. | in stock | ||
| Lambda | LPD425FM | P/S Dual 0 - 250V 0 - .13A | in stock | |||
| Lambda | LPT7202FM | Triple Power Supply 0 to ±20V 0 - 1.5A / 0 - 7V | Triple output power supply to 95 watts. Front panel variable dual 20 volt supplies at 1.5 amp with a single 7 volt supply at 5.0 amp each with remote sensing capability. | in stock | ||
| Lambda | LQ-411 | Power Supply 0-20v 0-1.2A | ||||
| Lambda | LQ-524 | Power Supply 0 - 120V 0 - .5A | in stock | |||
| Lambda | LQ530 | Power Supply 0-10v 0-14A Led | ||||
| Lambda | LQ531 | Power Supply 0-20v 0-8.6a Led | ||||
| Lambda | LQ533 | Power Supply 0 - 60V 0 - 3.3A LED | in stock | |||
| Lambda | LQD422FM | Dual Power Supply 0 - 40V / 0 - 1A | in stock | |||
| Lambda | LQD424 | Dual Power Supply 0-±120v 0-.38a | ||||
| Lambda | LQD425 | Dual Power Supply 0-250v 0-.13a | ||||
| Leader | LBO-5860A | NTSC Waveform Monitor | Displays the Vertical Interval Test and Reference Signals by a front panel line selector. Lines 14 through 21 can be selected from field 1 or 2 without interference from the active portion of the video signal. Unblanking output is provided to strobe a vectorscope for polar display of the selected line. | in stock | ||
| Leader | LCD-823S-01 | Frequency / Period Counter | Frequency Range: 10Hz to 250MHz; Sensitivity: 20mVrms (50mV above 100MHz); Timebase: 10MHz, 0.03ppm; 8-digit display. | |||
| Lecroy Research | 9100 | Dual Channel Arbitrary Function Generator | User-defined waveforms at up to 200M points/s. Frequency: 0.01Hz to 25MHz with 0.035% resolution. 10V output swing into 50 ohm with 5ns risetime. Functions: sine, triangle, ramp, pulse, square, DC. GP-IB, RS-232-C and keypad control. | in stock | ||
| Lecroy Research | 9310A | Digital Oscilloscope 400 MHz 100 Ms/s | The LeCroy 9310A Digital Oscilloscope offers four channels and captures single-shot events at up to 100 MS/s and repeated signals at 10 GS/s. This unit has 50k record length allowing for outstanding horizontal resolution and extremely fast digitizing of long duration events.
Features: 4 Channels 50k Record Length Glitch, Window, Qualified, Interval, Dropout, and TV Triggers 8-bit Vertical Resolution Fully Programmable via GPIB and RS-232C Automatic Pass/Fail Testing Persistence, XY, and Roll Modes |
in stock | ||
| Lecroy Research | LC584AXL | Digital Oscilloscope 1GHz 4-Ch 8GSa/s | The LeCroy LC584AXL oscilloscope is a graph- displaying device it draws a graph of an electrical signal. In most applications, the graph shows how signals change over time: the vertical (Y) axis represents voltage and the horizontal (X) axis represents time. The intensity or brightness of the display is sometimes called the Z axis.
The LeCroy LC584AXL oscilloscope's simple graph can tell you many things about a signal, such as: the time and voltage values of a signal, the frequency of an oscillating signal, the moving parts of a circuit represented by the signal, the frequency with which a particular portion of the signal is occurring relative to, other portions, whether or not a malfunctioning component is distorting the signal, how much of a signal is direct current (DC) or alternating current (AC) and how much of the signal is noise and whether the noise is changing with time. PERFORMANCE CHARACTERISTICS OF THE LC584AXL Form Factor Benchtop W: 431 mm(17 in)H: 264 mm(10.39 in)L: 453 mm(17.83 in)Weight: 20 kg(44.09 lb) Bandwidth 1 GHz Number of Channels 4 ch Simultaneous Max Sampling Rate/ch 2 GSa/s One ch. only max. sampling rate 8 GSa/s Max. Record Length 16000000 pt/sec Min. Vertical Sensitivity 2 mV/div Maximum Vertical Sensitivity 10 V/div Rise time 350 ps Number of Bits 8 bits Input Impedance 10 MOhm (alternate) 50 Ohm Input Coupling AC,DC,GND Maximum Input Voltage 400 Vrms Maximum Input#2 (for Impedance #2) 5 Vrms Main time base - lowest 500 ps/div highest 1000 s/div Accuracy 0.001 % Trigger Source External,Internal Trigger Modes Auto,Edge,Normal,Pattern,Single,State,Stop Minimum Trigger Holdoff 2 ns Minimum Glitch Trigger 2 ns Display Type Color CRT Size 25.4 cm Display modes Auto,Normal,Single,Stop Programmability/Connectivity of the LC584AXL User Interface Proprietary Ports to Peripheral Devices GPIB,RS232C Test Pattern Storage 4 Patterns Novram data storage Yes Data Storage Type FDD |
in stock | ||
| Leeds & Northrup | 4020B | Standard Resistor 1 Ohm | ||||
| Leeds & Northrup | 4025B | Standard Resistor 10 Ohm | Reischsanstalt 10.0 ohm; ±0.003% accuracy. | in stock | ||
| Leeds & Northrup | 4030B | Standard Resistor 100 Ohm | 100.0 ohm; ±0.003% accuracy. | in stock | ||
| Leeds & Northrup | 4035B | Standard Resistor 1 kOhm | 1.0K ohm; ±0.003% accuracy. | in stock | ||
| Leeds & Northrup | 4040B | Standard Resistor 10 kOhm | 10.0K ohm; ±0.003% accuracy. | |||
| Leeds & Northrup | 4050B | Standard Resistor | 1.0M ohm; ±0.003% accuracy. | |||
| Leeds & Northrup | 4221 | Standard Resistor .1 Ohm ±.002% | in stock | |||
| Leeds & Northrup | 4221B | Standard Resistor .1 Ohm ±.002% | ||||
| Leeds & Northrup | 4222 | Standard Resistor .01 Ohm ±.002% | in stock | |||
| Linear Inst Corp | 1201-0000 | Recorder | Dual pen recorder. Uses felt tip pens. 10" wide paper. | |||
| Logimetrics | A300/C | TWT Amplifier 4 - 8GHz 20 Watt | Frequency Range GHz 4.0 - 8.0 GHz
Min. Power Out 20 Watts Min. Sat. Gain 33 dB Max. N.F. 35dB Spurious: -40dBc In/Out Impedance: 50 ohms, In/Out VSWR: 2.5:1 Max. Residual AM: 1% Maximum (-40dBc) RF Connectors: N Input: N Output: N General Prime Power: 115VAC, +/-10%, Single Phase, 50-60 Hz, 750 VA maximum Dimensions: 5-25" (133mm)H x 8-25" (210mm)W x 20-5" (521mm)D |
in stock | ||
| Logimetrics | A310/IJ | TWT Amplifier 7-18GHz 20 Watt | Frequency: 7 to 18GHz. Gain: 35dB. SMA(f) I/O connectors. 115 or 220VAC input. Rack mount. | |||
| Logimetrics | A310\S | TWT Amplifier 2-4GHz 20 Watt | ||||
| Logimetrics | A500/X | High Power Microwave Amplifier | This is a fully protected TWT amplifier. Frequency range: 8 to 12 .4 GHz; Minimum Power Output: 100 watts CW; Minimum saturated gain of 30dB. I/O Impedance: 50 ohm. | |||
| Logimetrics | A600/C | |||||
| Logimetrics | A600/L | TWT Amplifier 1-2GHz 200 Watts | Frequency: 1.0 to 2.0GHz with 30dB gain. Power: 200 watts CW. AC Input: 208VAC, 3 phase, 2.5KVA max. Options: 3 = VSWR Protection, 7 = Pulse Modulator, 10-1 = GP-IB, 14 = Preamp(less than 0dBm input for rated output). | |||
| Logimetrics | A610/X | TWT Amplifier 8-12GHz 250 Watt | 208VAC 3 phase input. | |||
| Loral | 300SBA | Systems Bus Analyzer | Designed around VME bus with all modular functions. Can be connected to a host computer through either a GPIB or an RS-232 interface. Features: Centronics 101A compliance; VME bus electrical specification compliance; High-speed direct memory access by a host computer through the use of a Symbolic DMA Language; English-language commands; Interface protection. | in stock | ||
| Marconi | 2019 | AM/FM Signal Generator 80KHz - 1040MHz | Synthesized generator covers 80KHz to 1040MHz with 10Hz resolution. RF Output: -127 to +13dBm with .1dB resolution and ±1dB accuracy. FM: 0-100KHz peak deviation. AM: 0-99% in 1% steps. Continuous LCD readouts of frequency, modulation, level. | in stock | ||
| Marconi | 2022 | AM/FM Signal Generator 10KHz - 1GHz | Frequency: 10KHz to 1GHz with 10Hz resolution(7-digit LCD). RF Output: -127 to +6dBm with ±2dB accuracy and .1dB resolution(4-digit LCD). Internal AM/FM/PM. 50 watt reverse power protection. Optional GP-IB. | in stock | ||
| Marconi | 2022A | AM/FM Signal Generator 10KHz-1GHz | Frequency: 10KHz to 1GHz with 10Hz resolution(7-digit LCD). RF Output: -127 to +6dBm with ±2dB accuracy and .1dB resolution(4-digit LCD). Internal AM/FM/PM. 50 watt reverse power protection. Optional GP-IB. | http://www.kandelelex.com/jpegs/mar2022a.jpg | in stock | |
| Marconi | 2022C | AM/FM Signal Generator 10KHz-1GHz | Frequency: 10KHz to 1GHz with 10Hz resolution(7-digit LCD). RF Output: -127 to +13dBm with ±2dB accuracy and .1dB resolution(4-digit LCD). Internal AM/FM/PM. 50 watt reverse power protection. Optional GP-IB. | http://www.kandelelex.com/jpegs/mar2022c.jpg | ||
| Marconi | 2022D | FM-AM Signal Generator 10KHz-1GHz +13dBm GPIB | The Marconi 2022D is a lightweight synthesized signal generator having a frequency range of 10 kHz to 1 GHz and providing comprehensive amplitude, frequency and phase modulation facilities with an RF output level range of -127 dBm to +13 dBm. The 2022D is designed to cover a wide range of RF applications in development, production and maintenance environments. | |||
| Marconi | 2022E | AM/FM Signal Generator 10KHz-1GHz | Frequency: 10KHz to 1GHz with 10Hz resolution(7-digit LCD). RF Output: -127 to +13dBm with ±2dB accuracy and .1dB resolution(4-digit LCD). Internal AM/FM/PM. 50 watt reverse power protection. Optional GP-IB. | in stock | ||
| Marconi | 2022E | AM/FM Signal Generator 10KHz-1GHz | Frequency: 10KHz to 1GHz with 10Hz resolution(7-digit LCD). RF Output: -127 to +13dBm with ±2dB accuracy and .1dB resolution(4-digit LCD). Internal AM/FM/PM. 50 watt reverse power protection. Optional GP-IB. | http://www.kandelelex.com/jpegs/mar2022e.jpg | in stock | |
| Marconi | 2023A | Signal Generator 9KHz-1.2GHz | Frequency: 9KHz to 1.2GHz with 1Hz resolution and time base accuracy(±5 x 10(7)). Output: -140dBm to +13dBm with .1dB resolution and ±.8dB accuracy. Modulation: AM,FM,Phase,Pulse and FSK. RPP to 50W. RS-232 and GPIB control. | |||
| Marconi | 2023B 105 | Signal Generator 9KHz - 2.05GHz SINAD External Mo | With its level of performance, this compact general purpose signal generator delivers outstanding value for money.
Wide frequency coverage: 9 kHz to 2.05 GHz Excellent spectral purity Outstanding phase noise performance Linear and logarithmic sweep mode Sine, triangular and square wave two-tone modulation source RS232 and GPIB control Comprehensive modulation: AM, FM, OM, Pulse & FSK 3.9 kHz Bessel filtered FSK Optional +25 dBm RF output SINAD Measurement Option RPP to 50 W |
http://www.kandelelex.com/jpegs/mar2023b 105.jpg | in stock | |
| Marconi | 2024 | Signal Generator | The IFR / Marconi 2024 AM-FM Signal Generator is portable and lightweight, offering carrier frequencies from 9KHz to 2.4GHz.
Frequency: 9 kHz to 2.4 GHz with 1Hz resolution Linear and logarithmic sweep mode Sine, triangular and square wave two tone modulation source RS232 and GPIB control Comprehensive modulation: AM, FM, fM, Pulse & FSK 3.9 kHz Bessel filtered FSK Optional +25 dBm RF output SINAD Measurement Option RPP to 50 W |
|||
| Marconi | 2024 | Signal Generator | The IFR / Marconi 2024 AM-FM Signal Generator is portable and lightweight, offering carrier frequencies from 9KHz to 2.4GHz.
Frequency: 9 kHz to 2.4 GHz with 1Hz resolution Linear and logarithmic sweep mode Sine, triangular and square wave two tone modulation source RS232 and GPIB control Comprehensive modulation: AM, FM, fM, Pulse & FSK 3.9 kHz Bessel filtered FSK Optional +25 dBm RF output SINAD Measurement Option RPP to 50 W |
http://www.kandelelex.com/jpegs/mar2024.jpg | ||
| Marconi | 2024 04 | Signal Generator | The IFR / Marconi 2024 AM-FM Signal Generator is portable and lightweight, offering carrier frequencies from 9KHz to 2.4GHz.
Frequency: 9 kHz to 2.4 GHz with 1Hz resolution Linear and logarithmic sweep mode Sine, triangular and square wave two tone modulation source RS232 and GPIB control Comprehensive modulation: AM, FM, fM, Pulse & FSK 3.9 kHz Bessel filtered FSK Optional +25 dBm RF output SINAD Measurement Option RPP to 50 W |
http://www.kandelelex.com/jpegs/mar2024 04.jpg | ||
| Marconi | 2030 | Signal Generator 10KHz To 1350MHz | Frequency: 10KHz to 1.35GHz with .1Hz resolution (11 digits). Amplitude: -144 to +13dBm with .1Hz resolution and ±1dB accuracy. Modulation Oscillator: .1Hz to 500KHz. Wideband FM with 10MHz bandwidth. GP-IB. Option 1 provides second modulation oscillator. | http://www.kandelelex.com/jpegs/mar2030.jpg | ||
| Marconi | 2031 | Signal Generator 10KHz-2.7GHz | Dot matrix, LCD displays all status information. Frequency: 10KHz to 2.7GHz with .1Hz resolution and 11-digit readout. Output: +13 to -144dBm with .1dB resolution and ±1dB accuracy on 4-digit readout. AM/FM/PM, sweep, GP-IB. Call for availability of options: 01 provides second modulation oscillator; 02 provides pulse modulation. | http://www.kandelelex.com/jpegs/mar2031.jpg | ||
| Marconi | 2031 01-02-102 | Signal Generator 10KHz - 2.7GHz Dual Modulation Os | The Marconi 2031 signal generator offers increased flexibility with combinations of frequency, phase, amplitude, and pulse modulation over the 10 kHz to 2.7 GHz frequency range. This instrument is suitable for a wide variety of applications ranging from RF component characterization to radio communications system testing. Microprocessor control coupled with a large screen dot matrix display provides ease of use via menu driven displays. Set up time is further reduced by recalling previously stored instrument settings from the non-volatile memory. Remote programming via the GPIB is provided as a standard feature, allowing the instruments to be included in automatic test systems. This unit also features 0.1 Hz frequency resolution, 0.1 Hz to 500 kHz modulation oscillator, wideband FM with 10 MHz bandwidth, and comprehensive sweep capabilities.
Option 001 - Second internal modulation oscillator Option 002 - Pulse Modulation |
in stock | ||
| Marconi | 2041 | Low Noise Signal Generator 10KHz-2.7GHz | Frequency: 10KHz to 2700MHz with .1Hz resolution. Output: +13 to -144dBm with .1dB resolution and ±1dB accuracy. Phase Noise: -140dBc/Hz at 1GHz. Residual FM: .3Hz rms at 1GHz. Spurious signals: -90dBc non-harmonics. Comprehensive modulation modes and sweep capabilities. Options: 001-Dual Modulation Oscillator...add $225.; 002-Pulse Modulation...add $1600.; 006-Avionics(ILF & VOR)...add $1600. | http://www.kandelelex.com/jpegs/mar2041.jpg | ||
| Marconi | 2051 | Digital and Vector Signal Generator 10KHz - 2.7GHz | The Marconi 2051 digital and vector signal generator covers the frequency range 10kHz to 2.7 GHz. This instrument is suitable for a wide range of applications including the testing of new digital communication systems. 2050 series signal generators have a large screen dot matrix display with softkey function selection which allows flexibility of operation. Hardkey and data entry key together with a rotary control knob are also provided. The output may be modulated using ΦM, FM, AM, IQ vector or complex digital modulation. Pulse modulation is optional.
Features: PSK, FSK, QAM, GMSK I and Q modulation to 10 MHz (1 dB bw.) External digital data input Internal PRBS data source Excellent accuracy and stability Envelope control for RF bursts Programmable channel filter characteristics Variable data rate control NADC, PDC, GSM, TETRA plus others Wide band DCFM for fast FSK Baseband I & Q outputs Electronic attenuator option |
http://www.kandelelex.com/jpegs/mar2051.jpg | ||
| Marconi | 2305 | Modulation Meter | Frequency Range: 50KHz to 2.32GHz with 8-digit display. Auto or manual tuning with -15dBm sensitivity at 2GHz(-25dBm at lower frequencies). Measures FM, 500KHz peak deviation at 30Hz to 275KHz rates; AM, 99.9% at 30Hz to 50KHz rates; PM, 500 radians up to 1KHz. Basic accuracy: 0.5%. Also measures frequency and power. GP-IB programming optional. | in stock | ||
| Marconi | 2957B | Cellular Service Monitor | Portable radio test set with full-function cellular test, system simulation for mobile testing, go/no-go test sequences, and automatic RF tests. Wideband data displays show digital word and bit errors. Disk drive interface for storage of user-defined test programs. RD-232, parallel printer and option GP-IB interfaces. | |||
| Marconi | 2960B | Cellular Service Monitor | Combined base station simulation and mobile radio cellular and trunking test system with analog and digital software. Similar to 2957B, but with the capacity to support up to five different digital cellular types. | in stock | ||
| Marconi | 6057B/1 | 4 - 8GHz Signal Source | Frequency range: 4.0 to 8.0GHz with .007% stability and ±1% accuracy. RF Output: 5mW with 20dB level control. 1KHz internal AM. Small size: 4" x 8" x 12"; 8.75 Lbs. | in stock | ||
| Marconi | TF2304 | AM/FM Modulation Meter | Covers 9 MHz to 1000 MHz with completely automatic tuning and level setting. Measures FM deviation in 8 ranges from 1.5 to 150 KHz, and AM in 3 ranges; 10, 30 and 100%. Compact size and light weight. RF and IF outputs | in stock | ||
| Marconi | TF2304 | AM/FM Modulation Meter | Covers 9 MHz to 1000 MHz with completely automatic tuning and level setting. Measures FM deviation in 8 ranges from 1.5 to 150 KHz, and AM in 3 ranges; 10, 30 and 100%. Compact size and light weight. RF and IF outputs | http://www.kandelelex.com/jpegs/martf2304.jpg | in stock | |
| Maury Microwave | J255C9 | WG Attenuator 44GHz | in stock | |||
| Maury Microwave | J255D9 | WG Attenuator 44GHz | in stock | |||
| Meiji | EMZ | Zoom Stereo Microscope | EMZ-2
Body: Binocular, rotatable 360°. Zoom Ratio: 6.5:1. Zoom Range: 0.7x - 4.5x. Zoom Control: Graduated knurled ring. Magnification: 7x - 45x (with 10x eyepieces). Field of View: 32mm - 5.1mm. Working distance: 93mm. Eyetube Inclination: 45°. Interpupillary Distance Adjustment: 54mm - 75mm. Dioptric Adjustment: Dual (+/- 5 diopters). Extended Magnification Range: 2.1x - 270x. Extended Working Distances: 34mm - 251mm.(with supplemental objectives and eyepieces). System includes: POD, 10X w.f. eyepieces, boom-stand, and mount. |
http://www.kandelelex.com/jpegs/meiemz.jpg | in stock | |
| Microdot | 186 | Power Oscillator Plug-In 200 - 500MHz 50 Watt | Used in 445 mainframe, provides 200 to 500MHz, 50 watt output. | in stock | ||
| Microdot | 187 | Power Oscillator Plug-In 500 - 1000MHz 50 Watt | Used in 445 mainframe, provides 500 to 1000MHz, 50 watt output. | in stock | ||
| Microdot | M185 | Power Oscillator Plug-in 50-200MHz 50 Watt | Used with 445 mainframe | |||
| Microdot | M187 | RF Oscillator Plug-In | Frequency: 500 to 1000MHz. Power output: 50 watts. | in stock | ||
| Microdot | M445 | Power Oscillator Mainframe | Requires plug-in oscillators to cover the frequency range from 2MHz to 2.5GHz. Maximum power is 50 watts. 1Khz internal square wave modulation. | |||
| Microlab (FXR) | C601B | WG to Coax Adapter 5.85 - 8.2GHz | in stock | |||
| Microlab (FXR) | CB-17N | Coaxial Directional Coupler 200-400MHz 10dB N(f) 2 | in stock | |||
| Microlab (FXR) | CB-28N | Directional Coupler .4 - .8GHz 20dB | in stock | |||
| Microlab (FXR) | CB-68N | Directional Coupler 2 - 4GHz 20dB | in stock | |||
| Microlab (FXR) | HR-B23 | Coaxial DC Block | in stock | |||
| Microlab (FXR) | L600C | WG To Coax Adapter 1.12-1.7GHz | ||||
| Microlab (FXR) | N414A | Frequency Meter 3.95-11GHz .1% Acc | ||||
| Microlab (FXR) | R601C | WG To Coax Adapter 1.7-2.6GHz | ||||
| Microlab (FXR) | X601B | WG to Coax Adapter 8.2 - 12.4GHz | in stock | |||
| Micronetics, Inc | NSI-2640W | Noise Source 26 - 40GHz | Waveguide noise source for use with HP 8970A/B noise figure meter. Frequency: 26.5 to 40GHz. DC Input: +28V. | in stock | ||
| Microtech | 219787 | K-Band Waveguide Magic Tee | ||||
| Microwave Development Co | 22750E-NM | Waveguide To Coax Adapter Double-ridge Wrd750 | 7.5 to 18GHz, N(m) connector high power end launch. | |||
| Microwave Devices | 636N | RF Load DC-3GHz 600 Watt | in stock | |||
| Microwave Logic / Tektronix | SJ-300A | SDH/Sonet Analyzer | Portable analyzer with exhaustive SONET, SHD jitter and wander features on systems up to 622 Mbps. Also generates and analyzes BITS/SETS wander. | |||
| Microwave Power Devices (MACOM) | EWAL1050-12 | Dual RF Amplifier System | System includes two separate 100 watt amplifiers and a separate model HEPS-30-70 power supply to power both amplifiers. Frequency Range: 100 to 500MHz. Output: 100 watts CW each amplifier with less then 1mW(0dBm) input. Features: All solid state, Low distortion AB linear, Fully protected, and Graceful degradation. May be sold as two seperate amplifiers with choice of power supplies. | |||
| Microwave Power Devices (MACOM) | EWAL-1235 | RF Amplifier 2 - 30MHz 450 Watt | This solid-state amplifier has a seperate power supply made for 208V, 3 ph, 400Hz AC input. The amplifier section requires 28 volts dc at 30 amps. | in stock | ||
| Microwave Power Devices (MACOM) | LAB1-055-10E | RF Amplifier 10 - 500MHz 10 Watt | Frequency: 10 to 500MHz. Output: 10 watts, 40dBm@1dB Compression. Small gain flatness: ±2dB. | in stock | ||
| Microwave Power Devices (MACOM) | LAB1-510-30G | RF Amplifier 500 - 1000MHz 30 Watt | Frequency: 500MHz to 1GHz. Output Power: 30 watts, with ±2dB flatness and 50dB gain. | http://www.kandelelex.com/jpegs/mpdlab1-510-30g.jpg | in stock | |
| Microwave Power Devices (MACOM) | LAB3-105-75K | RF Amplifier 100 - 500MHz 75 Watt | Frequency: 100-500MHz Power: 75 watts | in stock | ||
| Microwave Power Devices (MACOM) | LAB3-510-20D | RF Amplifier .5 - 1GHz 20 Watt | in stock | |||
| Microwave Power Devices (MACOM) | LAB3-510-4 | RF Amplifier 500MHz - 1GHz 4 Watt | in stock | |||
| Microwave Power Devices (MACOM) | LAB3-714-3C | RF Amplifier 3 Watt 700 - 1400MHz | Solid state amplifier has 3 watt output with a frequency range from 700 to 1400MHz. | in stock | ||
| Microwave Power Devices (MACOM) | LAB3-714-6E | RF Amplifier .7 - 1.4GHz 6 Watts | in stock | |||
| Microwave Power Devices (MACOM) | PWAL1014-12-890 | RF Amplifier 1085 - 1415MHz 100 Watt | Frequency: 1085 to 1415MHz. Output power: 100 watts. 1mW (0dBm) input for full power output. Circulator protected. | in stock | ||
| Microwave Power Equipment | PAS-47-0-500-1000 | RF Amplifier 500 - 1000MHz 50 Watt Class AB | in stock | |||
| Microwave Power Equipment | PAS-53-0-250-500 | RF Amplifier 250-500MHz 200 Watt Class Ab | ||||
| Microwave Semiconductor Corp | MC5048P | Noise Source | in stock | |||
| Midwest Microwave | 1043 | Fixed Attenuator 60dB DC - 18GHz SMA | in stock | |||
| Midwest Microwave | 1072 | Step Attenuator 0-9dB DC-12GHz SMA (f) | ||||
| Midwest Microwave | 3551 | Attenuator Set 3 6 10 20dB | Type N. DC to 18GHz | in stock | ||
| Midwest Microwave | 391-40 | Fixed Attenuator | ||||
| Midwest Microwave | 527-13 | Coaxial Attenuator DC - 12.4GHz 13dB 20 Watt SMA ( | Model #: ATT-0527-13-SMA-07
Category: Medium Power SMA Fixed Attenuators Body: Standard Interfaces: SMA/SMA Interface Genders: Male / Female Power: 20 Watt Attenuation: 13 dB Frequency Range: DC to 12.4 Ghz Finish/Color: Anodized |
in stock | ||
| Midwest Microwave | 527-40 | Fixed Attenuator DC - 12GHz 40dB SMA | in stock | |||
| Midwest Microwave | 528-30 | Coaxial Attenuator DC - 12.4GHz 30dB 20 Watt N(m | Model #: ATT-0528-30-OOO-07
Category: Medium Power Type N Fixed Attenuators Body: Standard Interfaces: N/N Interface Genders: Male / Female Power: 20 Watt Attenuation: 30 dB Frequency Range: DC to 12.4 Ghz Finish/Color: Anodized |
in stock | ||
| Midwest Microwave | TRM-2098-M0-NNN-07 | Coaxial Termination DC - 18GHz 10 Watt N(m) Connec | Model #: TRM-2098-M0-NNN-07
Category: Medium Power Type N Terminations Body: Standard VSWR: LOW Interfaces: Type N Interface Genders: Male Power: 10 Watt Frequency Range: DC to 18 Ghz Finish/Color: Anodized Delivery: Stk-30 days |
in stock | ||
| Military | 48127 | R-Band Waveguide Horn Antenna 26.5 - 40GHz | Round flange UG-381/U. Similar to Narda V637. | in stock | ||
| Mini-circuits Lab | TIA-1000-1R8 | RF Amplifier .5 - 1000MHz 1.8 watts | Features
Frequency: 0.50 to 1000MHz Flatness: ±2.0 dB Gain: 35dB Power: +32dBm min (+35dBm typical); 1.8 watts linear(4 watts saturated) Instrument model with built-in power supply, 110V/220V operation High power output at 3.5dB compression, 37dBm typ. High gain, 38 dB typ. High reverse isolation, 80 dB typ. 100% burn-in at +25°C, 48 hrs Thermally self-protected, LED indicator |
|||
| Mini-circuits Lab | TIA-900-10 | RF Amplifier 100-900MHz 10 Watts | Features:
Wide bandwidth: 100-900MHz Built-in power supply,110/220V operation Power output(at 3.5 dB compression): +40dB min.(45 dBm typical) Gain: 28dB min.(34 dB typical) Flatness: ±2.5dB VSWR: 2.5:1 in / out High reverse isolation, 80 dB typical 100% Burn-In at +25oC, 48 hours Thermally self-protected, led indicator |
|||
| Motorola | PAA0180-40-50LAM | RF Amplifier 800 - 1000MHz 100 Watt | in stock | |||
| Motorola | R1100A | FSK Code Synthesizer | Generates a number of single and dual tone sequential codes with stored timing intervals as well as a wide variety of selective signalling codes: DPL, Inverted DPL, Tone Remote and DTMF. May also be used as a 10Hz to 9.999 KHz general purpose audio oscillator. Digital display and AC power. | http://www.kandelelex.com/jpegs/motr1100a.jpg | in stock | |
| Narda | 1069-10 | WG Directional Coupler 12 - 18GHz 10dB | in stock | |||
| Narda | 1080 | X-band Narrow Wall Coupler 40dB | ||||
| Narda | 175 | Coaxial Pick Up Horn Antenna 8.5 - 9.6GHz N | in stock | |||
| Narda | 23940 | Coaxial Directional Coupler 1-2.6GHz 10dB SMA(f) | in stock | |||
| Narda | 26773 | High Power Directional Coupler 2-8GHz 40dB 400W av | The Narda 26773 is a high power directional coupler. Covers 2 to 8GHz, 40dB ccoupling. Power Handling: 400 watts average, 5KW peak. The input connector is a TNC(m) and the output connectors a type N(f). Similar to Narda 27005-40. | in stock | ||
| Narda | 27000-30 | High Power Directional Coupler 2-18GHz 30dB 400 Wa | THe Narda 27000-30 features 400 watt average and 3kw peak rating; Low-loss air dielectric.
Specifications: 30dB coupling, ±1.4dB Power Handling: 400W average, 3KW peak Directivity: 12dB 2-15GHz, 10dB 15-18GHz Insertion Loss: .5dB Connectors: N(m) input, N(f) output main and coupled |
|||
| Narda | 27000-30 | High Power Directional Coupler 2-18GHz 30dB 400 Wa | THe Narda 27000-30 features 400 watt average and 3kw peak rating; Low-loss air dielectric.
Specifications: 30dB coupling, ±1.4dB Power Handling: 400W average, 3KW peak Directivity: 12dB 2-15GHz, 10dB 15-18GHz Insertion Loss: .5dB Connectors: N(m) input, N(f) output main and coupled |
http://www.kandelelex.com/jpegs/nar27000-30.jpg | ||
| Narda | 27000-40 | High Power Attenuator 2-18GHz 40dB 400 Watt 3kwpea | ||||
| Narda | 27004-30 | High Power Directional Coupler 6-18GHz | The Narda Microwave 27004-30 is a high power directional coupler. Frequency Range: 6 to 18GHz. Coupling: 30dB, ±1.0dB. Power Handling: 400 watt average; 3KW peak. Directivity: 12dB to 15GHz, 10dB 15-18GHz. Insertion loss: .5dB. Connectors: main i/o TNC(m-f), SMA(f) coupled output. | |||
| Narda | 27005SC-40 | Directional Coupler 2 - 8GHz 40dB 1kW | in stock | |||
| Narda | 27487-30 | High-power Directional Coupler 6 - 18GHz 400 Watt | in stock | |||
| Narda | 3000-10 | Coaxial Directional Coupler 225 - 460MHz | in stock | |||
| Narda | 3000-10 | Coaxial Directional Coupler 225 - 460MHz | http://www.kandelelex.com/jpegs/nar3000-10.jpg | in stock | ||
| Narda | 3000-20 | Coaxial Directional Coupler 225 - 460MHz | Frequency: .225 to .460GHz; Type N connectors; Available in 10, 20, or 30dB coupling values. | in stock | ||
| Narda | 3000-20 | Coaxial Directional Coupler 225 - 460MHz | Frequency: .225 to .460GHz; Type N connectors; Available in 10, 20, or 30dB coupling values. | http://www.kandelelex.com/jpegs/nar3000-20.jpg | in stock | |
| Narda | 3000-30 | Directional Coupler 225 - 460MHz | Frequency: .225 to .460GHz; Type N connectors; Available in 10, 20, or 30dB coupling values. | http://www.kandelelex.com/jpegs/nar3000-30.jpg | in stock | |
| Narda | 3001-20 | Directional Coupler 460 - 950MHz | Frequency: .46 to .95MHz; Type N connectors; Available in 10, 20, and 30dB coupling values. | http://www.kandelelex.com/jpegs/nar3001-20.jpg | in stock | |
| Narda | 3002-20 | Directional Coupler .95 - 2GHz 20dB | in stock | |||
| Narda | 3003-20 | Coaxial Directional Coupler 2 - 4GHz | in stock | |||
| Narda | 3003-30 | Directional Coupler 2 - 4GHz 30dB N | in stock | |||
| Narda | 3004-10 | Directional Coupler 4 - 10GHz 10dB | in stock | |||
| Narda | 3004-20 | Directional Coupler 4 - 10GHz 20dB | Frequency: 4 to 10GHz; Type N connectors; Available in 10, 20 and 30dB coupling values. | in stock | ||
| Narda | 3010-500 | Low Pass Filter 500MHz Cutoff | in stock | |||
| Narda | 3020 | Bi-Directional Coupler 50 - 1000MHz | in stock | |||
| Narda | 3020A | Bi-Directional Coupler 50MHz - 1GHz 20dB | 50MHz to 1GHz; 35dB directivity; 20dB coupling nominal; 500 watts average power; 10kW peak power; Primary line connectors are N(M/F), secondary line connectors are N(F/F); Dual reflectometer type. | in stock | ||
| Narda | 3020A | Bi-Directional Coupler 50MHz - 1GHz 20dB | 50MHz to 1GHz; 35dB directivity; 20dB coupling nominal; 500 watts average power; 10kW peak power; Primary line connectors are N(M/F), secondary line connectors are N(F/F); Dual reflectometer type. | http://www.kandelelex.com/jpegs/nar3020a.jpg | in stock | |
| Narda | 3022 | Bi-Directional Coupler 1 - 4GHz | Model Number 3022
Frequency (Low) in MHz 1,000 Frequency (High) in MHz 4,000 Nominal Coupling dB 20 Directivity dB (min) 30 (1-3 GHz ) / 27 (3-4 GHz) VSWR Primary Line power 1.15 VSWR Secondary Line Power 1.15 Equivalent Residual VSWR (max) 1.09 Absolute Calibration Accuracy dB (per 10 dB step) +/-0.1 Insertion Loss 0.3 Tracking dB 0.3 Max Deviation from Nominal dB +/-1.0 Power AVG (Incident in W) 500 Power AVG (Reflected in W) 500 Power (Peak) in kW 10 Weight (max) in lbs 1.9 Weight (max) in kg 0.7 Primary Connectors: 1 female, 1 male, Type N Secondary Connectors: 2 female, Type N |
in stock | ||
| Narda | 3022 | Bi-Directional Coupler 1 - 4GHz | Model Number 3022
Frequency (Low) in MHz 1,000 Frequency (High) in MHz 4,000 Nominal Coupling dB 20 Directivity dB (min) 30 (1-3 GHz ) / 27 (3-4 GHz) VSWR Primary Line power 1.15 VSWR Secondary Line Power 1.15 Equivalent Residual VSWR (max) 1.09 Absolute Calibration Accuracy dB (per 10 dB step) +/-0.1 Insertion Loss 0.3 Tracking dB 0.3 Max Deviation from Nominal dB +/-1.0 Power AVG (Incident in W) 500 Power AVG (Reflected in W) 500 Power (Peak) in kW 10 Weight (max) in lbs 1.9 Weight (max) in kg 0.7 Primary Connectors: 1 female, 1 male, Type N Secondary Connectors: 2 female, Type N |
http://www.kandelelex.com/jpegs/nar3022.jpg | in stock | |
| Narda | 3024 | Bi-Directional Coupler 4 - 8GHz 20dB | in stock | |||
| Narda | 3029 | Quadrature Hybrid Coupler | Frequency: 215 to 450MHz; 4 port; 90°;-3dB. Used to combine 2 amplifiers. | in stock | ||
| Narda | 3031 | Coaxial Hybrid Junction .46-.95GHz 20dB Min Isolat | in stock | |||
| Narda | 3033 | Coaxial Hybrid Junction | 2-4z, 20dB min. isolation, 3dB nominal coupling. | in stock | ||
| Narda | 3034 | Coaxial Hybrid 4-8GHz 3dB Coupling 200W | The Narda 3034 is a type N coaxial 90 degree Hyberd.
Frequency: 4 to 8 GHz Coupling(nominal): 3dB(+.3 -0) VSWR(max): 1.3:1 Isolation(min): 18dB Phase Balance: 10 degrees Power: 200 watts average; 5KW peak Type N(f) connectors |
in stock | ||
| Narda | 3039-20 | Coax Directional Coupler 125 - 250MHz 20dB | in stock | |||
| Narda | 3039-20 | Coax Directional Coupler 125 - 250MHz 20dB | http://www.kandelelex.com/jpegs/nar3039-20.jpg | in stock | ||
| Narda | 3040-30 | Coaxial Directional Coupler 240-500MHz 30dB 20dB C | ||||
| Narda | 3041-10 | Coaxial Directional Coupler .5-1GHz 10dB 200W N(f) | in stock | |||
| Narda | 3042-10 | Coaxial Directional Coupler .95-2GHz 10dB N(f) | in stock | |||
| Narda | 3042-20 | Coaxial Directional Coupler .95-2GHz 20dB 200W N( | in stock | |||
| Narda | 3042B-10 | Coaxial Directional Coupler .92-2.2GHz 10dB N(f) | in stock | |||
| Narda | 3042B-20 | Directional Coupler .92 - 2.2GHz 20dB | http://www.kandelelex.com/jpegs/nar3042b-20.jpg | in stock | ||
| Narda | 3043-10 | Coax Dir. Coup. 2 - 4 GHz 10dB | in stock | |||
| Narda | 3043-20 | Coaxial Directional Coupler 2 - 4 GHZ | in stock | |||
| Narda | 3043B-10 | Directional Coupler 1.7 - 4.2GHz 10dB | in stock | |||
| Narda | 3043B-20 | Directional Coupler 1.7 - 4.2GHz 20dB | in stock | |||
| Narda | 3043B-30 | Directional Coupler 1.7 - 4.2GHz | in stock | |||
| Narda | 3044-10 | Directional Coupler 4 - 8GHz | in stock | |||
| Narda | 3044-20 | Coaxial Directional Coupler 4 - 8GHz 20dB | in stock | |||
| Narda | 3044-30 | Coaxial Directional Coupler 4 - 8GHz 30dB | in stock | |||
| Narda | 3044B-20 | Directional Coupler 3.7 - 8.3GHz 20dB | in stock | |||
| Narda | 3044B-30 | Directional Coupler 3.7 - 8.2GHz 30dB | in stock | |||
| Narda | 319B | High Power Load | in stock | |||
| Narda | 320 | Waveguide High Power Termination X-Band 8 - 12GHz | in stock | |||
| Narda | 320B | X-band Termination 500 Watt | ||||
| Narda | 321B | TERMINATION HIGH POWER | in stock | |||
| Narda | 368BNF | Coaxial Termination 500 Watt, 2-18GHz | ||||
| Narda | 368BNM | High Power Coaxial Termination 2-18GHz 500W avg N | The Narda 368BNM is a high power ternmiation. Frequency: 2 to 18GHz. Power: 500 watts average; 5KW peak. Type N male connector. | |||
| Narda | 368NF | Coaxial Termination 2 - 12.4GHz 500 watt 5kW Pe | ||||
| Narda | 369NM | Coaxial Load .7-12.4GHz 175 Watts | ||||
| Narda | 370BNM | Coaxial Termination 50 Ohm DC-18GHz 5 Watt N | in stock | |||
| Narda | 3712 | Variable Precision Attenuator 1-2GHz 6~100dB | in stock | |||
| Narda | 376BNF | Coaxial Termination DC - 12.4GHz 40 Watt N(f) | in stock | |||
| Narda | 378NM | Termination DC-18GHz | ||||
| Narda | 4014C-6 | SMA Directional Coupler 4 - 8GHz 6dB | in stock | |||
| Narda | 4203-10 | Directional Coupler 2 - 18GHz SMA | in stock | |||
| Narda | 4314-2 | SMA Power Splitter 4 - 8GHz 2 Way | in stock | |||
| Narda | 4456-2 | Power Divider 2-18GHz SMA | ||||
| Narda | 4503 | Crystal Detector .01-18GHz SMA-BNC | ||||
| Narda | 4609 | WG(12 - 18GHz) to Coaxial Adapter (sma) | in stock | |||
| Narda | 4779-3 | SMA Fixed Attenuator DC - 18GHz 2 Watt | http://www.kandelelex.com/jpegs/Nar4779-3.jpg | |||
| Narda | 4917 | Broadband Isolator 18 - 26GHz SMA 17dB 3w | in stock | |||
| Narda | 5293 | Directional Coupler 1 - 12.4GHz 10dB | in stock | |||
| Narda | 60114 | Amplifier 3.75 - 8GHz | Small unit with power supply. | in stock | ||
| Narda | 609 | WG(12.4 - 18GHz) to Coaxial Adapter (n) | in stock | |||
| Narda | 613A | WG to Coax(n-f) Adapter (c-band 3.95 - 5.85GHz) | in stock | |||
| Narda | 615 | WG - Coax Adapter Ls-band 1.7-2.6GHz Wr-430 | ||||
| Narda | 640 | WG Standard Gain Horn (x-band 8.2-12.4 GHz) | Model Number 640
Frequency (Low) in MHz 8,200 Frequency (High) in MHz 12,400 Band X* Waveguide Size WR-90 Input Cover Flange Equivalent UG-135/U VSWR (max) 1.15 |
|||
| Narda | 643 | Standard Gain Horn (3.95-5.85GHz) | ||||
| Narda | 644 | WG Standard Gain Horn (s-band, 2.6-3.95GHz) | ||||
| Narda | 7000A | Microwave Multimeter | Portable test unit together with the 7202 and 7206 measures: reflection coefficient, power, VSWR, return loss, insertion loss, gain, isolation and DC volts. Frequency range: 10MHz to 18GHz. Power range: -50 to +13dBm. Auto-ranging. GP-IB. | |||
| Narda | 719-10 | WG Fixed Attenuator (12 - 18GHz 10dB) | in stock | |||
| Narda | 729 | WG Fixed Attenuator (12 - 18GHz 20dB) | in stock | |||
| Narda | 757B-20 | Fixed Attenuator DC - 12.4GHz 20dB N | in stock | |||
| Narda | 766-30 | 20 Watt Attenuator 30dB DC-4GHz | ||||
| Narda | 768-10 | Fixed Coaxial Attenuator DC-11GHz 20 Watts 10dB N | Features
*Frequency Range: DC to 11GHz *Attenuation: 10dB *VSWR: 1.3 *Power: 20 watts *Input Connector: N-Type (M) *Output Connector: N-Type (F |
in stock | ||
| Narda | 768-20 | Fixed Coaxial Attenuator | The Narda 768-20 is a type N, high power, bi-directional 20 dB fixed coaxial attenuator. It has a broad frequency range (DC - 11 GHz), high power (20 Watts), small in size and stainless steel connectors. | in stock | ||
| Narda | 768-30 | Coax Attenuator DC-11GHz 20 Watt | ||||
| Narda | 774-20 | Fixed Attenuator DC - 10GHz 20dB 5 Watt N | in stock | |||
| Narda | 777C-20 | Fixed Coaxial Attenuator DC - 12.4GHz 20dB N Conn | in stock | |||
| Narda | 779-20 | Fixed Coaxial Attenuator DC-18GHz 20dB 5 Watt N | ||||
| Narda | 792FM | Variable Attenuator | 2 to 12.4GHz; 0 to 20dB. | in stock | ||
| Narda | 8616 | Radiation Survey Meter With Probes | Battery operated, direct reading in mW/cm(2) or percent of standard with 30dB dynamic range. Supplied with 8621 300MHz-40GHz and 8631 10-300MHz probes which have a measurement range of .01 to 20mW/cm(2). | |||
| Narda | 8716 8721 | Electromagnetic Radiation Monitor with Isotropic P | Ultrabroadband, portable meter performs measurements in accordance with both ANSI and FCC recommendations for radiation monitoring test equipment. Dynamic Range: 30dB with 3, 30 and 300% (ANSI Std), .1, 10 and 100mW/cm? full scale levels.
Electric Field Probe - Model 8721 Frequency Range: 300 MHz to 40 GHz Measurement Range: 10µW/cm˛ to 20mW/cm˛ Shape: Flat CW Overload (mW/cm˛): 600 Peak Overload (W/cm˛): 200 Includes: 8716 unit, 8721 probe, manual, strap, and case. |
in stock | ||
| Narda | 8716 8723 | Electromagnetic Radiation Monitor with Isotropic P | Ultrabroadband, portable meter performs measurements in accordance with both ANSI and FCC recommendations for radiation monitoring test equipment. With the 8723 probe the Frequency Range is 300KHz to to 40GHz. Dynamic Range: 30dB with 3, 30 and 300% (ANSI Std), .1, 10 and 100mW/cm˛ full scale levels. | |||
| Narda | 8718B | Radiation Monitor with 8741D Isotropic Probe 300MH | The Narda Model 8718B can satisfy the needs of almost anyone that needs to measure electromagnetic fields. The Narda 8718B was designed with the new or occasional user in mind so that the most common mistakes cannot happen. No range changes-the meter automatically displays a numeric value over the probe's entire measurement range. No confusing scales-simply select the correct probe (the meter even makes you double check) and the meter will display the correct reading. No difficult zeroing procedure-just touch one key. Even the occasional user will be able to make use of the Narda 8718B's advanced features. Experienced surveyors can do everything with a single instrument- accurately and in considerably less time than with any other instrument. The key is to access the menu system which is always available via one of the four function keys. Once you get to the correct screen, most options will be clear . And context sensitive help is always available.
Features: Microprocessor-Based Design 4 Line x 20 Character Display One-Touch Zero Displays Fields in Any Unit: mW/cm˛, W/m˛ , V/m, A/m, V˛/m˛ , A˛/m˛, pJ/cmł and Percent of International Standards Intuitive Operation with Help Screens Sophisticated Data-Logging Time and Spatial Averaging with Data Storage Fiber Optic and Cable Inputs RS232 Interface Calculates Percent of Standard Small, Lightweight, Ergonomic Design Supplied with 8741D Isotropic Electric Field Probe Frequency Range: 300 MHz to 50 GHz Measurement Range: 50µW/cm˛ to 100mW/cm˛, 13.7 to 614 V/m |
|||
| Narda | AS-18 | Precision Attenuator Set | Contains 6 model 44 fixed attenuators, 1,3,6,10,20,30 dB. DC-18GHz, 5 watt, N connectors. | |||
| National | VXI-MXI | VXI Card | in stock | |||
| Newport Labs | 3150 | Advanced High-Power Temperature Controller | The Model 3150 Temperature Controller provides a 350 W bipolar output for operation with thermoelectric (TE) coolers. Active power management of the output DC power supply reduces unnecessary power dissipation resulting in increased temperature stability and higher reliability. Full 16-bit control and characterization of the TE module and temperature sensor is attainable via the IEEE-488 or RS-232 interfaces. LabVIEW drivers are included with the computer interfaces as a standard feature.
All pertinent TE cooler parameters ITE, VTE, temperature sensor (°C, R, Amp, or Volts) are measured and simultaneously presented on the four line alphanumeric LCD display. All standard temperature sensors including thermistors, platinum RTD, AD590/592 and LM335 IC sensors are supported without the need for additional interface units. Sensor calibration constants are easily programmed for direct readout in °C. A proportional-integral (P-I) control circuit is implemented in the Model 3150 that meets all the temperature stabilization requirements for laser diode users. During operation, the front panel controls can be disabled to prevent any changes in the output by accidental misadjustment of the control knob. Protection features include: ITE Limit, Hi and Lo Temperature Limits, Sensor Open and TE Open Detection. To prevent noise pickup, either by the output lines or the sensor inputs - resulting in undesirable temperature oscillations - shielded cables are also available. Key Features 15 A/23 V, low noise, bipolar output Extremely stable, long term drift <0.001°C Multiple sensors supported: thermistors, RTD, AD590/592, and LM335 Complete characterization of TE cooler (ITE and VTE) versus temperature Automatic power management and failsafe shutdown |
http://www.kandelelex.com/jpegs/new3150.jpg | in stock | |
| Newport Labs | 5005 | Laser Diode Driver (500 mA) | The 5000 Series Laser Diode Drivers are advanced current sources based on the technology found in the 6000 and 8000 Series products. Full 16-bit control and characterization of your laser diodes is attainable via the IEEE-488 or RS-232C interfaces. LabVIEW drivers are included with the computer interfaces as a standard feature on all 5000 Series units.
All pertinent laser diode parameters Io, Im or Po, and Vf are simultaneously presented on the two line alphanumeric LCD display. Power in Watts is displayed when the responsivity of the monitor photodiode is programmed into the unit. Incorrect settings are prevented during the setup mode to protect the laser diode. When power is turned off all program settings are saved. In addition, several different setups can be saved and recalled to facilitate multiple control and test requirements. During operation the front panel inputs can be disabled by pushing the Lockout dial button located below the control knob. This prevents any inadvertent changes in the output by accidental movement of the control knob. An internal function generator is included that is programmable from 200 Hz-300 kHz in either a sinewave or squarewave output. This provides a convenient means to generate datacom and telecom test tones for system evaluation. External analog modulation is also included allowing you to modulate the output current using other waveforms and frequencies. Modulation is available in both the constant current (ACC) and constant power (APC) modes. Complete laser diode protection is provided including transient detection and filtering, intermittent contact protection, independent current limit and power limit settings, multiple output shorting circuits, and a slow turn on sequence. In addition, our shielded cables protect against radiated energy from outside equipment resulting in the lowest noise output to the laser diode. |
|||
| Newport Labs | 8000 | Modular Controller | Four fully isolated bays accept a wide variety of modules. Many new laser diode applications, requiring multiple current sources and temperature controllers, are accommodated: Multiple beam, individually addressed laser diodes; Multiple laser diode pumped fiber amplifiers; 2-D vertical cavity surface emitting laser diode arrays. Model 8350 - 40 Watt Temperature Controller Module, Model 8505 Laser Diode Driver Modules are available. | |||
| Newport Labs | ESA-C | Micro-Drive Controller |
Velocity-controlled or "immediate" execution. LabVIEW instrument driver sets are available online. |
in stock | ||
| Nikon | OPTIPHOT | Microscope / X-Y Table | This system includes a Cole-Parmer 9741-50 Low-Noise illuminator and a counter-weighted, micrometer controlled X-Y table. This unit appears to be incomplete and will be sold accordingly. There is no lens turret or fiber-optic lens. | in stock | ||
| North Atlantic | 213C | Phase Meter | Voltmeter range: 300uV to 300V; Frequency: 10Hz to 100KHz; Phase sensitive null meter with 2uV nulling sensitivity provides high resolution ratio-metric measurements. Phase accuracy: ±1°. | in stock | ||
| North Atlantic | 213C | Phase Meter | Voltmeter range: 300uV to 300V; Frequency: 10Hz to 100KHz; Phase sensitive null meter with 2uV nulling sensitivity provides high resolution ratio-metric measurements. Phase accuracy: ±1°. | http://www.kandelelex.com/jpegs/n-a213c.jpg | in stock | |
| North Atlantic | 214C | Phase Angle Voltmeter 400Hz / 4.5KHz | The quick and easy way to measure and directly read voltages.the 214C Phase Angle Voltmeter! The unit is solid-state and provides direct reading of total voltage, fundamental voltage, in-phase voltage, quadrature voltage and phase angle. The 214C is supplied with both signal and reference isolation. Frequency range covered is from 10Hz to 100kHz, phase sensitive: 1, 2, 3, or 4 frequencies from 30Hz to 20kHz with plug-in field changeable modules. Phase sensitive bandwidth of ±5%. Voltage range is 300 µV to 300 V in 13 ranges with an accuracy of ±2% full scale, phase dial is ±1°. With field changeable modules, complete recalibration is readily accomplished by a single rear-panel adjustment. | in stock | ||
| North Atlantic | 2250 | Phase Angle Voltmeter | The Model 2250 - the most versatile AC measurement tool yet developed. The instrument employs a microprocessor-based design, utilizing Fast-Fourier Transform techniques that combine many of the capabilities of today's network/waveform analyzers in a digital voltmeter configuration. Designed for the Synchro/Resolver and LVDT/RVDT marketplace, this Phase Angle Voltmeter accurately makes measurements of Phase Angle, In-Phase, Quadrature, Fundamental and Total, as well as impedance, power and harmonics. Isolated inputs allow null, ratio and gain measurements of key parameters and a reference phase offset facilitates bridging measurements. A sensitive null meter is included for precise nulling. The instrument is unusually "user friendly".
Unlike menu driven Instruments, simply by pressing individual switches on the front panel, you can access a wide number of functions. Functions accessed by a single touch include: Total, Fundamental, In-phase and Quadrature voltage and Phase Angle measurements Reference phase offset from the Signal by up to 360ş Highly accurate Ratio measurements in both phase-sensitive and voltage modes Measurement of Total Harmonic Distortion and magnitude and phase of a selected harmonic Computation of the percent deviation of a signal from a selected Nominal value Display of magnitude in db relative to either the Reference input or a selected value Reference Frequency & Amplitude Measurement Individual Voltage Ranges & Full Autorange Local & Remote IEEE, GPIB Programming Features ± 0.05 % Phase Angle and ratio accuracy 10 Hz to 100 kHz frequency response Full Feature Display includes Primary, Lock Frequency, Harmonic Order and Null Meter IEEE Interface Standard Voltage Resolution 4 1/2 Digits Phase Angle Resolution 0.01° Frequency Display Resolution 3 digits Self Calibrating Possible replacement for obsolete models 213, 213c and 321 |
in stock | ||
| North Atlantic | 2250 | Phase Angle Voltmeter | The Model 2250 - the most versatile AC measurement tool yet developed. The instrument employs a microprocessor-based design, utilizing Fast-Fourier Transform techniques that combine many of the capabilities of today's network/waveform analyzers in a digital voltmeter configuration. Designed for the Synchro/Resolver and LVDT/RVDT marketplace, this Phase Angle Voltmeter accurately makes measurements of Phase Angle, In-Phase, Quadrature, Fundamental and Total, as well as impedance, power and harmonics. Isolated inputs allow null, ratio and gain measurements of key parameters and a reference phase offset facilitates bridging measurements. A sensitive null meter is included for precise nulling. The instrument is unusually "user friendly".
Unlike menu driven Instruments, simply by pressing individual switches on the front panel, you can access a wide number of functions. Functions accessed by a single touch include: Total, Fundamental, In-phase and Quadrature voltage and Phase Angle measurements Reference phase offset from the Signal by up to 360ş Highly accurate Ratio measurements in both phase-sensitive and voltage modes Measurement of Total Harmonic Distortion and magnitude and phase of a selected harmonic Computation of the percent deviation of a signal from a selected Nominal value Display of magnitude in db relative to either the Reference input or a selected value Reference Frequency & Amplitude Measurement Individual Voltage Ranges & Full Autorange Local & Remote IEEE, GPIB Programming Features ± 0.05 % Phase Angle and ratio accuracy 10 Hz to 100 kHz frequency response Full Feature Display includes Primary, Lock Frequency, Harmonic Order and Null Meter IEEE Interface Standard Voltage Resolution 4 1/2 Digits Phase Angle Resolution 0.01° Frequency Display Resolution 3 digits Self Calibrating Possible replacement for obsolete models 213, 213c and 321 |
http://www.kandelelex.com/jpegs/n-a2250.jpg | in stock | |
| North Atlantic | 2251 | Digital Analyzing Phase Angle Voltmeter | The Model 2251 is the latest Phase Angle Voltmeter product of North Atlantic Industries, who in 1955, created the first Phase Angle Voltmeter.
Also known as the Digital Analyzing Voltmeter, it is modeled after the popular Model 2250. It incorporates its most used functions at a lower price while sacrificing some frequency bandwidth and accuracy. The instrument employs a microprocessor-based design, utilizing Fast-Fourier Transform techniques that combine many of the capabilities of today’s network/waveform analyzers in a digital voltmeter configuration. Designed for the Synchro/Resolver and LVDT/RVDT marketplace, this Phase Angle Voltmeter accurately makes measurements of Phase Angle, In-Phase, Quadrature, Fundamental and Total, as well as impedance, power and harmonics. Isolated inputs allow null, ratio and gain measurements of key parameters and a reference phase offset facilitates bridging measurements. A sensitive null meter is included for precise nulling. The instrument is unusually “user friendly”. Unlike menu driven Instruments, simply by pressing individual switches on the front panel, you can access a wide number of functions. Functions accessed by a single touch include: Total, Fundamental, In-phase and Quadrature voltage and Phase Angle measurements Reference phase offset from the Signal by up to 360ş Highly accurate Ratio measurements in both phase-sensitive and voltage modes Individual Voltage Ranges & Full Autorange Local & Remote IEEE, GPIB Programming The instrument Calibrates itself. At turn-on or frequency change, the instrument automatically initiates a self-calibration sequence. This checks critical performance criteria and makes internal adjustments that maximize accuracy. This sequence can be initiated by the user at any time. Long term accuracy and stability is thus assured. ± 0.05 % Phase Angle and ratio accuracy 30 Hz to 54 kHz frequency response Full Feature Display IEEE Interface Standard Voltage Resolution 4 1/2 Digits Phase Angle Resolution 0.01° Frequency Display Resolution 3 digits Self Calibrating Multi-Function, High Accuracy, Digital Analyzing Phase Angle Voltmeter(PAV) Replacement for obsolete models 212, 213, 214 & 321 Rack Mountable & Bench Top 6 Inch Bi-Polar Nullmeter |
|||
| North Atlantic | 530 | Syncro Resolver / Simulator | Features:
0.0001° Resolution Accuracy to 2 arc second Full 0-360° rotation with direct angular readout One knob controls the tens and hundreds digits Isolated inputs and outputs Transformation ratio variation from nominal ±0.2% as a function of angle Negligible phase shift Input lines fuse protected Single set of output terminals for synchro and resolver simplifies system hookup Front and rear connection terminals Switch selectable line to line levels |
|||
| North Atlantic | 530 | Syncro Resolver / Simulator | Features:
0.0001° Resolution Accuracy to 2 arc second Full 0-360° rotation with direct angular readout One knob controls the tens and hundreds digits Isolated inputs and outputs Transformation ratio variation from nominal ±0.2% as a function of angle Negligible phase shift Input lines fuse protected Single set of output terminals for synchro and resolver simplifies system hookup Front and rear connection terminals Switch selectable line to line levels |
http://www.kandelelex.com/jpegs/n-a530.jpg | ||
| North Atlantic | 530-20 | Wideband Synchro / Resolver Standard 50Hz - 11KHz | MODEL 530/20
The MODEL 530/20 Wideband Synchro/Resolver Standard incorporates many of the features of the MODEL 530, with performance over the frequency range of 50 Hz to 11 Khz. Accuracy is 10 arc seconds at 60 and 400 hz, while it is 20 arc seconds at 10 Khz. Mode and line to line voltage selection is available when selecting the 400 hz operation. However 60 hz is defined as Synchro only, 90 vrms line to line output; while 10 khz is Resolver only at switch selectable line to lines. Mode Switch 60 hz Position: Accuracy: 10 arc sec(50hz-120hz0: 20 arc sec(120hz-200hz) Input: 115 vrms F rating: 2.OF or 170 vrms max Mode: Synchro Output L-L: 90 vrms Mode Switch 400 hz Position: Accuracy: 20 arc sec(120hz-200hz); 10 arc sec(200hz-800hz); 30 arc sec(800hz-2Khz) Input: 26 or 11.5 vrms F rating: 26v - 0.5F or 40 vrms; 11.5v - 2.OF Or 170 vmns Modes: Synchro or Resolver (Switch Selectable) Output L-L: 11.8, 26, 90, 115 vrms Mode Switch 10 Khz Position: Accuracy: 30 arc sec(1Khz-9Khz); 20 arc sec(9Khz-11Khz) Input:26 or 115 vrms F rating: 26v - 0.012F or 40 vrms max; 115v - 0.05F or 170 vrms max Mode: Resolver Output L-L: 11.8, 26, 90, 11 5 vrms Resolution: 0.001 degrees Size: 5.25 x 19 x 15in (13 2 x 475 x 375mm) Weight: 72 Ibs (33 Kgs) |
in stock | ||
| North Atlantic | 5310 | Programmable Synchro/Resolver Simulator | The North Atlantic Industries 5310 Programmable Resolver/Synchro Simulator can be used as a bench-top unit or as a completely programmable device for ATE systems. Designed to drive control-type synchros and resolvers, typical applications include production testing, simulation systems and general purpose automatic synchro/resolver testing. Featuring 18 bit resolution, 3.0 VA output and 36 arc-second accuracy the 5310 is ideally suited for many commercial and military applications.
Features: Variable ProgrammableTracking Rate 3.0 VA Output 18-bit/0.01° Resolution 36 arc-second Accuracy Wideband: 47-440 Hz or 360 Hz-5 kHz Manual/Remote Operation Optional IEEE-488 Switchable BCD or Binary Programming |
http://www.kandelelex.com/jpegs/n-a5310.jpg | in stock | |
| North Atlantic | 5310 F-2-1 | Programmable Syncro / Resolver Simulator 360 - 500 | The North Atlantic Industries 5310 Programmable Resolver/Synchro Simulator can be used as a bench-top unit or as a completely programmable device for ATE systems. Designed to drive control-type synchros and resolvers, typical applications include production testing, simulation systems and general purpose automatic synchro/resolver testing. Featuring 18 bit resolution, 3.0 VA output and 36 arc-second accuracy the 5310 is ideally suited for many commercial and military applications.
Installed Options: F1-2: IEEE Interface F2-1 Frequency Range 360 - 5000 Hz Features: Variable ProgrammableTracking Rate 3.0 VA Output 18-bit/0.01° Resolution 36 arc-second Accuracy Manual/Remote Operation Optional IEEE-488 installed Switchable BCD or Binary Programming |
in stock | ||
| North Atlantic | 540 | Syncro / Resolver Bridge | Provides direct measurement of resolver and synchro simulators. Features a constant null gradient output voltage, isolated input and output and <500k ohm input impedance. Accuracy: 2 arc seconds at 400Hz, usable to 10KHz. Input: .8f (f in Hz) to 300 volts. | in stock | ||
| North Atlantic | 540-10 | Syncro / Resolver Bridge | Provides direct measurement of resolver and synchro simulators. Features a constant null gradient output voltage, isolated input and output and <500k ohm input impedance. Accuracy: 2 arc seconds at 400Hz, usable to 10KHz. Input: .8f (f in Hz) to 300 volts. | in stock | ||
| North Atlantic | 540-10 | Syncro / Resolver Bridge | Provides direct measurement of resolver and synchro simulators. Features a constant null gradient output voltage, isolated input and output and <500k ohm input impedance. Accuracy: 2 arc seconds at 400Hz, usable to 10KHz. Input: .8f (f in Hz) to 300 volts. | http://www.kandelelex.com/jpegs/n-a540-10.jpg | in stock | |
| North Atlantic | 540-20 | Syncro / Resolver Bridge | Provides direct measurement of resolver and synchro simulators. Features a constant null gradient output voltage, isolated input and output and <500k ohm input impedance. Accuracy: 2 arc seconds at 400Hz, usable to 10KHz. Input: .8f (f in Hz) to 300 volts. | in stock | ||
| North Atlantic | 540-20 | Syncro / Resolver Bridge | Provides direct measurement of resolver and synchro simulators. Features a constant null gradient output voltage, isolated input and output and <500k ohm input impedance. Accuracy: 2 arc seconds at 400Hz, usable to 10KHz. Input: .8f (f in Hz) to 300 volts. | http://www.kandelelex.com/jpegs/n-a540-20.jpg | in stock | |
| North Atlantic | 8300 | Programmable Angle Position Indicator | Range: 0 to 359.99° with 0.01° resolution and ±0.05° accuracy. Frequency: 47 to 440Hz. Signal input (synchro or resolver): 11.8, 26, or 90V L-L. 2 channels. | in stock | ||
| North Atlantic | 8300 | Programmable Angle Position Indicator | Range: 0 to 359.99° with 0.01° resolution and ±0.05° accuracy. Frequency: 47 to 440Hz. Signal input (synchro or resolver): 11.8, 26, or 90V L-L. 2 channels. | http://www.kandelelex.com/jpegs/n-a8300.jpg | in stock | |
| North Atlantic | 8300 02-07 | Angle Position Indicator | Range: 0 to 359.99° with 0.01° resolution and ±0.05° accuracy. Frequency: 47 to 440Hz. Signal input (synchro or resolver): 11.8, 26, or 90V L-L. 2 channels.
Option 02 minutes 7; 07 .03 degree accuracy. |
|||
| North Atlantic | 8800 | Angle Position Indicator | Range: 0 to 359.999° with 0.001° resolution and ±0.004° accuracy. Frequency range: 360 to 1200Hz (47-440Hz optional). Signal input (synchro or resolver): 11.8, 26, or 90V L-L autoranging. 2 channels. | in stock | ||
| North Atlantic | 8800 | Angle Position Indicator | Range: 0 to 359.999° with 0.001° resolution and ±0.004° accuracy. Frequency range: 360 to 1200Hz (47-440Hz optional). Signal input (synchro or resolver): 11.8, 26, or 90V L-L autoranging. 2 channels. | http://www.kandelelex.com/jpegs/n-a8800.jpg | in stock | |
| North Atlantic | 8800 06 | Angle Position Indicator 200-1200Hz .001 deg resol | Range: 0 to 359.999° with 0.001° resolution and ±0.004° accuracy. Frequency range:200 to 1200Hz . Signal input (synchro or resolver): 11.8, 26, or 90V L-L autoranging. 2 channels. | in stock | ||
| North Atlantic | 8810 02 | Syncro/Resolver Angle Position Indicator | Based on North Atlantic Instruments Trig-Logic processor the Model 8810 truly represents a major step forward in Synchro/Resolver to digital converter technology. With a resolution of 0.001° this full tracking type II servo converter can track without velocity error to 200°/sec. The Model 8810 has front panel controls and input terminations while retaining the rear I/O and programming of the model 8800.
Two pushbutton front-panel selectable input channels are provided. In the remote mode, the user can program the desired input channel. BCD outputs, data freeze and converter busy signals are standard features making the unit ideal for ATE applications requiring "hands-off operation". A bright, easy to read, 0.55" Plasma Display makes the unit an easy to read instrument even in bright light. Features: 0.001° Resolution 0.004° Accuracy Auto line-to-line select Standard 360-1200Hz Frequency Range Phase Sensitive Detection Autophase Correction Dimensions 12.5" L x 9.5" W x 3.5" H Display is 0 to 359.999ş Frequency range is 360 to 1200Hz. |
|||
| North Atlantic | 8810 02 | Syncro/Resolver Angle Position Indicator | Based on North Atlantic Instruments Trig-Logic processor the Model 8810 truly represents a major step forward in Synchro/Resolver to digital converter technology. With a resolution of 0.001° this full tracking type II servo converter can track without velocity error to 200°/sec. The Model 8810 has front panel controls and input terminations while retaining the rear I/O and programming of the model 8800.
Two pushbutton front-panel selectable input channels are provided. In the remote mode, the user can program the desired input channel. BCD outputs, data freeze and converter busy signals are standard features making the unit ideal for ATE applications requiring "hands-off operation". A bright, easy to read, 0.55" Plasma Display makes the unit an easy to read instrument even in bright light. Features: 0.001° Resolution 0.004° Accuracy Auto line-to-line select Standard 360-1200Hz Frequency Range Phase Sensitive Detection Autophase Correction Dimensions 12.5" L x 9.5" W x 3.5" H Display is 0 to 359.999ş Frequency range is 360 to 1200Hz. |
http://www.kandelelex.com/jpegs/n-a8810.jpg | ||
| North Atlantic | 8810 F12 | Angle Position Indicator 0-400 deg 360-1200Hz GPIB | Based on North Atlantic Instruments Trig-Logic processor the Model 8810 truly represents a major step forward in Synchro/Resolver to digital converter technology. With a resolution of 0.001° this full tracking type II servo converter can track without velocity error to 200°/sec. The Model 8810 has front panel controls and input terminations while retaining the rear I/O and programming of the model 8800.
Two pushbutton front-panel selectable input channels are provided. In the remote mode, the user can program the desired input channel. BCD outputs, data freeze and converter busy signals are standard features making the unit ideal for ATE applications requiring "hands-off operation". A bright, easy to read, 0.55" Plasma Display makes the unit an easy to read instrument even in bright light. Features: 0.001° Resolution 0.004° Accuracy Auto line-to-line select Standard 360-1200Hz Frequency Range Phase Sensitive Detection Autophase Correction Dimensions 12.5" L x 9.5" W x 3.5" H Display is 0 to 359.999ş Frequency range is 360 to 1200Hz. GPIB |
in stock | ||
| North Atlantic | 8810 F21 | Angle Position Indicator 47-440Hz | Based on North Atlantic Instruments Trig-Logic processor the Model 8810 truly represents a major step forward in Synchro/Resolver to digital converter technology. With a resolution of 0.001? this full tracking type II servo converter can track without velocity error to 200?/sec. The Model 8810 has front panel controls and input terminations while retaining the rear I/O and programming of the model 8800.
Two pushbutton front-panel selectable input channels are provided. In the remote mode, the user can program the desired input channel. BCD outputs, data freeze and converter busy signals are standard features making the unit ideal for ATE applications requiring "hands-off operation". A bright, easy to read, 0.55" Plasma Display makes the unit an easy to read instrument even in bright light. Features: 0.001 deg Resolution 0.004 deg Accuracy Auto line-to-line select 47Hz - 440Hz Frequency Range Phase Sensitive Detection Autophase Correction Dimensions 12.5" L x 9.5" W x 3.5" H Display is 0 to 359.999 deg Frequency range is 47 to 440Hz. |
|||
| Northeast Electronics Corp | 805-P5564B | Optical Attenuator | Mechanical unit has a 50dB step range(10dB/step) and a 10dB vernier dial. "ST" connectors. | |||
| Nurad, Inc | 1701-3 | LS-Band Standard Gain Horn | in stock | |||
| Omega | 600-06 | Temperature Recorder | Up to 6 channels; 12 chart speeds:1 to 30cm/hr or 1 to 60cm/min; Recording width: 250mm; Complete with five type J temperature modules and one millivolt module. | http://www.kandelelex.com/jpegs/ome600-06.jpg | ||
| Omega | 640-2-J-V | 2-Channel Flatbed Recorder | Channel 1 measures temperature from -50°C to 600°C with Type J thermocouple. Channel 2 records millivolts from 1mV to 100V f.s. Chart speeds: 1cm/hr to 60cm/min in 12 steps. 120mm chart width. | in stock | ||
| Omega | OM-271 | Temperature Recorder / Data Logger | Provides 32 channels of temperature measurement and 2 alarm relays with screw terminal connections. Pullout keypad selects channels and timing. | |||
| Omega | OMNI-CAL IIB | Portable Thermocouple / Loop Calibrator | Measurement and simulation of 7 thermocouples. Measurement of 0-100mA with resolution to 0.001mA and 0-60V with resolution to 0.001V. Output of 0-55mA and 0-11V. Same as Biddle 720360 Versa-Cal. | in stock | ||
| Omni Spectra | 2001-6005-00 | Coaxial Termination DC - 18GHz 20 Watt SMA (m) | in stock | |||
| Omni Spectra | 20187AJ | Waveguide To Coaxial (sma) Adapter | in stock | |||
| Omni Spectra | 20600-10 | SMA Attenuator DC - 18GHz 10dB | in stock | |||
| Omni Spectra | 2082-6502-20 | Coaxial Attenuator DC - 18GHz 20dB 10 Watt SMA (m | 20dB ±.75; DC to 18GHz; 10 watts;(500 watts peak) | in stock | ||
| Otto Wolff | .01 | Standard Resistor .01 Ohm | in stock | |||
| Otto Wolff | 0.1 | Standard Resistor .1 Ohm | ||||
| Otto Wolff | 1 | Standard Resistor 1 Ohm | in stock | |||
| Otto Wolff | 100 | Standard Resistor mAnganin .33a | in stock | |||
| Otto Wolff | 10000 | Standard Resistor 10ko | http://www.kandelelex.com/jpegs/owf10000.jpg | in stock | ||
| Otto Wolff | 100K | Standard Resistor mAnganin .002A | in stock | |||
| Otto Wolff | 10K | Standard Reisitor mAnganin .01a | in stock | |||
| Otto Wolff | 1K | Standard Resistor mAnganin .033a | in stock | |||
| Pacific Power Source | 110E | AC Power Source | Output: 1000VA, single phase, 0 to 125/250VAC, 0 to 8/4amps, 47 to 2000Hz, 0.1% regulation, 0.75% distortion (.4% typical). Input: 115/230VAC, 30/15 amp service. Supplied with 1-F, fixed 400Hz oscillator. Three of these units can easily be set up into a 3 phase system. | |||
| Pacific Power Source | 140ASX-UPC1 | Programmable AC Power Source 4000VA 1 phase RS-232 | The ASX Series is a family of High Performance Switching AC power sources covering the power range from 1.5kVA to 6kVA (12kVA to be released soon). The product line offers both single and three phase models. Units are conservatively designed and output power ratings are based on the most severe combination of input line, output voltage, power factor, and temperature.
Great emphasis has been placed on low acoustic noise, ease of installation, and maximum power per cubic inch of rack space. Control and operational features provide a high degree of application versatility and ease of use for the test engineer. Applications range from simple, manually controlled frequency conversion to harmonic testing and sophisticated bus programmable transient simulation. Power conversion within the ASX Series is achieved by high frequency pulse width modulation, resulting in cool, quiet and efficient operation. Rated Power: 4000VA Output Form: 1 phase Output Volts (rms): 135 / 270VAC Output Amps: 32 / 16 Arms Output Frequency: 15 Hz to 1,200 Hz Input Power: 208 / 230 VAC, 3 phase |
|||
| Pearson | 1010 | Current Monitor | Output: 0.1 volt/amp. Diameter: 10.75". Max Peak Current: 5,000 amps. Frequency: 400Hz to 7MHz. | |||
| Pearson | 110 | Current Monitor | Frequency: 1Hz to 20MHz with 20ns risetime. Maximum RMS Current: 65 amps. Maximum Peak Current: 5,000 amps. Output: .1 volt/amp. 2" hole diameter. | |||
| Pearson | 325 | Wideband Current/pulse Transformer | Sensitivity 0.25 Volt/Ampere +1/-0%
Output resistance 50 Ohms Maximum peak current 2,000 Amperes Maximum rms current 60 Amperes Droop rate 0.1 %/microsecond Useable rise time 30 nanoseconds Current time product 0.09 Ampere-second Low frequency 3dB cut-off 160 Hz (approximate) High frequency 3dB cut-off 10 MHz (approximate) I/f figure 0.6 peak Amperes/Hz Output connector UHF (SO-239) Shielding Double Operating temperature 0 to 65 oC Weight 15.4 pounds |
|||
| Piezo Systems Inc | EPA-102 | Linear Amplifier DC - 300KHz | The EPA-102 is a high voltage (±200 Vp), high current (± 200 mA), and high frequency (DC to 250 KHz) amplifier designe to drive higher capacitive capacitive loads, such as ultrasonic devices, at high frequencies.
The ability of an amplifier to drive a piezo device statically is determined by its voltage capability and stability. Its ability to drive a piezo device dynamically is determined by the capacitance of the actuator, the voltage to which it must be driven, and the number of times it must be charged and discharged per second. These establish the current, voltage, and frequency requirements of the amplifier. Frequency range (kHz) DC to 300 Output power (W peak) 40 Max. voltage (V peak) ± 200 Max. current (mA peak) ± 200 Voltage gain 20 Slew rate (V/μs) 30 Maximum input voltage (V) ±10 |
|||
| Planer Products Limited | GB7 | Gas Bonder | Hot gas micro-soldering system. Time or continuous gas flow, set time: 1-30 sec. Adjustable flow rate. | in stock | ||
| Planer Products Limited | HG3 | Gas Bonder | Hot gas micro-soldering system. Time or continuous gas flow, set time: 1-30 sec. Adjustable flow rate. | in stock | ||
| Polorad | CA-L | Horn Antenna | Frequency range: 1 to 2.34 GHz. | |||
| Polorad | CA-S | Horn Antenna | Frequency range: 2.14 to 4.34 GHz. | |||
| Power Design | 1120S | Power Supply 0 - 120V 0 - 1A | in stock | |||
| Power Design | 3650S | Power Supply 0-36V 0-5A | ||||
| Power Design | 4005 | Power Supply 0 - 40V 0 - .5A | in stock | |||
| Power Design | 6050 | Power Supply 0 - 7 / 60V 0 - 5 / .5A | in stock | |||
| Power Design | 6050A | Power Supply 0 - 7 / 60V 0 - 5 / 1A | in stock | |||
| Power Design | 6050C | Power Supply 0-6/15/30/60v 0-5/3/2/1a | ||||
| Power Design | 6050D | Power Supply 0 - 60 / 30 /15 / 6V 0 - 1 / 2/ 3 / | Patented Uniplyr circuit technology
Constant voltage/constant current Adjustable overvoltage crowbar Liquid crystal digital display Autoranging 0-60 VDC continuously adjustable output Linear regulator system is RFI free Useful regulated output with 85 VAC line Up to 150% of output rating with input line voltages above 105 VAC |
in stock | ||
| Power Design | TP343A | Triple Supply 0 - ±20 / 25V 0 - 2.5 / 1A 0 - 6 / | .01% regulation; >1mVp-p ripple; auto-tracking and OVP. | in stock | ||
| Power Design | TW5005 | Dual Power Supply 0 - 50V 0 - .5A | in stock | |||
| Power Design | TW5005W | Dual Power Supply 0 - 50V 0 - .5A | in stock | |||
| Power Ten | 3300D-2030 | Power Supply 0-20v 0-30a Switcher | ||||
| Power Ten | 3304D-2030 | Power Supply 0-20v 0-30a Switcher | ||||
| Power Ten | 3304D-2050 | Power Supply 0-20v 0-50a Switcher | ||||
| Power Ten | 3350C-1060 | Power Supply 0 - 10V 0 - 60A Switcher | in stock | |||
| Power Ten | 3350C-2030 | Power Supply 0 - 20V 0 - 30A Switcher | in stock | |||
| Power Ten | 3400D-7.5250 | Power Supply 0 - 7.5V 0 - 250A Switcher | in stock | |||
| Power Ten | 4600D-20250 | Power Supply 0-20v 0-250a Switcher | ||||
| Power Ten | 4604D-20215 | Power Supply 0 - 20V 0 - 125A 208VAC 3-Phase | in stock | |||
| Power Ten | 4700D-45022 | Power Supply 0-450v 0-22A 208VAC 3ph Switcher | ||||
| Power Ten | 4700P-25040 | Power Supply 0-250v 0-40a 208 3ph | ||||
| Power Ten | 6101-4050 | Power Supply 0 - 40V 0 - 50A 230VAC Switcher | in stock | |||
| Power Ten | I66C-60330 | Programmable DC Power Supply 0-60V 0-330A GPIB Swi | This series of programmable DC switching power supplies offers:
Low P_P Ripple and Noise 100mVp-p Preset and Monitor of OVP Limit Set IEEE 488.2 Remote programming Regulation (line or load) 0.1% 190-253VAC 3ph input |
|||
| PRD | 1209-F1 | WG Isolator 18-26GHz 24dB Isolation 10 Watt Ug599u | ||||
| PRD | 155-F1 | WG K-Band Attenuator Variable 0 - 40dB | in stock | |||
| PRD | 413 | WG Directional Coupler 12 - 18GHz 10dB | in stock | |||
| PRD | CX518 | BroadBand Coaxial Frequency Meter | Frequency range: 3.7 TO 12.4GHz direct reading. Accuracy: ±0.17%. Type N connectors. 1 dB resonance dip. Similar to HP 537A. | in stock | ||
| Princeton Applied Research (eg&g) | 124 | Lock-in Amplifier | Accurately measures the amplitude and phase of weak signals buried in noise; 2Hz to 210KHz; sensitivity: 500µV with 21 full scale ranges. I100M ohm SE/DE; 120dB at 60Hz; 1µV sensitivity; 200VDC max input for 185 preamp. Preamps are available. | |||
| Princeton Applied Research (eg&g) | 124A | Lock-in Amplifier | Accurately measures the amplitude and phase of weak signals buried in noise; 2Hz to 210KHz; sensitivity: 500µV with 21 full scale ranges. Includes 116 or 117 differential preamp: 100M ohm SE/DE; 120dB at 60Hz; 1µV sensitivity; 200VDC max input or 185 preamp. Other preamps are available. | http://www.kandelelex.com/jpegs/par124a.jpg | in stock | |
| Quadtech | 1433-10 | Decade Resistor Box 1111.1 Ohm 5-Dial .01 ohm/ste | The 1433 Decade Resistors are primarily intended for precision measurment applications where their excellent accuracy, stability, and low zero resistance are impotant.
The 1433-10 is equal to the General Radio 1433T. This unit has 5-dials with .01 ohm/step and 1111.1 total resistance. The basic accuracy is .01%. |
in stock | ||
| Quadtech | 1433-16 | Decade Resistor Box 1.1111M Ohm 10 Ohm/step 5-Dial | in stock | |||
| Quadtech | 1692 | Digibridge RLC Tester 100Hz - 100KHz .05% Accuracy | The 1692 is a sophisticated, microprocessor-controlled tester that brings new levels of flexibility, simplicity and accuracy to RLC measurement. It's testing automation at its best with a range of programmable test frequencies and test voltages, as well as automatic limit comparison, automatic parameter selection, remote programmability, automatic binning and automatic zeroing.
FEATURES: 0.05% Accuracy for RLC measurements; 0.0003 for D and Q measurements. Five selectable test frequencies: 100Hz, 120Hz, lkHz, 10kHz and 100kHz for greater versatility in component testing. Choice of two commonly specified AC test voltages. Three keyboard-selectable test speeds; 2,4 or 8 measurements per second complements automatic handling equipment to maximize throughput. A choice of two measurement modes; Triggered and Continuous with averaging available in each ensures measurement flexibility. Wide choice of measurement parameters allow you to work with familiar units. A full, five-digit LED display for RLC measurements and a four-digit readout for D and Q testing, simultaneously display both test results for each measurement, automatically Guarded Kelvin measurement techniques protect measurement integrity. Automatic limit comparison and binning ensure fast, mistake-proof sorting of components. Optional IEEE-488 Bus and Handler Interface enable remote programming and allow the addition of a component handler to optimize throughput. |
http://www.kandelelex.com/jpegs/qt1692.jpg | in stock | |
| Quadtech | 1693 | Precision RLC Digibridge |
0.02% Accuracy for LCR, G Z and Y 0.0001 Accuracy for DQ measurements Programmable test frequencies from 12Hz to 200kHz Programmable test voltages from 5mV to 1.275V permits testing at exact manufacturer-specified voltage levels Full range keyboard-selectable test speeds: Variable up to 50 measurements per second with high speed option, complements automatic handling equipment to maximize throughput Two selectable measurment modes: Continuous and triggered with averaging available in each ensures measurement flexibility Optional IEEE-488 Bus and Handler interface enable remote programming and allow the adition of a component handler to optimize throughput Wide choice of measurement parameters allow you to work with familiar units A full, five-digit LED display for LCR measurements and a four-digit readout for D and Q testing, simultaneously display test results for each measurement, automatically Guarded Kelvin measurement techniques protect measurement integrity Automatic limit comparison and binning ensure fast, mistake-proof sorting of components. Automatic self-test and diagnostic check maintain reliable, error-free operation Automatic binning summary capability simplifies reporting of measurement results |
http://www.kandelelex.com/jpegs/qt1693.jpg | ||
| Quadtech | 1710 | Digibridge LCR Meter | The Quadtech 1710 is a LCR Digibridge. The 1710 Digibridge makes primary measurements of L, C, and R and secondary measurements of D and Q. L, C & R measurements are made at a frequency of 120Hz or 1kHz with a basic accuracy of ±0.2%. The accuracy of the secondary parameters for D or Q <1, is ± 0.001 for Q (with R), ±0.01 for Q (with L), and ± 0.0005 for D (with C). | |||
| Quadtech | 1730 | Precision LCR Meter 50Hz - 100KHz | The QuadTech 1730 can measure and display two of 14 impedance parameters simultaneously with a basic accuracy of 0.1%. Test results can also be shown as Deviation or %Deviation from nominal value. 10 Test Frequencies: User selectable: 50Hz, 60Hz, 100Hz, 120Hz, 1kHz, 10kHz, 20kHz, 40kHz, 50kHz and 100kHz. LCD Display: Large, high resolution graphic display for clear, concise results and user friendly menu interface for easy programming. Setup Store/Recall: Store/Recall up to 50 test setups from instrument memory. Lockout front panel to ensure procedures are run the same way every time. Programmable Source Impedance: Program tester impedance to 100 ohm, 100/25 ohm, 25 ohm or 10 ohm constant current when comparing results with measurements made on other testers. Measurement results can vary significantly based solely on the source impedance of the tester being used. Voltage/Current Monitoring: Use the test signal monitoring function to display the actual voltage level across and current through the DUT. DC Bias: External and internal DC Bias voltage from 0-5V, permits capacitors to be tested under real DC bias conditions. Open/Short Zeroing: Reduce the effects of error sources (stray admittance/residual impedance) between the DUT and the calibrated connection to the measuring instrument.Fast Testing: Select from one of three measurement speeds: slow, medium or fast for varying degrees of accuracy and speed up to 62 measurements/second. Interfaces Standard: The 1730 unit includes IEEE-488 and Handler interfaces for adaption into production environments or remote control applications.
Features Measures 14 Impedance Parameters (2 simultaneously) 0.1% Basic Measurement Accuracy 10 Test Frequencies from 50Hz to 100kHz AC Test Voltage Programmable from 10mV to 1V Fast Measurement Speeds up to 62/Second Automatic Open/Short Zeroing Eliminates Connection Errors LCD Display for Menu Programming and Test Results Hi/Lo Comparator Limits and 8 Sorting Bins for Pass Fail Testing IEEE-488 and PLC Interfaces Standard Results Displayed as Deviation or %Deviation from a Nominal Value Storage and Recall of 50 Test Setups Monitor Voltage and Current to the Device Under Test Keypad Lockout Prevents Changes to the Test Setup Programmable Average and Delay Times Capable of Applying a DC Bias Voltage or Current to the Device Automatic Correction for Different Test Lead Lengths |
http://www.kandelelex.com/jpegs/qt1730.jpg | ||
| Quadtech | 1865 | Digital Megohmmeter / IR Tester | The QuadTech 1865 is a Megohmmeter and Insulation Resistance tester combined in one unit. Features; basic measurement accuracy of 0.5%, voltage range from 1V to 1000V DC in 2 ranges with 25mV resolution and 1% accuracy, measurement range from 1k ohm to 100T ohm in 7 ranges, RS232 interface, automatic zero, pass/fail display. Option 01= IEEE interface.
Features Measurements from 1k ohm to 100T ohm, with Auto Ranging Direct Reading of Measured Resistance or Current 0.5% Basic Measurement Accuracy Programmable Test Voltage from 1 to 1000VDC Large LCD Display for Menu Programming and Test Results Fully Programmable Measure Cycle Times Averaging for Increased Accuracy Storage of Multiple Test Setups for Quick Startup RS-232 and PLC Interfaces Standard, IEEE-488 Optional Keypad Lockout with Password Protection Automatic Test Lead Zeroing To Eliminate Connection Errors Limit Entry for Pass/Fail Testing Safety Interlock and High Voltage Indicator for Operator Safety |
in stock | ||
| Quadtech | 1865 | Digital Megohmmeter / IR Tester | The QuadTech 1865 is a Megohmmeter and Insulation Resistance tester combined in one unit. Features; basic measurement accuracy of 0.5%, voltage range from 1V to 1000V DC in 2 ranges with 25mV resolution and 1% accuracy, measurement range from 1k ohm to 100T ohm in 7 ranges, RS232 interface, automatic zero, pass/fail display. Option 01= IEEE interface.
Features Measurements from 1k ohm to 100T ohm, with Auto Ranging Direct Reading of Measured Resistance or Current 0.5% Basic Measurement Accuracy Programmable Test Voltage from 1 to 1000VDC Large LCD Display for Menu Programming and Test Results Fully Programmable Measure Cycle Times Averaging for Increased Accuracy Storage of Multiple Test Setups for Quick Startup RS-232 and PLC Interfaces Standard, IEEE-488 Optional Keypad Lockout with Password Protection Automatic Test Lead Zeroing To Eliminate Connection Errors Limit Entry for Pass/Fail Testing Safety Interlock and High Voltage Indicator for Operator Safety |
http://www.kandelelex.com/jpegs/qt1865.jpg | in stock | |
| Quadtech | 1865 | Digital Megohmmeter / IR Tester | The QuadTech 1865 is a Megohmmeter and Insulation Resistance tester combined in one unit. Features; basic measurement accuracy of 0.5%, voltage range from 1V to 1000V DC in 2 ranges with 25mV resolution and 1% accuracy, measurement range from 1k ohm to 100T ohm in 7 ranges, RS232 interface, automatic zero, pass/fail display. Option 01= IEEE interface.
Features Measurements from 1k ohm to 100T ohm, with Auto Ranging Direct Reading of Measured Resistance or Current 0.5% Basic Measurement Accuracy Programmable Test Voltage from 1 to 1000VDC Large LCD Display for Menu Programming and Test Results Fully Programmable Measure Cycle Times Averaging for Increased Accuracy Storage of Multiple Test Setups for Quick Startup RS-232 and PLC Interfaces Standard, IEEE-488 Optional Keypad Lockout with Password Protection Automatic Test Lead Zeroing To Eliminate Connection Errors Limit Entry for Pass/Fail Testing Safety Interlock and High Voltage Indicator for Operator Safety |
http://www.kandelelex.com/jpegs/qt1865 01.jpg | in stock | |
| Quadtech | 1865 01-02 | Digital Megohmmeter / IR Tester | Megohmmeter and Insulation Resistance tester combined in one unit. Features; basic measurement accuracy of 0.5%, voltage range from 1V to 1000V DC in 2 ranges with 25mV resolution and 1% accuracy, measurement range from 1k ohm to 100T ohm in 7 ranges, RS232 interface, automatic zero, pass/fail display. Options: 01=IEEE interface, 02=3.5" Floppy Drive.
Features Measurements from 1k ohm to 100T ohm, with Auto Ranging Direct Reading of Measured Resistance or Current 0.5% Basic Measurement Accuracy Programmable Test Voltage from 1 to 1000VDC Large LCD Display for Menu Programming and Test Results Fully Programmable Measure Cycle Times Averaging for Increased Accuracy Storage of Multiple Test Setups for Quick Startup RS-232 and PLC Interfaces Standard, IEEE-488 Optional Keypad Lockout with Password Protection Automatic Test Lead Zeroing To Eliminate Connection Errors Limit Entry for Pass/Fail Testing Safety Interlock and High Voltage Indicator for Operator Safety |
|||
| Quadtech | 1865 01-02 | Digital Megohmmeter / IR Tester | Megohmmeter and Insulation Resistance tester combined in one unit. Features; basic measurement accuracy of 0.5%, voltage range from 1V to 1000V DC in 2 ranges with 25mV resolution and 1% accuracy, measurement range from 1k ohm to 100T ohm in 7 ranges, RS232 interface, automatic zero, pass/fail display. Options: 01=IEEE interface, 02=3.5" Floppy Drive.
Features Measurements from 1k ohm to 100T ohm, with Auto Ranging Direct Reading of Measured Resistance or Current 0.5% Basic Measurement Accuracy Programmable Test Voltage from 1 to 1000VDC Large LCD Display for Menu Programming and Test Results Fully Programmable Measure Cycle Times Averaging for Increased Accuracy Storage of Multiple Test Setups for Quick Startup RS-232 and PLC Interfaces Standard, IEEE-488 Optional Keypad Lockout with Password Protection Automatic Test Lead Zeroing To Eliminate Connection Errors Limit Entry for Pass/Fail Testing Safety Interlock and High Voltage Indicator for Operator Safety |
http://www.kandelelex.com/jpegs/qt1865 01-02.jpg | ||
| Quadtech | 1865 01-02-CE | Digital Megohmmeter/IR Tester | Megohmmeter and Insulation Resistance tester combined in one unit. Features; basic measurement accuracy of 0.5%, voltage range from 1V to 1000V DC in 2 ranges with 25mV resolution and 1% accuracy, measurement range from 1k ohm to 100T ohm in 7 ranges, RS232 interface, automatic zero, pass/fail display. options: 01=IEEE interface; 02=3.5" Floppy Drive; CE=CE Marked.
Features Measurements from 1k ohm to 100T ohm, with Auto Ranging Direct Reading of Measured Resistance or Current 0.5% Basic Measurement Accuracy Programmable Test Voltage from 1 to 1000VDC Large LCD Display for Menu Programming and Test Results Fully Programmable Measure Cycle Times Averaging for Increased Accuracy Storage of Multiple Test Setups for Quick Startup RS-232 and PLC Interfaces Standard, IEEE-488 Optional Keypad Lockout with Password Protection Automatic Test Lead Zeroing To Eliminate Connection Errors Limit Entry for Pass/Fail Testing Safety Interlock and High Voltage Indicator for Operator Safety |
http://www.kandelelex.com/jpegs/qt1865 01-02-ce.jpg | ||
| Quadtech | 1880 | Milliohmmeter 2 Mohms Down To 1 µohm | The Quadtech 1880 Milliohmmeter provides ease of use, digital display and excellent accuracy for performing low resistance measurements on switches, relays, connectors and a variety of other devices. The instrument offers a wide measurement range, from 1 µohm to 2 Mohms, with constant current ranging from 1 A to 1 µA. A built-in comparator makes the unit ideal for go/nogo testing in a production environment and is also adaptable for use in automated system applications with it's optional IEEE-488 interface.
Precision Measurements The 0.05% accuracy of the 1880 makes for consistent, reliable test results from this economically priced unit. Nine measurement ranges, automatic or manually selectable, provide wide coverage between 2 Mohms and 1 µohm with constant current between 1 µA and 1A. FEATURES: Measurement Range, 1 µohm to 2Mohm 1 µA to 1 A, Constant Current 0.05% Measurement Accuracy Measurement Speed of 5/second Easy to Read Digital Display Four-Terminal Kelvin Connections Automatic Zeroing Built-in Comparator for Go/NoGo Testing Display of % Deviation from Nominal Auto Ranging Remote Control Interface Optional IEEE-488 Interface |
in stock | ||
| Quadtech | 1880 | Milliohmmeter 2 Mohms Down To 1 µohm | The Quadtech 1880 Milliohmmeter provides ease of use, digital display and excellent accuracy for performing low resistance measurements on switches, relays, connectors and a variety of other devices. The instrument offers a wide measurement range, from 1 µohm to 2 Mohms, with constant current ranging from 1 A to 1 µA. A built-in comparator makes the unit ideal for go/nogo testing in a production environment and is also adaptable for use in automated system applications with it's optional IEEE-488 interface.
Precision Measurements The 0.05% accuracy of the 1880 makes for consistent, reliable test results from this economically priced unit. Nine measurement ranges, automatic or manually selectable, provide wide coverage between 2 Mohms and 1 µohm with constant current between 1 µA and 1A. FEATURES: Measurement Range, 1 µohm to 2Mohm 1 µA to 1 A, Constant Current 0.05% Measurement Accuracy Measurement Speed of 5/second Easy to Read Digital Display Four-Terminal Kelvin Connections Automatic Zeroing Built-in Comparator for Go/NoGo Testing Display of % Deviation from Nominal Auto Ranging Remote Control Interface Optional IEEE-488 Interface |
http://www.kandelelex.com/jpegs/qt1880.jpg | in stock | |
| Quadtech | 1880 01 | Milliohmmeter 2 Mohms Down to 1 µohm | The Quadtech 1880 Milliohmmeter provides ease of use, digital display and excellent accuracy for performing low resistance measurements on switches, relays, connectors and a variety of other devices. The instrument offers a wide measurement range, from 1 µohm to 2 Mohms, with constant current ranging from 1 A to 1 µA. A built-in comparator makes the unit ideal for go/nogo testing in a production environment and is also adaptable for use in automated system applications with it's optional IEEE-488 interface.
Precision Measurements The 0.05% accuracy of the 1880 makes for consistent, reliable test results from this economically priced unit. Nine measurement ranges, automatic or manually selectable, provide wide coverage between 2 Mohms and 1 µohm with constant current between 1 µA and 1A. FEATURES: Measurement Range, 1 µohm to 2Mohm 1 µA to 1 A, Constant Current 0.05% Measurement Accuracy Measurement Speed of 5/second Easy to Read Digital Display Four-Terminal Kelvin Connections Automatic Zeroing Built-in Comparator for Go/NoGo Testing Display of % Deviation from Nominal Auto Ranging Remote Control Interface 01 = Optional IEEE-488 Interface |
http://www.kandelelex.com/jpegs/qt1880 01.jpg | ||
| Quadtech | 1910 | Inductance Analyzer | Features
Measures 15 Impedance Parameters, DC Resistance, Voltage and Current 0.1% Basic Measurement Accuracy 27,000 Programmable Frequencies from 20Hz to 1MHz AC Test Voltage Programmable from 20mV to 1V Internal DC Bias Current, Programmable from 0 to 1A Fast Measurement Speeds up to 40/Second Automatic Open/Short Zeroing Eliminates Connection Errors LCD Display for Menu Programming and Test Results 14 Hi/Lo Sorting Bins for Pass/Fail Testing RS-232, IEEE-488 and PLC Interfaces all Standard Results Displayed as Deviation or %Deviation from a Nominal Value Internal Storage and Recall of 30 Test Setups Monitor Voltage and Current to the Device Under Test Constant Voltage Maintained to the Device Under Test Ability to Automatically Perform 6 Unique Tests in Sequence Keypad Lockout Prevents Changes to the Test Setup Programmable Average and Delay Times Automatic Correction for Different Test Lead Lengths |
|||
| Quadtech | 2520 | Guardian AC/DC Hipot Tester 5KVAC / 6kVDC 15mA AC | The Guardian 2500 Series builds upon QuadTech’s Sentry family of electrical safety testers and incorporates a unique Ground Fault Interruption (GFI) feature as well as an RS232 interface and optional IEEE488 or enhanced remote interfaces. The GFI circuit is designed to protect the operator from inadvertent contact with the units high voltage output. The principle of operation is based on independent current monitoring on both the high voltage output and the return line. Any imbalance of current shuts the units high voltage output down.
The 2500 provides arc detection capability for monitoring short duration transients in current flow which often go undetected. Both detection level and duration of the arc are user programmable. The Guardian 2520 AC/DC Hipot Tester performs AC and DC dielectric withstand (hipot) tests. The test voltage is programmable in the range from 100V to 5KVAC/6KVDC with low and high current detection limits from 1µAAC to 15mAAC and 0.1µADC to 7.5mADC. The capability of measuring and displaying real, imaginary and total current makes the unit ideal for testing capacitive type devices, such as power supplies, cables and transformers, where the imaginary part of the total current may be significantly higher than the real part. |
in stock | ||
| Quadtech | 2530 40 | Gardian AC-DC-IR Hipot Tester 5KVAC 15mA 6KVDC 7.5 | The Gardian series hipot tester is designed to perform the most common electrical safety tests outlined in UL, TUV, IEC and other standards.
Features: *Programmable Output Voltage to 5KVAC and 6KVDC. *Output Current: 1uA to 15mAAC; .1uA to 7.5mADC *Ground Fault Interruption(GFI) for operator safety *Programmable Ramp, Test, and Fall Times *Storage of Test Setups; 25 user, 9 Multi-Step per Measurement *Continuous Leakage Current Moitoring to .1uA *Ground Continuity Test; 100mADC *Remote I/O, RS232, and GPIB *Insulation Resistance Measurements; 10kΩ to 1TΩ |
in stock | ||
| Quadtech | 6000 | Electrical Safety Analyzer 5KVAC 6KVDC 50Gohm 30A | The Guardian 6000 Electrical Safety Analyzer performs AC and DC hipot (hy-pot), insulation resistance, ground bond (continuity) and leakage current measurements for a complete dielectric testing solution. A fully automated tester, the 6000 performs both high voltage electrical safety tests including dielectric withstand and dielectric breakdown and high current ground bond tests in accordance with the requirements of UL 60950 and other product safety compliance standards.
Features AC Hipot: Programmable Voltage 50 to 5000VAC, Leakage Current to 40mA DC Hipot: Programmable Voltage 50 to 6000VDC, Leakage Current to 12mA Insulation Resistance: 100kΩ to 50GΩ, Test Voltage 50 to 1000VDC Ground Bond: Programmable Current to 30A, R Measurement to 510mΩ Twin Port – Simultaneous Hipot and Ground Bond Testing Open/Short Circuit Detection Mode Programmable Hi/Lo Limits for Pass/Fail Testing Ability to Perform Multiple Tests in Sequence Internal Storage and Recall of 100 Test Setups, 50 Steps Each Programmable Ramp, Dwell and Test Times Front Panel Lockout Prevents Changes to the Test Setup Automatic Offset to Zero Out Residual Current Fast Cutoff and Quick Discharge of Device Under Test RS-232 and I/O Interfaces Included Standard IEEE-488 and Printer Interfaces Optional Pause Mode Allows the Operator to Change Device Connection and Continue Built-In Operator Prompted Software Calibration Routine Front and Rear Panel Output Connections 40 Ground Bond Testing with Optional Transformer Multi-Point Testing with Optional Internal Scanner and/or External Scanners CaptivATE Automation Software for G6000 Plus; Optional CE, TUV Marked Option 03 - Plug-in scanner module with 8 channels for switching high voltage output from the tester. For use with Guardian 6000 and plugs into the instruments rear panel. |
in stock | ||
| Quadtech | 7000-05 | Chip Component Tweezers Accessory for 1689M-7400- | Chip component tweezers to 4 BNC, (1 meter in length) for handling and measuring surface mount devices (mdD) on the 74/7600. Maximum component size 14mm. | in stock | ||
| Quadtech | 7400 | Precision RLC Meter 10Hz - 500KHz | Measure and display any two of 14 parameters simultaneously. Measurement frequency: 10Hz to 500KHz with 229,900 programmable frequencies. Graphical and tabular display of swept frequency, voltage and current measurements with 7-digit resolution. 0.05% basic accuracy. Interfaces: GP-IB(optional), RS-232, handler, printer port, 3.5" floppy (DOS).
Features Measures 14 Impedance Parameters (2 simultaneously) 0.05% Basic Measurement Accuracy 229,900 Programmable Frequencies from 10Hz to 500KHz AC Test Voltage Programmable from 20mV to 5V DC Bias Voltage, 2V Internal or 0 to 200V External Fast Measurement Speeds up to 40/Second Automatic Open/Short Zeroing Eliminates Connection Errors High Resolution LCD with 7 Digit Display 14 Hi/Lo Sorting Bins for Pass/Fail Testing RS-232, IEEE-488, Printer, and PLC Interfaces all Standard Results Displayed as Deviation or %Deviation from a Nominal Value Internal Storage and Recall of Test Setups Constant Voltage Maintained to the Device Under Test Ability to Automatically Perform 6 Unique Tests in Sequence Keypad Lockout Prevents Changes to the Test Setup On site calibration with NIST Traceable Cal Kit Programmable Average and Delay Times |
in stock | ||
| Quadtech | 7400 | Precision RLC Meter 10Hz - 500KHz | Measure and display any two of 14 parameters simultaneously. Measurement frequency: 10Hz to 500KHz with 229,900 programmable frequencies. Graphical and tabular display of swept frequency, voltage and current measurements with 7-digit resolution. 0.05% basic accuracy. Interfaces: GP-IB(optional), RS-232, handler, printer port, 3.5" floppy (DOS).
Features Measures 14 Impedance Parameters (2 simultaneously) 0.05% Basic Measurement Accuracy 229,900 Programmable Frequencies from 10Hz to 500KHz AC Test Voltage Programmable from 20mV to 5V DC Bias Voltage, 2V Internal or 0 to 200V External Fast Measurement Speeds up to 40/Second Automatic Open/Short Zeroing Eliminates Connection Errors High Resolution LCD with 7 Digit Display 14 Hi/Lo Sorting Bins for Pass/Fail Testing RS-232, IEEE-488, Printer, and PLC Interfaces all Standard Results Displayed as Deviation or %Deviation from a Nominal Value Internal Storage and Recall of Test Setups Constant Voltage Maintained to the Device Under Test Ability to Automatically Perform 6 Unique Tests in Sequence Keypad Lockout Prevents Changes to the Test Setup On site calibration with NIST Traceable Cal Kit Programmable Average and Delay Times |
http://www.kandelelex.com/jpegs/qt7400.jpg | in stock | |
| Quadtech | 7600 | Precision LCR Meter 10Hz-2MHz .05% | The Quadtech 7600 LCR Meter is designed to perform precision impedance measurements over a wide frequency range, 10 Hz to 2 MHz. The instrument is capable of measuring 14 different parameters with 0.05% accuracy to meet today's requirements for component and material testing. The ease of use and user friendly menu programming makes the 7000 Series ideal for applications in product development, incoming inspections, or production line testing.
FEATURES: Frequency Range 10 Hz to 2 MHz 0.05% Basic Measurement Accuracy 7 Digit Measurement Resolution Programmable Test Voltage and Current Auto Ranging Test Setup and Measurement Data Storage Four-Terminal Kelvin Connections IEEE-488, RS-232, Handler, and Parallel Printer Interfaces Graphical and Tabular Display of Swept Frequency, Voltage and Current Measurements Sequence Testing of Up To 6 Individual Tests Load Correction Binning (15) Built-in Automatic Calibration Routine |
in stock | ||
| Quadtech | 7600 | Precision LCR Meter 10Hz-2MHz .05% | The Quadtech 7600 LCR Meter is designed to perform precision impedance measurements over a wide frequency range, 10 Hz to 2 MHz. The instrument is capable of measuring 14 different parameters with 0.05% accuracy to meet today's requirements for component and material testing. The ease of use and user friendly menu programming makes the 7000 Series ideal for applications in product development, incoming inspections, or production line testing.
FEATURES: Frequency Range 10 Hz to 2 MHz 0.05% Basic Measurement Accuracy 7 Digit Measurement Resolution Programmable Test Voltage and Current Auto Ranging Test Setup and Measurement Data Storage Four-Terminal Kelvin Connections IEEE-488, RS-232, Handler, and Parallel Printer Interfaces Graphical and Tabular Display of Swept Frequency, Voltage and Current Measurements Sequence Testing of Up To 6 Individual Tests Load Correction Binning (15) Built-in Automatic Calibration Routine |
http://www.kandelelex.com/jpegs/qt7600.jpg | in stock | |
| Quadtech | 7600A CE | Precicion LCR Meter with 500V Ext Bias CE Marked | The Quadtech 7600 LCR Meter is designed to perform precision impedance measurements over a wide frequency range, 10 Hz to 2 MHz. The instrument is capable of measuring 14 different parameters with 0.05% accuracy to meet today's requirements for component and material testing. The ease of use and user friendly menu programming makes the 7000 Series ideal for applications in product development, incoming inspections, or production line testing.
FEATURES: Frequency Range 10 Hz to 2 MHz 0.05% Basic Measurement Accuracy 7 Digit Measurement Resolution Programmable Test Voltage and Current Auto Ranging Test Setup and Measurement Data Storage Four-Terminal Kelvin Connections IEEE-488, RS-232, Handler, and Parallel Printer Interfaces Graphical and Tabular Display of Swept Frequency, Voltage and Current Measurements Sequence Testing of Up To 6 Individual Tests Load Correction Binning (15) Built-in Automatic Calibration Routine |
in stock | ||
| Quadtech | GUARDIAN 5000 | AC-DC-IR-GC Safety Analyzer (Hipot) .1-5KVAC .5-6K | The Quadtech Guardian 5000 Electrical Safety Analyzer is four instruments in one, providing AC Hipot, DC Hipot, Insulation Resistance, and Ground Bond measurements from a single test connector in one versatile instrument. This provides a cost effective solution to electrical safety compliance testing with maximum flexibility for present and future requirements. Performing all of the electrical safety tests in one box can reduce test time, increase productivity and reduce the number of boxes requiring calibration.
The Guardian 5000 AC Hipot Testerperforms AC dielectric testing (hipot) over the voltage range from 100V to 5000VAC RMS. The maximum leakage current of 40mA RMS makes the Guardian 5000 ideal for testing devices with high leakage currents such as power supplies which have large filter or “Y” capacitors for noise reduction. Both the actual test voltage and total current are displayed during testing. The Guardian 5000 DC Hipot Testervoltage range for DC dielectric testing is 100V to 6000VDC with a resolution of 10V. The maximum current leakage is 20mA which allows quick charging of capacitive devices. A quick discharge of the device when the measurement is complete, also minimizes test times. The Guardian 5000 Insulation Resistance measurements are similar to a DC hipot but rather than displaying leakage current, resistance is calculated and displayed. The insulation resistance can be measured over the range of 10MW to 10GW with test voltages from 50VDC to 1000VDC in 1V steps. The Guardian 5000 Ground Bondprovides up to 30A AC for ground bond testing. The test current can be programmed from 1A to 30A in 0.1A steps. Hi current limit, test time, frequency and open circuit no load voltage can all be programmed. The offset feature can automatically compensate for any lead resistance. Features of the Quadtech Guardian 5000 include: *Programmable output voltage to 5KV AC and 6KV DC *Ground Bond Testing to 30A AC with Adjustable Limit *Multi-point Scanner Option for High Voltage Switching of up to 64 Points *Programmable Ramp and Test Times *Storage of 50 Tests Setups with 15 Steps per Setup *Trip Current Programmable to 40mA AC and 20mA DC *Front Panel Lockout via Password *Standard IEEE and Remote Control Interfaces *Optional RS232 Interface *LabVIEW®Intrument Driver Software *Insulation Resistance Measurements from 10MW to 10GW 1ohm Limit Applications for the Quadtech Guardian include: *Production and Compliance Testing of Appliances, Instruments and Information Technology Equipment in Accordance with UL, CSA, IEC, TUV and Other Standards such as EN60335, EN60950, EN61010, CSA C22.2 No. 1010.1, UL3111 and UL1950 *Transformer Electrical Safety Testing *Electric Motor Safety Testing *Power Supply Safety Testing *Verification of the Ground Connection on Products with a Three Prong Power Cord |
in stock | ||
| Quadtech | GUARDIAN II | AC/DC Hipot Tester 100V - 5KVAC / 6kVDC | AC and DC hipot testing in one instrument with GPIB and user friendly menu driven interface. Output Voltage: 100V to 5KVAC(60Hz) and 100V to 6KVDC(+ grounded) with ±3% setting accuracy and 10V steps. Leakage Current: 0 to 10mA AC, 10uA/step and 0 to 5mA DC with ±2% accuracy. Trip current programmable 10uA to 10mA in 10uA steps. Test Time: manual or Auto(rise, hold and fall, 0 to 999sec). | in stock | ||
| Quadtech | GUARDIAN II | AC/DC Hipot Tester 100V - 5KVAC / 6kVDC | AC and DC hipot testing in one instrument with GPIB and user friendly menu driven interface. Output Voltage: 100V to 5KVAC(60Hz) and 100V to 6KVDC(+ grounded) with ±3% setting accuracy and 10V steps. Leakage Current: 0 to 10mA AC, 10uA/step and 0 to 5mA DC with ±2% accuracy. Trip current programmable 10uA to 10mA in 10uA steps. Test Time: manual or Auto(rise, hold and fall, 0 to 999sec). | http://www.kandelelex.com/jpegs/qtguardian ii.jpg | in stock | |
| Quadtech | LR2000 | Milliohmmeter 1μΩ - 2MΩ 0.05% Accuracy | The LR2000 Milliohmmeter with its LCD display and menu-type front
panel programming assures that low resistance measurements on switches, relays, cables, and other devices can be made quickly and easily. With a basic accuracy of 0.05% the instrument offers a wide measurement range from 1μohm to 2Mohms. For remote operation and production applications the unit comes standard with an RS-232 interface, plus IEEE-488 and handler interfaces are available as options. For measurement integrity, contact to the test device is made via a 4-terminal Kelvin connection that incorporates an automatic zeroing function to compensate for lead errors. FEATURES: • 1μΩ - 2MΩ Measurement Range • 1μA - 1A Constant Current • 0.05% Basic Measurement Accuracy • Measurement Speed to 15/second • Graphical LCD Display • Four Terminal Kelvin Connection • Automatic Zeroing • Automatic Hi/Lo Comparator Limits • Pass/Fail Sorting (8 Bins) • Voltage Limiting for Dry Contact Testing • Signal Reverse & Pulsed Current Modes • Keypad Lockout • Programmable Delay Times • RS-232 Interface Standard • IEEE & Handler Interfaces, Optional • Temperature Compensation Interface, Optional |
|||
| Quadtech | SENTRY 10 PLUS | AC Hipot Tester 50V to 5KVAC 1uA to 20mA | Description
The Sentry 10 Plus AC Hipot Tester (CE Mark) performs AC dielectric withstand (hipot) tests. The test voltage is programmable from 50V to 5kV AC with a resolution of 1V. The current range is 1µA to 20mA. Program & Display Ground Continuity: The Sentry Plus Series can measure and display the resistance between the ground blade of the power cord and any exposed metal on the product. Meets UL Hipot Tester Requirements: The Sentry Plus instruments measure & display the output voltage directly at the output terminals. The instruments have both visual and audible failure indications, and after a failure the STOP switch must be pressed prior to another measurement. Features *AC Hipot Voltage 50 to 5000V, Output Current to 20mA *Programmable Ground Continuity Check, 0.1 to 5ohms *Programmable Ramp, Test, and Fall Times *Fast Cutoff and Discharge of Device Under Test *Programmable Hi/Lo Limits for Pass/Fail Testing *Large LCD Display for Menu Programming and Test Results *Internal Storage and Recall of 80 Test Setups *Ground Fault Interrupt Shutdown for Operator Safety *Front and Rear Panel Output Connections *Front Panel Lockout Prevents Changes to the Test Setup *Automatic Offset to Zero Out Stray Leakage Current *Instruments Upgradeable, Sentry 10 to 20 to 30 *3mA Current Limit per EN50191 *UL Listed and CE Marked |
in stock | ||
| Quadtech | SENTRY 30 | AC/DC/IR Hipot Tester .1MΩ-50GΩ 50-5KVDC@5mA 50-6K | The Sentry 30 Plus AC/DC/IR Hipot Tester (CE Mark) has all of the features of the Sentry 20 Plus in addition to Insulation Resistance (IR) testing. The IR measurement range is from 0.1MΩ to 50GΩ with test voltages from 50 to 1000VDC.
Program & Display Ground Continuity: The Sentry Plus Series can measure and display the resistance between the ground blade of the power cord and any exposed metal on the product. Features *AC Hipot Voltage 50 to 5000V, Output Current to 20mA *DC Hipot Voltage 50 to 6000V, Output Current to 5mA *IR Measurements 100kohms to 50Gohms, Test Voltage 50 to 1000VDC *Programmable Ground Continuity Check, 0.1 to 5ohms *Programmable Ramp, Test, and Fall Times *Fast Cutoff and Discharge of Device Under Test *Programmable Hi/Lo Limits for Pass/Fail Testing *Large LCD Display for Menu Programming and Test Results *Internal Storage and Recall of 80 Test Setups *Ground Fault Interrupt Shutdown for Operator Safety *Front and Rear Panel Output Connections *Front Panel Lockout Prevents Changes to the Test Setup *Automatic Offset to Zero Out Stray Leakage Current *Instruments Upgradeable, Sentry 10 to 20 to 30 *3mA Current Limit per EN50191 |
|||
| Quadtech | SENTRY10 | AC Hipot Tester 0-5kVAC 20ma | The Sentry 10 AC Hipot Tester (CE Mark) performs AC dielectric withstand (hipot) tests. The test voltage is programmable from 50V to 5kV AC with a resolution of 1V. The current range is 1µA to 20mA. | in stock | ||
| Quadtech | SENTRY10 | AC Hipot Tester 0-5kVAC 20ma | The Sentry 10 AC Hipot Tester (CE Mark) performs AC dielectric withstand (hipot) tests. The test voltage is programmable from 50V to 5kV AC with a resolution of 1V. The current range is 1µA to 20mA. | http://www.kandelelex.com/jpegs/qtsentry10.jpg | in stock | |
| Quantum Data | 801A | Video Character Generator | Programmable RGB video test generator for servicing color monitors. 16 Selectable color patterns. Programmable dot clock range of 1.024-32.768MHz color, 65.520MHz monochrome. | |||
| Racal Dana | 1260-12 | 20-Channel DPDT 220V 2A Switch Card | in stock | |||
| Racal Dana | 1260-13 | 40-channel Dpst220v 2A Switch Card | ||||
| Racal Dana | 1260-35A | 2-Wire 1 x 96 Multiplexer Card | in stock | |||
| Racal Dana | 1261E | VXI Mainframe | in stock | |||
| Racal Dana | 1992 | Universal Frequency Counter DC - 1.3GHz | Half-rack unit features 9-digit resolution in 1 second. Channel A: 0 to 160MHz with 25mV sensitivity up to 100MHz(50mV to 160MHz). Channel C: 40MHz to 1.3GHz with 10mV sensitivity up to 1GHz(75mV to 1.3GHz). GP-IB available. | |||
| Racal Dana | 9087 | Synthesized Signal Generator 10KHz - 1300MHz | http://www.kandelelex.com/jpegs/rac9087.jpg | in stock | ||
| Radio Frequency Labs | 912 | Gauss Meter And Probe | Where high sensitivity and wide measurement range are required. Includes 7199 probe. | |||
| Ransco Environmental | 925 | Hot / Cold Temperature Chamber | Temperature range: -73 to +273°C; Dimensions: Inside; 10.5D x 14.5"W x 8.75"H; Exterior; 21"H x 19"D x 19"W, rack mount unit. CO2 or LN2 cooling. Forced draft. Stainless steel interior. Single set point controller with digital readout of temperature. Programmable via RS-232C interface. | in stock | ||
| Raytheon | 370708 | Shielded Room Leak Detector | Portable system includes a transmitter, receiver, articulated receiver probe, probe extension, and transmitter cable set housed in a transit case. Transmitter: 95KHz (crystal controlled); 16 watts peak, high range, 1.6 watts peak, low range. Modulated: 100% @ 1KHz. Receiver: 0-40dB meter indication. Internal speaker.Input attenuator: 10 steps of 10dB each. Tuned antenna input circuit. | in stock | ||
| Reichert Jung (Leica) | 312508 | Photographic Microscope | This is a trinocular head microscope with base light. We will try to answer your questions reguarding this unit. | http://www.kandelelex.com/jpegs/rei312508.jpg | in stock | |
| Reichert Jung (Leica) | 569B | Stereo Star Zoom Microscope | Magnification: .7 to 3X. Similar to B & L StereoZoom 4. | http://www.kandelelex.com/jpegs/rei569b.jpg | in stock | |
| Research Devices | D | Infrared Microscope | System includes 20X and 6X lenses mounted on a 4-turrett base with infrared light source and a standard light source. Eyepeices and power supplies are missing. | in stock | ||
| Research Devices | NC-67X | Camera And Power Supply | BNC video and vertical sync connectors. | in stock | ||
| RF Industries | RFA-4013 | 7/16 DIN Adapter Kit | in stock | |||
| Riser Bond | 1205TX-OSP | Metallic TDR Cable Fault Locator | Dual Input, Combination Short/Long Range Metallic Time Domain Reflectometer Cable Fault Locator Optimized for Loaded Cable Systems. Test loaded cables up to 80 miles - 130 km! Two line, live input for cable comparison. Automatic crosstalk measurement capability. Automatic fault severity calculation. Exclusive RANGE-PLUST function. Exclusive SUPER-STORET waveform storage. Intermittent Fault Detection mode detects and displays intermittent faults and allows the operator to adjust and reposition the waveform without affecting the IFD function. Multi-function noise filters. Unique dual independent cursors. Automatic and manual cursor placement functions. Powered cable warning. Compact, lightweight, and portable OSP packaging. | http://www.kandelelex.com/jpegs/rb1205tx-osp.jpg | ||
| Riser Bond | 1270 | TDR Metallic Time Domain Reflectometer Cable Fault | Metallic Time Domain Reflectometer Cable Fault Locator. The ultimate combination TDR for testing both twisted pair and coaxial cables.
Using Model 1270A results in superior fault location in any industry and any application. Sub-nanosecond pulse width in coaxial mode locates small, often unsuspected, faults that are close together. RANGE-PLUS simplifies keypad operation by combining a specific pulse width, vertical gain, and cable length. Live waveform testing. Intermittent Fault Detection mode detects and displays intermittent faults and allows the operator to manipulate and reposition the waveform without affecting the IFD function. Noise filters for eliminating unwanted waveform noise. Rugged, weatherproof packaging. Compact, lightweight, portable. |
http://www.kandelelex.com/jpegs/rb1270.jpg | ||
| Riser Bond | 1550 | Metallic Time Domain Reflectometer Cable Fault Loc | Metallic Time Domain Reflectometer Cable Fault Locator
The Riser Bond 1550 is an easy to use handheld entry level TDR. It is optimized to help the field engineer find the most common first line faults, the Riser Bond 1550 can be used across a broad range of applications including telecom, CATV and power. The unit provides both short range and long range faultfinding capability.The unit has advanced features such as a patented timing circuit and swept gain for ease of fault identification. It has been designed with ease of use and accuracy to provide the operator with an unparalleled level of performance to mitigate typical service affecting faults. Key features *Universal applications unit. *Ease of use. *Swept gain algorithm. *33 ft (10 m) to 9800 ft (3000 m) |
in stock | ||
| Rod-L Electronics | M100AVS5-1.5-50 | AC Hipot Tester 1.5kV 50mA | Performs concurrent dielectric withstand and ground continuity test in a single operation, complying with UL, CSA, IEC, VDE, and FCC Test Voltage: 0 to 1.5kvac. Output Current: 50mA, adjustable trip point. | in stock | ||
| Rod-L Electronics | M100AVS5-1.5-50 | AC Hipot Tester 1.5kV 50mA | Performs concurrent dielectric withstand and ground continuity test in a single operation, complying with UL, CSA, IEC, VDE, and FCC Test Voltage: 0 to 1.5kvac. Output Current: 50mA, adjustable trip point. | http://www.kandelelex.com/jpegs/rdlm100avs5-1.5-50.jpg | in stock | |
| Rod-L Electronics | M100AVS5-1-10 | Hipot 1KV 10mA | in stock | |||
| Rod-L Electronics | M100AVS5-2.8-40 | Hipot Tester | Performs concurrent dielectric withstand and ground continuity test in a single operation, complying with UL, CSA, IEC, VDE, and FCC. Test Voltage: 0 to 2.8kvac. Output Current: 40mA, adjustable trip point. | in stock | ||
| Rod-L Electronics | M100AVS5-2.8-40 | Hipot Tester | Performs concurrent dielectric withstand and ground continuity test in a single operation, complying with UL, CSA, IEC, VDE, and FCC. Test Voltage: 0 to 2.8kvac. Output Current: 40mA, adjustable trip point. | http://www.kandelelex.com/jpegs/rdlm100avs5-2.8-40.jpg | in stock | |
| Rod-L Electronics | M100AVS5-50-25 | AC Hipot Tester 5kV 25ma | Performs concurrent dielectric withstand and ground continuity test
in a single operation, complying with UL, CSA, IEC, VDE, and F.C.C. Test Voltage: 0 to 5.0kVAC. Output Current: 25mA, adjustable trip point. |
http://www.kandelelex.com/jpegs/RDLM100AVS5-50-25.jpg | ||
| Rod-L Electronics | M100BVS5-2.8-40 | Hipot Tester | Performs concurrent dielectric withstand and ground continuity test in a single operation, complying with UL, CSA, IEC, VDE, and FCC. Test Voltage: 0 to 2.8kvac. Output Current: 40mA, adjustable trip point. "BV" models have Real(Resistive) Current measurement(to null capacitive current). | in stock | ||
| Rod-L Electronics | M100BVS5-2.8-40 | Hipot Tester | Performs concurrent dielectric withstand and ground continuity test in a single operation, complying with UL, CSA, IEC, VDE, and FCC. Test Voltage: 0 to 2.8kvac. Output Current: 40mA, adjustable trip point. "BV" models have Real(Resistive) Current measurement(to null capacitive current). | http://www.kandelelex.com/jpegs/rdlm100bvs5-2.8-40.jpg | in stock | |
| Rod-L Electronics | M100BVS5-5.0-25 | AC Hipot 0 - 5KV 0 - 25mA | All ROD-L hipot testers have adjustable electronically controlled test voltage ramp control and timing circuits. In addition, ROD-L AC and DC hipot testers interconnect to simplify multiple testing requirements. Each are compatible with all ROD-L Ground Continuity and Leakage Current test instruments.
The ROD-L Hipot testers are designed to perform the tests specified by UL, IEC, CSA, VDE, FCC and others. The ROD-L product line has been designed with emphasis on safety, efficiency, and on speed with which the test can be made. Specifications: Output Voltage: 0-5000VAC Output Current: 0-25mA Ramp Time V: 1 to 30 seconds, user adjustable Test Time: 1 to 90 seconds, user adjustable Shutdown: 2 milliseconds Arc Detection: Arc duation 10 milliseconds or greater AC Input: 115/230VAC 48-66Hz |
in stock | ||
| Rod-L Electronics | M100BVS5-5.5-25 | AC Hipot Tester 5.5kVAC 25mA | Performs concurrent dielectric withstand and ground continuity test in a single operation, complying with UL, CSA, IEC, VDE, and FCC. Test Voltage: 0 to 5.5kvac. Output Current: 25mA, adjustable trip point. "BV" models have Real(Resistive) Current measurement(to null capacitive current). | http://www.kandelelex.com/jpegs/rdlm100bvs5-5.5-25.jpg | in stock | |
| Rod-L Electronics | M100DC-5.5-100 | Hipot Tester 0 - 5.5kVDC 0 - 100ma | in stock | |||
| Rod-L Electronics | M100DC-5.5-100 | Hipot Tester 0 - 5.5kVDC 0 - 100ma | http://www.kandelelex.com/jpegs/rdlm100dc-5.5-100.jpg | in stock | ||
| Rod-L Electronics | M100DC-5.5-5 | DC Hipot Tester | Output Voltage: 0-5.5KVDC. Output Current: 0-5mA. Ramp Time: 50v/sec to 5000v/sec. Test Time: 1s to 90sec. Detects and Indicates chassis ground, test in progress, test passed, test failed. Full compliance with UL, VDE, BSI, IEC, CSA, and other test standards. | in stock | ||
| Rod-L Electronics | M100DC-5.5-5 | DC Hipot Tester | Output Voltage: 0-5.5KVDC. Output Current: 0-5mA. Ramp Time: 50v/sec to 5000v/sec. Test Time: 1s to 90sec. Detects and Indicates chassis ground, test in progress, test passed, test failed. Full compliance with UL, VDE, BSI, IEC, CSA, and other test standards. | http://www.kandelelex.com/jpegs/rdlm100dc-5.5-5.jpg | in stock | |
| Rod-L Electronics | M1088 | IEEE-488 Bus Interface | Provides GP-IB interfacing between computer/controllers and Rod-L hipot, ground continuity, and insulation testers. Option 19 required on testers. | in stock | ||
| Rod-L Electronics | M25 | Ground Continuity Tester | Performs ground continuity tests in compliance with BSI, VDE, CSA, and IEC regulations. Output: 2.5 volts AC, up to 25 amps. Variable test times adjustable from 1 second to 90 seconds. Failures are identified by audible and visual alarms. | in stock | ||
| Rod-L Electronics | M25 | Ground Continuity Tester | Performs ground continuity tests in compliance with BSI, VDE, CSA, and IEC regulations. Output: 2.5 volts AC, up to 25 amps. Variable test times adjustable from 1 second to 90 seconds. Failures are identified by audible and visual alarms. | http://www.kandelelex.com/jpegs/rdlm25.jpg | in stock | |
| Rod-L Electronics | M30 | 30 Amp Ground Continuity Tester | Performs ground continuity tests in full compliance with BSI, VDE, and IEC. Test time is adjustable from 1 second to 90 seconds. Output Current: 30 amperes. Resistance: 0 to 0.15 ohms, accurate to ± 5% fs. Test Time: 1 second to 90 seconds. | http://www.kandelelex.com/jpegs/rdlm30.jpg | in stock | |
| Rod-L Electronics | M35 | Ground Fault Tester 35 Amp | Ground Continuity Test Instrument
Safe, Fast, Efficient Performs ground continuity tests in full compliance with BSI, VDE and IEC Test time is adjustable from 1 second to 90 seconds Measures AC resistance from Chassis of Device Under Test (DUT) to power-cord ground lead - 0 to 0.15 ohm Audible and visual alarms identify faulty ground connections Hipot interface enables interconnecting to any ROD-L ROD-L Hipot Test Instrument to form an automatic test system AC power source supplies 35 Amps (user specified) at Ĺ 2.5 volts |
in stock | ||
| Rod-L Electronics | M35 | Ground Fault Tester 35 Amp | Ground Continuity Test Instrument
Safe, Fast, Efficient Performs ground continuity tests in full compliance with BSI, VDE and IEC Test time is adjustable from 1 second to 90 seconds Measures AC resistance from Chassis of Device Under Test (DUT) to power-cord ground lead - 0 to 0.15 ohm Audible and visual alarms identify faulty ground connections Hipot interface enables interconnecting to any ROD-L ROD-L Hipot Test Instrument to form an automatic test system AC power source supplies 35 Amps (user specified) at Ĺ 2.5 volts |
http://www.kandelelex.com/jpegs/rdlm35.jpg | in stock | |
| Rod-L Electronics | M500AVS5-1.5-350 | AC Hipot Tester 0 - 1.5KV 0 - 350mA | The M100/500 Series of AC Hipot Test Instruments is intended for production, receiving inspection and laboratory applications. Each instrument in the series performs safe and efficient testing, and in full compliance to UL, VDE, BSI, CSA, etc. test requirements.
Features: Performs both AC Insulation breakdown and AC concurrent ground continuity tests Solid state voltage control circuitry - zero crossing start 2-millisecond voltage shutdown - without voltage spikes Full compliance with UL, VDE, BSI, IEC and CSA test standards UL listed |
in stock | ||
| Rod-L Electronics | M500AVS5-2.8-100 | AC Hipot Tester 2.8kVAC 100ma | Performs concurrent dielectric withstand and ground continuity test in a single operation, complying with U.L., C.S.A., I.E.C., V.D.E., and F.C.C. Test Voltage: 0 to 2.8kvac. Output Current: 100mA, adjustable trip point. | in stock | ||
| Rod-L Electronics | M500AVS5-2.8-100 | AC Hipot Tester 2.8kVAC 100ma | Performs concurrent dielectric withstand and ground continuity test in a single operation, complying with U.L., C.S.A., I.E.C., V.D.E., and F.C.C. Test Voltage: 0 to 2.8kvac. Output Current: 100mA, adjustable trip point. | http://www.kandelelex.com/jpegs/rdlm500avs5-2.8-100.jpg | in stock | |
| Rod-L Electronics | M500AVS5-5.0-100 | AC Hipot Tester 0-5kVAC 0-100ma | ||||
| Rod-L Electronics | M500AVS5-5.0-100 | AC Hipot Tester 0-5kVAC 0-100ma | http://www.kandelelex.com/jpegs/rdlm500avs5-5.0-100.jpg | |||
| Rod-L Electronics | M500AVS5-50-100 | AC Hipot 100v-5kV 100ma | ||||
| Rod-L Electronics | M500AVS5-50-100 | AC Hipot 100v-5kV 100ma | http://www.kandelelex.com/jpegs/rdlm500avs5-50-100.jpg | |||
| Rod-L Electronics | M500BVS5-28-200 | AC Hipot 2.8kV 200ma | Performs concurrent dielectric withstand and ground continuity test in a single operation, complying with UL, CSA, IEC, VDE, and FCC. Test Voltage: 0 to 2.8kvac. Output Current: 200mA, adjustable trip point. | http://www.kandelelex.com/jpegs/rdlm500bvs5-28-200.jpg | ||
| Rod-L Electronics | M500BVS5-50-100 | AC Hipot 5kV 100ma | Performs concurrent dielectric withstand and ground continuity test in a single operation, complying with UL, CSA, IEC, VDE, and FCC. Test Voltage: 0 to 5kvac. Output Current: 100mA, adjustable trip point. | http://www.kandelelex.com/jpegs/rdlm500bvs5-50-100.jpg | ||
| Rohde & Schwarz | AMIQ03 B2-B3-K11 | The I/Q Modulation Generator AMIQ and the Simulation Software WinIQSIMT open up new dimensions for the generation of I/Q signals. The AMIQ is a dual-channel modulation generator that has consequently been designed for use as an I/Q source. It is programmed and set with the Software WinIQSIMT. The AMIQ outputs I/Q baseband signals or even can generate an IF signal (up to 25 MHz).
Each channel can store 4 000 000 samples (AMIQ04 up to 16 000 000 samples). Even at high symbol rates sequences of sufficient length can thus be generated. With clock frequencies of up to 100 Msample/s and a high amplitude resolution of 14 bits (16 bits resolution with digital output, option AMIQ-B3), AMIQ is the ideal source for any signal in the world of digital modulation. An automatic amplitude/offset alignment as well as fine adjustment of the skew provide excellent symmetry of the two channels which previously was extremely difficult to attain with dual-channel ARB generators. The error vector can thus be minimised. A typical application of AMIQ and WinIQSIMT is not only to drive the I/Q inputs of a vector signal generator but also for baseband applications, e.g. for testing I/Q modulators/demodulators. The option AMIQ-B2 provides the inverted outputs for I and Q in addition to the I/Q outputs of the standard AMIQ. The differential outputs are useful for tests of components with differential inputs. The AMIQ-B3 digital I/Q output option supplies the up to 16-bit data bus for both channels I and Q at a 68-pin front-panel connector on the AMIQ basic unit. The associated bit clock is supplied in addition. Traces generated with WinIQSIMT version 3.10 and higher have a resolution of 14 bits or 16 bits. Option AMIQ-K11, IS-95 CDMA Software option for interpreting a waveform file generated according to IS95 by WinIQSIMT, version 2.10 or higher. The option is enabled by means of a key number so that the instrument doesn't have to be opened. |
||||
| Rohde & Schwarz | AMIQ03 K11 | I/Q Modulation Generator | he I/Q Modulation Generator AMIQ and the Simulation Software WinIQSIMT open up new dimensions for the generation of I/Q signals. The AMIQ is a dual-channel modulation generator that has consequently been designed for use as an I/Q source. It is programmed and set with the Software WinIQSIMT. The AMIQ outputs I/Q baseband signals or even can generate an IF signal (up to 25 MHz).
Each channel can store 4 000 000 samples (AMIQ04 up to 16 000 000 samples). Even at high symbol rates sequences of sufficient length can thus be generated. With clock frequencies of up to 100 Msample/s and a high amplitude resolution of 14 bits (16 bits resolution with digital output, option AMIQ-B3), AMIQ is the ideal source for any signal in the world of digital modulation. An automatic amplitude/offset alignment as well as fine adjustment of the skew provide excellent symmetry of the two channels which previously was extremely difficult to attain with dual-channel ARB generators. The error vector can thus be minimised. A typical application of AMIQ and WinIQSIMT is not only to drive the I/Q inputs of a vector signal generator but also for baseband applications, e.g. for testing I/Q modulators/demodulators. The option AMIQ-B2 provides the inverted outputs for I and Q in addition to the I/Q outputs of the standard AMIQ. The differential outputs are useful for tests of components with differential inputs. The AMIQ-B3 digital I/Q output option supplies the up to 16-bit data bus for both channels I and Q at a 68-pin front-panel connector on the AMIQ basic unit. The associated bit clock is supplied in addition. Traces generated with WinIQSIMT version 3.10 and higher have a resolution of 14 bits or 16 bits. Option AMIQ-K11, IS-95 CDMA Software option for interpreting a waveform file generated according to IS95 by WinIQSIMT, version 2.10 or higher. The option is enabled by means of a key number so that the instrument doesn't have to be opened. |
in stock | ||
| Rohde & Schwarz | AMIQ04 | Waveform Generator | 14-bit amplitude resolution; 4,000,000 samples memory depth; 100 MHz sample rate. Two signal outputs (I and Q). Integrated hard disk and floppy disk drive. | |||
| Rohde & Schwarz | CMD55 B3-4-5-6-9-19-41-42-43-44-61-62 | Communications Test Set | Features of the Rohde & Schwarz CMD55 Digital Radiocommunication Tester:
Mobile Phone Tester for all GSM bands (GSM900/1800/1900) Cost-effective solution for production lines Extremely fast IEEE-bus operation for high production throughput Versatile measurements for R&D and TQM High flexibility due to a various choice of parameter settings Full dynamic power ramp measurements according to GSM Recs Very fast spectrum due to modulation measurements with 5-pole filter prepared for measurements of DECT Fixed and Portable Parts (ETSI Rec. CTR06) Options: CMD-B3 Multifrequency reference input/output. For synchronizing DUT and measuring instrument with internal or external frequencies. Allows synchronization of CMD to an internal or external frequency of 2.048, 10, 13, 26, 39, 52 MHz, or to the GSM bit clock. CMD-B4 Fast power ramp, phase/frequency error & BER measurement. Provides fast testing and numeric/graphic display of power bursts and phase / frequency error as well as various BER, RBER and FER test routines (necessary for Autotest) Required for options CMD-B41, CMD-B42, CMD-B43, CMD-B44 and CMD-K43 CMD-B41 Includes audio frequency (AF) generator, voltmeter, distortion meter and frequency counter. Allows measurements on the audio interface or on modules. Enables frequency measurements up to 60 MHz which is required for LO alignment Requires CMD-B4 CMD-B42 High dynamic range burst analyzer. Enhances the dynamic range to more than72 dB and allows the power ramp to be measured in the entire specified GSM, GSM1800 and GSM1900 range. Determines whether transmitter blanking in inactive time slots is correct. Requires CMD-B4 CMD-B43 Carries out GSM measurements of spectrum due to switching and modulation according to the GSM, GSM1800 and GSM1900 recommendations faster than any spectrum analyzer Requires CMD-B4 and CMD-B42. Requires CMD-B4 and CMD-B42 CMD-B44 Audio multitone option based on DSP techniques. Makes it possible to generate and measure up to 14 tones in about a second. Useful for loudness rating, frequency response and intermodulation analysis Requires CMD-B4 and CMD-B41 CMD-B6 CMD-B6 Adapters for B6x options. Provides GSM specific signals and trigger signals for CMD52/55/65 on the multifunction connector at the front of the instrument. Requires for options CMD-B61 and CMD-B62 CMD-B61 IEC/IEEE 488-bus interface. Remote control alternative to the RS-232-C interface fitted as standard. Used for fast remote control of CMD. Requires CMD-B6 CMD-B62 Memory card interface. Allows storage of instrument setups and fast and easy upgrade to new software features. Highly recommended Requires CMD-B6 |
http://www.kandelelex.com/jpegs/r&scmd55 b3-4-5-6-9-19-41-42-43-44-61-62.jpg | in stock | |
| Rohde & Schwarz | CMD80 | Communications Test Set | Supports: CDMA(800/1800/1900MHz bands), IS-136, AMPS, NAMPS, ETACS, NTACS, JTACS. Large LCD display. Cellular and PCS frequencies. Dual-mode CDMA/Analog measurements. Memory card interface. Options: B1,B3,B14,B60,ˇ B61,B81,B82,K2. | in stock | ||
| Rohde & Schwarz | CMD80 | Communications Test Set | Supports: CDMA(800/1800/1900MHz bands), IS-136, AMPS, NAMPS, ETACS, NTACS, JTACS. Large LCD display. Cellular and PCS frequencies. Dual-mode CDMA/Analog measurements. Memory card interface. Options: B1,B3,B14,B60,ˇ B61,B81,B82,K2. | http://www.kandelelex.com/jpegs/r&scmd80.jpg | in stock | |
| Rohde & Schwarz | CMD80 B1-B3-B14-B60-B61-B62-B81-B82-B84-K1-K2 | Communications Test Set | Supports: CDMA(800/1800/1900MHz bands), IS-136, AMPS, NAMPS, ETACS, NTACS, JTACS. Large LCD display. Cellular and PCS frequencies. Dual-mode CDMA/Analog measurements. Memory card interface. Options: B1,B3,B14,B60,ˇ B61,B81,B82,K2. | http://www.kandelelex.com/jpegs/R&SCMD80 B1-B3-B14-B60-B61-B62-B81-B82-B84-K1-K2.jpg | in stock | |
| Rohde & Schwarz | CMD80 B1-B3-B14-B60-B61-B62-B81-B82-K1-K2 | Communications Test Set | Supports: CDMA(800/1800/1900MHz bands), IS-136, AMPS, NAMPS, ETACS, NTACS, JTACS. Large LCD display. Cellular and PCS frequencies. Dual-mode CDMA/Analog measurements. Memory card interface. Options: B1,B3,B14,B60,ˇ B61,B81,B82,K2. | in stock | ||
| Rohde & Schwarz | EMFT | TV Test Receiver | The Rohde & Schwarz EMFT TV Test Receiver is a continuously tunable test receiver that features two isolated video outputs and two outputs for the Q signal. These outputs enable the measurement of incidental phase modulation of the vision carrier which in turn determines the intercarrier S/N ration of the sound channel.
In addition, the adjustment of linearity and phase equalizing circuits is facilitated through the use of the Q signal. The EMFT is fitted with an audio broadband output which delivers a multiplex signal for driving an MTS decoder. Moreover, a 4.5 MHz intercarrier input and output are provided. A front panel switch permits selection of envelope or synchronous detection. The RF input voltage and the frequency deviation of the sound carriers are indicated on the analog meter. The sound level is monitored by means of a built-in loudspeaker. The EMFT receiver features channel selection with digital entry of channel number either in manual or in remote mode (optional). The receiver can control the frequency offset up to +/- 100 kHz and is continuously tunable in all TV bands. |
in stock | ||
| Rohde & Schwarz | FSH6 | Hand-Held Spectrum Analyzer with Preamplifier 100K | The Rohde & Schwarz FSH6 is the ideal spectrum analyzer for rapid, high-precision, cost-effective signal investigations. It provides a large number of measurement functions to handle anything from the installation or maintenance of a mobile radio base station, to on-site fault location in RF cables, to development and service.
*Frequency range 100 kHz to 6 GHz *Internal preamplifier with frequency range from 100 kHz to 6 GHz *Displayed average noise level typical -135 dBm (RBW 100 Hz) 0.5 dB typ. level accuracy up to 6 GHz *Resolution bandwidths 100 Hz to 1 MHz, 1 and 3 steps *Wide range of detectors: sample, max/min peak, auto peak, RMS Supplied with FSH-Z37 Optical USB interface cable, 1.5 m |
in stock | ||
| Rohde & Schwarz | FSU26 B10-B23-B25 | Spectrum Analyzer 20Hz-26GHz | The R&S FSU spectrum analyzers are performance leaders in dynamic range, phase noise, level accuracy, and resolution bandwidth - all factors that are essential for the user's ability to design, characterize, and manufacture next generation wireless elements.
Frequency range 20 Hz to 26.5 GHz Displayed average noise level -158 dBm (1 Hz) Phase noise -123 dBc (1 Hz) at 10 kHz TOI typ. +25 dBm Resolution bandwidth 1 Hz to 50 MHz Fast ACP in time domain Up to 70 measurements per second (including trace transfer via GPIB) Measurement routines for TOI, MC ACP(R), OBW, CCDF, APD, etc. as standard |
|||
| Rohde & Schwarz | FSU26 B10-B23-B25 | Spectrum Analyzer 20Hz-26GHz | The R&S FSU spectrum analyzers are performance leaders in dynamic range, phase noise, level accuracy, and resolution bandwidth - all factors that are essential for the user's ability to design, characterize, and manufacture next generation wireless elements.
Frequency range 20 Hz to 26.5 GHz Displayed average noise level -158 dBm (1 Hz) Phase noise -123 dBc (1 Hz) at 10 kHz TOI typ. +25 dBm Resolution bandwidth 1 Hz to 50 MHz Fast ACP in time domain Up to 70 measurements per second (including trace transfer via GPIB) Measurement routines for TOI, MC ACP(R), OBW, CCDF, APD, etc. as standard |
http://www.kandelelex.com/jpegs/r&sfsu26 b10-b23-b25.jpg | ||
| Rohde & Schwarz | FSU26 B18-B23-B25 | Spectrum Analyzer 20 Hz - 26.5 GHz | The R&S FSU spectrum analyzers are performance leaders in dynamic range, phase noise, level accuracy, and resolution bandwidth - all factors that are essential for the user's ability to design, characterize, and manufacture next generation wireless elements.
Frequency range 20 Hz to 26.5 GHz Displayed average noise level -158 dBm (1 Hz) Phase noise -123 dBc (1 Hz) at 10 kHz TOI typ. +25 dBm Resolution bandwidth 1 Hz to 50 MHz Fast ACP in time domain Up to 70 measurements per second (including trace transfer via GPIB) Measurement routines for TOI, MC ACP(R), OBW, CCDF, APD, etc. as standard Options: B18 - Removable hard disk B23 - Preamplifier 20dB 3.6 to 26GHz B25 - Electronic Attenuator, 0 dB to 30 dB, and 20 dB Preamplifier (3.6 GHz) |
|||
| Rohde & Schwarz | FSU26 B4-B23-B25-K5-K7-K8-K30-K73-K83-K84 | Spectrum Analyzer 20Hz-26GHz | Frequency range 20 Hz to 26.5 GHz
Displayed average noise level -158 dBm (1 Hz) Phase noise -123 dBc (1 Hz) at 10 kHz TOI typ. +25 dBm Resolution bandwidth 1 Hz to 50 MHz Fast ACP in time domain Up to 70 measurements per second (including trace transfer via GPIB) Measurement routines for TOI, MC ACP(R), OBW, CCDF, APD, etc. as standard Options: B4 - OCXO 10MHz High Stability Timebase; B23 - Preamplifier 20dB 3.6 to 26GHz; B25 - Electronic Attenuator, 30dB Preamplifier, 10MHz to 3.6GHz; K5 - GSM/EDGE Tests application firmware; K8 - Bluetooth Measurement application firmware; K30 - Noise Figure and Gain Measurement application firmware; K73 - 3GPP-FDD UE Trasmitter Test application firmware; K83 - CDMA2000/1XEV-DV Mobile Station application firmware; K84 - 1xEV-DO Base Station Test application firmware; |
http://www.kandelelex.com/jpegs/r&sfsu26 b4-b23-b25-k5-k7-k8-k30-k73-k83-k84.jpg | ||
| Rohde & Schwarz | FSU8 | Spectrum Analyzer 20Hz - 8GHz | http://www.kandelelex.com/jpegs/r&sfsu8.jpg | |||
| Rohde & Schwarz | FSU8 B4-B25-K5-K8-K30-K73-K84 | Spectrum Analyzer 20Hz - 8GHz | Frequency range: 20 Hz to 8 GHz. Reference frequency aging: 1 x 10-7/year. Spectral purity: Phase noise typ. -123 dBc (1 Hz) at 10 kHz from carrier; Residual FM 1Hz. Sweep time: Span ≥10 Hz 2.5 ms to 16000 s; Span 0 Hz (zero span) 1 µs to 16000 s. Resolution bandwidth 10 Hz to 50 MHz, FFT filter: 1 Hz to 30 kHz, channel filter, EMI bandwidth. Video bandwidth:1 Hz to 10 MHz. Display range displayed average noise level to +30 dBm. Displayed average noise level (10 Hz RBW): 1 GHz typ. -148 dBm typ. -148 dBm typ. -146 dBm typ. -146 dBm typ. -146 dBm; 7 GHz - typ. -144 dBm typ. -146 dBm typ. -143 dBm typ. -143 dBm; 13 GHz - - typ. -143 dBm typ. -143 dBm typ. -143 dBm. Displayed average noise level with preamplifier ON (,FSU-B25), 1 GHz, 10 Hz RBW <-152 dBm <-152 dBm <-152 dBm <-152 dBm <-152 dBm. Displayed average noise level with preamplifier ON (,FSU-B23), 26 GHz, 10 Hz. RBW <-140 dBm, typ. -150 dBm. Trace detectors max peak, min peak, auto peak, sample, RMS, average, quasi-peak. Total measurement error, f < 3.6 GHz 0.3 dB. Display linearity 0.1 dB (0 dB to -70 dB).
Features: Versatile resolution filters: Gaussian, FFT, channel, RRC. Comprehensive test routines: TOI, OBW, CCDF; Channel power, ACPR, multicarrier; ACPR. Full choice of detectors: Optional electronic attenuator. Measurement functions for following standards: GSM/EDGE, Bluetoothr wireless technology, TD-SCDMA (BTS/MS), WCDMA node B and UE, HSDPA, cdma2000, cdma2000 1xEV-DO and cdma2000 1xEV-DV (BTS/MS). Speed: Fast ACP test routine in time domain; User-configurable list for fast measurements at frequencies of interest; Up to 70 measurements/s in time domain via IEC/IEEE bus (including trace data transfer). Fast frequency counter with 0.1 Hz resolution in 30 ms. Unrivalled performance. Unmatched dynamic range: TOI typ. +25 dBm, 1 dB compression +13 dBm. Phase noise: typ. -123 dBc (1 Hz) at 10 kHz offset; typ. -160 dBc (1 Hz) at 10 MHz offset. Excellent display linearity <0.1 dB. 84 dB ACLR/3GPP with noise correction. Options: FSU-B4 Low-Aging OXCO FSU-B25 Electronic Attenuator, 0 dB to 30 dB, and 20 dB preamplifier FS-K5 GSM/EDGE Application Firmware FS-K8 Application Firmware for Bluetooth Measurements FS-K30 Application Firmware for Noise Figure and Gain Measurements FS-K73 3GPP UE FDD Application Firmware FS-K84 cdma2000 1xEV-DO BTS Application Firmware |
http://www.kandelelex.com/jpegs/r&sfsu8 b4-b25-k5-k8-k30-k73-k84.jpg | ||
| Rohde & Schwarz | FSU8 K72-K73-K83 | Spectrum Analyzer 20Hz - 8GHz | Frequency range: 20 Hz to 8 GHz. Reference frequency aging: 1 x 10-7/year. Spectral purity: Phase noise typ. -123 dBc (1 Hz) at 10 kHz from carrier; Residual FM 1Hz. Sweep time: Span ≥10 Hz 2.5 ms to 16000 s; Span 0 Hz (zero span) 1 µs to 16000 s. Resolution bandwidth 10 Hz to 50 MHz, FFT filter: 1 Hz to 30 kHz, channel filter, EMI bandwidth. Video bandwidth:1 Hz to 10 MHz. Display range displayed average noise level to +30 dBm. Displayed average noise level (10 Hz RBW): 1 GHz typ. -148 dBm typ. -148 dBm typ. -146 dBm typ. -146 dBm typ. -146 dBm; 7 GHz - typ. -144 dBm typ. -146 dBm typ. -143 dBm typ. -143 dBm; 13 GHz - - typ. -143 dBm typ. -143 dBm typ. -143 dBm. Displayed average noise level with preamplifier ON (,FSU-B25), 1 GHz, 10 Hz RBW <-152 dBm <-152 dBm <-152 dBm <-152 dBm <-152 dBm. Displayed average noise level with preamplifier ON (,FSU-B23), 26 GHz, 10 Hz. RBW <-140 dBm, typ. -150 dBm. Trace detectors max peak, min peak, auto peak, sample, RMS, average, quasi-peak. Total measurement error, f < 3.6 GHz 0.3 dB. Display linearity 0.1 dB (0 dB to -70 dB).
Features: Versatile resolution filters: Gaussian, FFT, channel, RRC. Comprehensive test routines: TOI, OBW, CCDF; Channel power, ACPR, multicarrier; ACPR. Full choice of detectors: Optional electronic attenuator. Measurement functions for following standards: GSM/EDGE, Bluetoothr wireless technology, TD-SCDMA (BTS/MS), WCDMA node B and UE, HSDPA, cdma2000, cdma2000 1xEV-DO and cdma2000 1xEV-DV (BTS/MS). Speed: Fast ACP test routine in time domain; User-configurable list for fast measurements at frequencies of interest; Up to 70 measurements/s in time domain via IEC/IEEE bus (including trace data transfer). Fast frequency counter with 0.1 Hz resolution in 30 ms. Unrivalled performance. Unmatched dynamic range: TOI typ. +25 dBm, 1 dB compression +13 dBm. Phase noise: typ. -123 dBc (1 Hz) at 10 kHz offset; typ. -160 dBc (1 Hz) at 10 MHz offset. Excellent display linearity <0.1 dB. 84 dB ACLR/3GPP with noise correction. Options: FS-K72 Modulation and code domain power measurements to 3GPP TS 24.141 on base station signals (node B) FS-K73 Modulation and code domain power measurements to 3GPP TS 25.121 on mobile station signals (UE) FS-K83 Modulation and code domain power measurements on cdma2000/1xEV-DV mobile station signals (UE) |
http://www.kandelelex.com/jpegs/r&sfsu8 k72-k73-k83.jpg | ||
| Rohde & Schwarz | HK116 | Biconical Dipole Antenna 20 - 300MHz | HK116
Frequency range 20 to 300 MHz Polarization linear Nominal impedance 50 W VSWR 2.5 typ. Max. input power 20 W Connector N female Operating temperature -40 to +55°C Dimensions (L x W x H) 1380 mm x 530 mm x 720 mm Weight 3 kg |
http://www.kandelelex.com/jpegs/r&shk116.jpg | ||
| Rohde & Schwarz | HL223 | Log Periodic Antenna 200-1300MHz | HL223
Frequency range 200 to 1300 MHz Polarization linear Nominal impedance 50 W VSWR 2, typ. 1.6 Max. input power 1500 to 600 W CW Gain >6 dBi Connector N female Max. wind speed 200 km/h (without ice deposit) Dimensions (L x W) 710 mm x 765 mm Weight 2 kg |
|||
| Rohde & Schwarz | NRP-Z11 | Universal Power Meter-Sensor 10MHz-8GHz 200pW(-67d | The R&S®NRP-Z11 universal rf power sensor is, with a dynamic range of 90 dB for measurement of CW and modulated signals and a maximum power of +23 dBm, a very useful measurement instrument for a vast number of measurement tasks.
*True universal power sensor for a vast number of applications *10 MHz to 8 GHz *-67 dBm to +23 dBm (200 pW to 200 mW) *90 dB dynamic range for CW and modulated signals *Innovative three-path diode power sensor with enhanced inter-range performance *Continuous average, burst average, timeslot average, time gating and trace mode supported (video bandwidth 100 kHz) *Automatic burst detection and acquisition *Up to 1500 measurements/s (buffered mode) *Low sensitivity to harmonics |
in stock | ||
| Rohde & Schwarz | NRVZ5 | Diode Sensor 100KHz-6GHz 10nw-500mw | The Rohde & Schwarz NRV-Z5 is a medium-sensitivity sensor. Based on diode detectors with 20 dB attenuator, these sensors provide true RMS power measurement in the range from 10 nW to 1 mW and up to 500 mW for sinewave signals. Compared to thermocouple sensors, shorter measurement times can be attained with these sensors. N connector. | |||
| Rohde & Schwarz | NRVZ55 | Thermocouple Power Sensor DC - 40GHz 1uw - 100mw | Thermal power sensor 50 Ohm 0 - 40 GHz, 1 µW - 100 mW K (2.92 mm) male, 1.3 m cable (p/n 1081.2005.02) | in stock | ||
| Rohde & Schwarz | SME03 | Signal Generator 5KHz - 3GHz | Frequency: 5KHz to 3GHz with .1Hz resolution. Output: -144 to +13(16dBm) with .1dB(.01)dB resolution and ±1dB accuracy. SSB Phase Noise(@1GHz): -126dBc/Hz(20KHz offset). Features: sweep; GP-IB; 50W RF,35VDC overload protection; self diagnostics. Options: B1=<.001 ppm/day Reference Oscillator; | http://www.kandelelex.com/jpegs/r&ssme03.jpg | in stock | |
| Rohde & Schwarz | SME03 B1-B4-B5-B8-B11-B12 | Signal Generator 5KHz - 3GHz | Frequency: 5KHz to 3GHz with .1Hz resolution. Output: -144 to +13(16dBm) with .1dB(.01)dB resolution and ±1dB accuracy. SSB Phase Noise(@1GHz): -126dBc/Hz(20KHz offset). Features: sweep; GP-IB; 50W RF,35VDC overload protection; self diagnostics. Options: B1=<.001 ppm/day Reference Oscillator; B4=Pulse Generator; B5=FM/Phase modulator; b8=Pulse Modulator; B11=DM Decoder; B12=DM Memory(8Mbit). | http://www.kandelelex.com/jpegs/r&ssme03 b1-b4-b5-b8-b11-b12.jpg | in stock | |
| Rohde & Schwarz | SME06 | Signal Generator 5KHz-6GHz | Frequency: 5KHz to 6GHz with .1Hz resolution. Output: -144 to +13(16dBm) with .1dB(.01)dB resolution and ±1dB accuracy. SSB Phase Noise(@1GHz): -126dBc/Hz(20KHz offset). Features: sweep; GP-IB; 50W RF,35VDC overload protection; self diagnostics. Options: B1=<.001 ppm/day Reference Oscillator; B2=LF Generator up to 500KHz; B4=Pulse Generator; B5=FM/Phase Modulation; B9=Pulse Modulator; B11=DM Decoder(Mod Types:FSK,4FSK,FFSK,GFSK,GMSK,QPSK.) | http://www.kandelelex.com/jpegs/r&ssme06.jpg | ||
| Rohde & Schwarz | SMG/B1/B2 | Signal Generator/100KHz-1GHz/TCXO | Frequency Range: 100KHz to 1000MHz with 1Hz resolution. Level: -137 to +13dBm(overrange +16dBm) with 0.1dB resolution. Spectral purity: harmonics;<-30dBc, <-140dBc broadband noise. Modulation: AM, FM(dc to 100KHz), FSK, PhM, and pulse. RF and AF(option B2) sweep. Option B2 offers an internal modulation generator, 10Hz to 100KHz. Option B1 is a 10MHz, 1 x 10(-9) time base. | |||
| Rohde & Schwarz | SMHU52 | Synthesised Signal Generator 100KHz - 4.32GHz | Features:
Extremely high spectral purity Frequency setting time <1 ms Frequency resolution 0.1 Hz RF, AF, level and memory sweeps Broadband FM from DC to 1 MHz Frequency-accurate and drift-free FM DC for FSK applications OCXO as a reference Pulse modulator |
http://www.kandelelex.com/jpegs/r&ssmhu52.jpg | in stock | |
| Rohde & Schwarz | SMHU56 | RF Signal Generator 100KHz - 4320MHz +19dBm Outpu | The SMHU56 Signal Generator can generate complex test signals for modern communications and radar systems. Its high versatility is based upon the great variety of modulation capabilities in conjunction with high spectral purity and frequency hopping.
The I/Q and the broadband AM/FM modulators make all digital and analog modulation modes for directional radio and satellite communications possible. Modern radio networks use digital modulation methods, for which the SMHU58 is ideally suited due to the high accuracy of its I/Q modulator. For modulation using serial data signals, coders can be integrated for the necessary signal processing and filtering to relevant standards. The optional coders produce filtered analog signals from a serial data stream for driving the I/Q modulator. The accuracy of the resulting phase modulation meets all requirements placed on a reference signal for NADC, DECT, PDC, and GSM testing. The CDMA coder uses Qualcomm chips to generate standard channels. Broadband FM can be used for fast FSK, analog sweeping, video modulation, and for generating chirp signals. I/Q Modulator for Any Phase and Amplitude Modulation (PSK, QAM, ASK, etc.), Modulation Bandwidth DC to 200 MHz Second, Coherent Carrier for Simple I/Q Demodulation Broadband Amplitude Modulation for TV Applications Broadband Frequency Modulation for Satellite Communications, Radar, and Video Applications Optional Coders for Generating Modulating Signals for Digital Radio Networks to Relevant Standards (GSM, NADC, DECT, CDMA) Frequency Hopping - 4800 Stored Frequency and Level Settings Parallel Bus Interface for External Addressing of Memories Setting Time <1 ms for Frequency-agile Systems High Spectral Purity for Out-of-channel Measurements and LO Applications High Output Power (+19 dBm) High Carrier Frequency Accuracy and Drift-free FM DC for FSK and VCO Modes Fast AM DC for Generating Level Bursts RF, AF, Level, and Memory Sweeps for Automatic Test Runs |
http://www.kandelelex.com/jpegs/r&ssmhu56.jpg | in stock | |
| Rohde & Schwarz | SMHU58 | RF Signal Generator 100KHz - 4320MHz +19dBm Outpu | The SMHU58 Signal Generator can generate complex test signals for modern communications and radar systems. Its high versatility is based upon the great variety of modulation capabilities in conjunction with high spectral purity and frequency hopping.
The I/Q and the broadband AM/FM modulators make all digital and analog modulation modes for directional radio and satellite communications possible. Modern radio networks use digital modulation methods, for which the SMHU58 is ideally suited due to the high accuracy of its I/Q modulator. For modulation using serial data signals, coders can be integrated for the necessary signal processing and filtering to relevant standards. The optional coders produce filtered analog signals from a serial data stream for driving the I/Q modulator. The accuracy of the resulting phase modulation meets all requirements placed on a reference signal for NADC, DECT, PDC, and GSM testing. The CDMA coder uses Qualcomm chips to generate standard channels. Broadband FM can be used for fast FSK, analog sweeping, video modulation, and for generating chirp signals. I/Q Modulator for Any Phase and Amplitude Modulation (PSK, QAM, ASK, etc.), Modulation Bandwidth DC to 200 MHz Second, Coherent Carrier for Simple I/Q Demodulation Broadband Amplitude Modulation for TV Applications Broadband Frequency Modulation for Satellite Communications, Radar, and Video Applications Optional Coders for Generating Modulating Signals for Digital Radio Networks to Relevant Standards (GSM, NADC, DECT, CDMA) Frequency Hopping - 4800 Stored Frequency and Level Settings Parallel Bus Interface for External Addressing of Memories Setting Time <1 ms for Frequency-agile Systems High Spectral Purity for Out-of-channel Measurements and LO Applications High Output Power (+19 dBm) High Carrier Frequency Accuracy and Drift-free FM DC for FSK and VCO Modes Fast AM DC for Generating Level Bursts RF, AF, Level, and Memory Sweeps for Automatic Test Runs |
http://www.kandelelex.com/jpegs/r&ssmhu58.jpg | in stock | |
| Rohde & Schwarz | SMIQ03 | Vector Signal Generator 300 KHz To 3.3 GHz | 0.3 GHz to 3.3 GHz, 0.1 Hz resolution
Versatile and Broadband Generation of Digitally Modulated Signals up to 7 Msymbol/s Analog and Digital Modulation Capabilities Generation of TDMA and CDMA Signals to all Main Mobile Radio Standards Broadband I/Q Modulator with Outstanding Vector Accuracy Optional Internal Fading Simulator to Test Specifications of Mobile Radio Standards Option: B1: OXCO Reference Oscillator B5: FM Phase modulation B10: Digital modulation B11: Internal data generator incl. 4 Mbit memory |
http://www.kandelelex.com/jpegs/r&ssmiq03.jpg | ||
| Rohde & Schwarz | SMIQ03 B50 | Vector Signal Generator 300KHz - 3.3GHz | 0.3 GHz to 3.3 GHz, 0.1 Hz resolution
Versatile and Broadband Generation of Digitally Modulated Signals up to 7 Msymbol/s Analog and Digital Modulation Capabilities Generation of TDMA and CDMA Signals to all Main Mobile Radio Standards Broadband I/Q Modulator with Outstanding Vector Accuracy Optional Internal Fading Simulator to Test Specifications of Mobile Radio Standards Option: B1: OXCO Reference Oscillator B5: FM Phase modulation B10: Digital modulation B11: Internal data generator incl. 4 Mbit memory B50: High-Speed CPU |
http://www.kandelelex.com/jpegs/r&ssmiq03 b50.jpg | in stock | |
| Rohde & Schwarz | SMIQ03B | Vector Signal Generator 300KHz - 3.3GHz | The Rohde & Schwarz SMIQ03B Signal Generator offers solutions for today and tomorrow. Frequency Range: 300KHz to 3.3GHz with .1Hz resolution and <1x100(-6)/year accuracy. Output: -144dBm to +13dBm with 0.1 and .01dB resolution and <.9dB uncertainty. Analog and Digital modulation. Versatile and broadband generation of digitally modulated signals up to 18Msymbol/s. Broadband I/Q modulator with outstanding vector accuracy. | http://www.kandelelex.com/jpegs/r&ssmiq03b.jpg | in stock | |
| Rohde & Schwarz | SMIQ03B B1-B11-B12-B14-B17-B20 | Vector Signal Generator 300KHz-3.3GHz | The Rohde & Schwarz SMIQ03B Signal Generator offers solutions for today and tomorrow. Frequency Range: 300KHz to 3.3GHz with .1Hz resolution and <1x10(-9)/day
accuracy(opt.B1). Output: -144dBm to +13dBm with 0.1 and .01dB resolution and <.9dB uncertainty. Analog and Digital modulation. Versatile and broadband generation of digitally modulated signals up to 18Msymbol/s. Broadband I/Q modulator with outstanding vector accuracy. Options: B1 Reference Oscillator B11 Data Generator And TDMA Standards B12 32 Mbit Memory Extension B14 Fading Simulator,1085.4002.02 B17 Noise And Distortion Generator B20 Modulation Coder |
http://www.kandelelex.com/jpegs/r&ssmiq03b b1-b11-b12-b14-b17-b20.jpg | ||
| Rohde & Schwarz | SMIQ03E B10-B11 | Vector Signal Generator 300KHz - 3.3GHz | The economy models SMIQ02E and SMIQ03E have especially been designed for the needs in production, environments and satisfy the requirement for an economically attractive solution with an outstanding price/performance ratio.
Main features Versatile and broadband generation of digitally modulated signals up to 7 Msymbol/s Analog and digital modulation capabilities Generation of TDMA and CDMA signals to all main mobile radio standards Broadband I/Q modulator with outstanding vector accuracy Optional internal fading simulator to test specifications of mobile radio standards Frequency Range 300 kHz - 3.3 GHz. Frequency Resolution 0.1 Hz. Output Range -140 dBm to +13 dBm. Output Resolution 0.1 dB. Time Base Stability 0.000001 ppm. Spectral purity: Harmonics at level Ł10 dBm <-30 dBc; SSB phase noise at 1 GHz, carrier offset 20 kHz, 1 Hz bandwidth; SMIQ02E/SMIQ03E CW <-116 dBc; Vector modulation: <-113 dBc. Modulation with SMIQ02E/SMIQ03E: Frequency/phase modulation internal, external AC/DC, two-tone with two modulation channels; with PM: bandwidth 2 MHz only for channel 2 Max. deviation FM PhM, bandwidth 100 kHz/2 MHz depending on carrier frequency: 5 to 20 MHz, 50 to 200 rad/2.5 to10 rad. Modulation frequency range FM DC to 8 MHz. Digital standards with options SMIQB10 and SMIQB11: GSM, NADC, PDC, PHS, CDMA, IS-95. |
http://www.kandelelex.com/jpegs/r&ssmiq03e b10-b11.jpg | in stock | |
| Rohde & Schwarz | SMP02 | Microwave Signal Generator 2-20GHz | The Microwave Signal Generator R&S SMP is a reliable, high-precision signal source featuring high output power, high spectral purity and excellent pulse modulation. It is able to supply different modulations for any measurement on radar and communication equipment. A wide range of options ensures universal use in R&D, production, EMC and environmental measurements as well as in material testing.
Spectral purity is one of the most important parameters for many applications. The R&S SMP family offers the lowest SSB phase noise of typical -109 dBc (1 Hz) at f = 10 GHz and 10 kHz offset.A classical field of application for microwave generators is the testing of radar receivers. Each R&S SMP has a precise pulse modulator built in by default.In addition to conventional CW capabilities, the R&S SMP family also supports classical analog modulation without any restrictions. The basic unit includes not only AM, FM and SCAN, but the digital modulation types ASK and FSK as well. The different modulations can also be combined to create more realistic signals. |
http://www.kandelelex.com/jpegs/r&ssmp02.jpg | ||
| Rohde & Schwarz | SMP04 B1-B2-B5-B11-B12-B13-B14 | Microwave Signal Generator 10MHz - 40GHz | The Microwave Signal Generator R&S SMP is a reliable, high-precision signal source featuring high output power, high spectral purity and excellent pulse modulation. It is able to supply different modulations for any measurement on radar and communication equipment. A wide range of options ensures universal use in R&D, production, EMC and environmental measurements as well as in material testing.
Optional pulse modulator and pulse generator Digital RF, AF and level sweep Storage of 50 complete instrument setups Optional phase modulator ASK/FSK modulation, phase offset settings Extremely low SSB phase noise at 10 GHz (<–105 dBc (1 Hz) at 10 kHz from carrier) Very short frequency setting time <11 ms + 5 ms/GHz Extremely high level accuracy <±0.9 dB at 0 dBm in frequency range 10 MHz to 40 GHz Options: SMP-B1 - OCXO Reference Oscillator SM-B2 - LF Generator SM-B5 – FM / pM Modulator SMP-B11 - Frequency Extension SMP-B12 - Pulse Modulator SMP-B13 - Pulse Modulator SMP-B14 - Pulse Generator |
in stock | ||
| Rohde & Schwarz | SMU200A B10-13-103-203-K11-12-17-40-42-43-61 | Vector Signal Generator | Specifications:
Frequency range: 100 kHz to 3GHz. Setting time <3 ms. Setting time in List mode <450 µs. Level Range -145 dBm to +13 dBm (PEP, 3 GHz). Range with high-power output option -145 dBm to +19 dBm (PEP, 3 GHz). Spectral purity (at f = 1 GHz): Nonharmonics; Carrier offset >10 kHz; Carrier offset >850 kHz; <-80 dBc; <-86 dBc. SSB phase noise(20 kHz carrier offset, 1 Hz measurement bandwidth) typ. -135 dBc. Wideband noise (carrier offset >5 MHz, 1 Hz measurement bandwidth): typ. -153 dBc (CW); typ. -149 dBc (I/Q modulation). ACLR; 3GPP test model 1, 64 DPCHs typ. 70 dB RF modulation bandwidth. Using external I/Q inputs 200 MHz. Using internal baseband section 80 MHz. Supported modulation types: AM DC to 500 kHz. Pulse 0 kHz to 100 kHz. ASK 0 % to 100 %; FSK MSK, 2FSK, 4FSK, PSK BPSK, QPSK, OQPSK, π/2 DBPSK, π/4 DQPSK, π/8 D8PSK, π/4 QPSK, 8PSK, 8PSK EDGE, QAM 16QAM, 32QAM, 64QAM, 256QAM, 1024QAM. Supported standards and digital systems: GSM/EDGE, 3GPP FDD, 3GPP TDD, TD-SCDMA, cdmaOne, CDMA2000r, 1 x EV-DO, IEEE 802.11a, IEEE 802.11b, IEEE 802.11g, TETRA, Bluetoothr, AWGN, user-defined multicarrier CW. Interfaces: IEEE 488.2, LAN (100BaseT), 3 x USB, 1 x USB slave, VGA. Options: RF Path A: SMU-B103 100 kHz to 3 GHz RF Path B: SMU-B203 100 kHz to 3 GHz Baseband 2)SMU-B10 Baseband Generator with ARB (64 Msamples) and Digital Modulation (realtime) 2)SMU-B13 Baseband Main Module Digital modulation systems SMU-K40 Digital Standard GSM/EDGE SMU-K42 Digital Standard 3GPP FDD SMU-K61 Multicarrier CW Signal Generation Digital modulation systems using WinIQSIMT SMU-K11 Digital Standard IS-95 (with WinIQSIMT) SMU-K12 Digital Standard CDMA2000r (with WinIQSIMT) SMU-K17 Digital Standard 1xEV-DO (with WinIQSIMT) |
|||
| Rohde & Schwarz | SMY02 | Signal Generator 9 KHz To 2.08 GHz | The SMY02 Signal Generator is a cost-effective instrument for testing AM, FM, and ΦM receivers and for component measurements.
Frequency Range 9 kHz to 2.08 GHz Frequency Resolution 1 Hz Level Range -140 to +13 dBm, Over Range up to 19 dBm Level Accuracy Better than 1 dB SSB Phase Noise <-114 dB at 1 GHz, DELTAf = 20 kHz AM, FM, phiM, and Pulse Modulation Modulation Generator 1 Hz to 500 kHz RF Overload Protection 50 W (SMY02) Low RF Leakage (<0.1 µV) Non-volatile Storage for up to 50 Complete Front-panel Setups GPIB Calibration at 3-Year Interval |
in stock | ||
| Rohde & Schwarz | SMY02 | Signal Generator 9 KHz To 2.08 GHz | The SMY02 Signal Generator is a cost-effective instrument for testing AM, FM, and ΦM receivers and for component measurements.
Frequency Range 9 kHz to 2.08 GHz Frequency Resolution 1 Hz Level Range -140 to +13 dBm, Over Range up to 19 dBm Level Accuracy Better than 1 dB SSB Phase Noise <-114 dB at 1 GHz, DELTAf = 20 kHz AM, FM, phiM, and Pulse Modulation Modulation Generator 1 Hz to 500 kHz RF Overload Protection 50 W (SMY02) Low RF Leakage (<0.1 µV) Non-volatile Storage for up to 50 Complete Front-panel Setups GPIB Calibration at 3-Year Interval |
http://www.kandelelex.com/jpegs/r&ssmy02.jpg | in stock | |
| Rohde & Schwarz | UAF | Video Analyzer | The Rohde & Schwarz UAF signal analysis comprises 25 video and test line parameters and covers all important levels as well as linear and nonlinear distortions such as 2T K rating, frequency response and hum. The position of the test lines can be freely selected over the entire picture area and in the field blanking interval; storage of up to eight test configurations is possible. Owing to its variable integration time, the R&S UAF can be adapted to all test conditions. Using the shortest integration time of less than 1 s, the R&S UAF is ideal for all alignments, be it in the studio or in production.
Features ? Ease of operation ? 3 signal inputs ? 25 video parameters ? Limit monitoring ? Full-field measurements ? Convenient result display ? Freely selectable test signal ? Memory card ? Printer interface ? Remote control (IEC/IEEE bus) ? Small dimensions ? High-speed measurements |
http://www.kandelelex.com/jpegs/r&suaf.jpg | ||
| Rohde & Schwarz | URV5 | RF DC Millivoltmeter Power Meter 2-Channel | Millivoltmeter URV5 is a broadband voltage, level and power meter of high accuracy and sensitivity. It is suitable both for manual operation and for use in systems. A wide choice of individually calibrated probes and sensors allows URV5 to be used for a great variety of measurements:
With RF probe and DC probe for no-load AC and DC voltage measurements Voltage (and power) measurements in coaxial 50 W and 75 W systems using low-reflection and low-loss insertion units Power measurements up to 26.5 GHz using Power Sensors NRV-Z1 to -Z6 |
http://www.kandelelex.com/jpegs/r&surv5.jpg | in stock | |
| Rohde & Schwarz | ZVC62 B2-B4-B5-B7-K9-B16 | 8GHz Network Analyzer | The Rohde & Schwarz, Inc. ZVC62 network analyzer is an instrument which measures the complex transmission and reflection characteristics of two-port devices in the frequency domain. It does this by sampling the incident signal, separating the transmitted and reflected waves, and then performing ratios that are directly related to the reflection and transmission coefficients of the two-port. Frequency is swept to rapidly obtain amplitude and phase information over a band of frequencies of interest.
Rohde & Schwarz, Inc. ZVC62 network analyzers utilize synthesized-frequency sources to provide a known test stimulus that can sweep across a range of frequencies or power levels. Rohde & Schwarz, Inc. ZVC62 network analyzers also can perform ratioed measurements (including phase), which require multiple receivers. The Rohde & Schwarz, Inc. ZVC62 can provide a wealth of knowledge about a device under test (DUT), including its magnitude, phase, and group-delay response. Features Excellent dynamic range: >130 dB (IF bandwidth 10 Hz) Low inherent noise : <-130 dBm (measurement bandwidth 3 kHz) Broad frequency range for universal use: 20 kHz to 8 GHz (ZVCE, ZVC) High measurement speed: <125 µs/point (normalized) <240 µs/point (fully calibrated) Fast data transfer via IEC/IEEE bus: Transfer time <15ms (200 points) High sweep rate: >>25 sweeps/s (200 points) Manual calibration techniques: TOM, TRM, TRL, TNA, TOM-X, TOSM Automatic calibration AutoKal: Compatibility with PC, CAE Internal PC with Windows NT operating system suitable for PC applications |
|||
| Roto Form Mfg Corp | 151 | Roto II Lead Former And Cutter | The Roto IIr, Model 151 Axial Component Former combines the time proven tape fed design with a non-jamming mechanized "walking beam" Loose Parts Feeder to give you the best of both techniques in one economical machine. You can leave both feeders mounted on the machine and simply load the one you need. Easy to use and adapts to most sizes. Includes optional counter that can be preset to stop after count is reached. | in stock | ||
| Roto Form Mfg Corp | 172 | Roto-trim Circuit Board Lead Trimmer | This machine has a variable speed cutting blade and is manually operated. The board is held in place by clamps on the platform. | |||
| Sage | 930A | Service Monitor | The Sage 930A is a used Combination Test Set that is designed to meet all of the applications associated with testing Network Switching and DS1 Facilities. The standard Sage 930A is a high performance Signaling, TIMS and Return Loss Measuring Set with a built-in DP, MF and DTMF sender.
Features: 2- and 4-Wire Access; Loop & Ground Start; Reverse Battery; E&M Signaling Types I and V; Level and Frequency (20 Hz to 5 kHz); C-MSG, C-Notch, 3 kHz Flat Noise; Signal-to-Noise Ratio; 2- and 4- Wire Return Loss; DP, MF & DTMF Sender with Talk Battery; DC Volt and Milli-ammeter; Wink Timing; Impedances 150, 600, 900 & 1200. |
in stock | ||
| Saunders & Associates | 100HF | Crystal Impedance Meter | Line test crystal oscillator; 1 to 60MHz. | in stock | ||
| Schaffner | NSG2025-3 | Fast Transient Burst Generator 4.4kV 1MHz 30A 1-Ph | The Schaffner NSG 2025 is a high end burst generator and the choice for users who need the maximum in pulse amplitude/frequency capabilities, flexibility, coupling network features and EUT connectivity. Based on a 'buildingblock' concept, the Schaffner NSG 2025 lets you select and combine pulse generator, coupling and EUT adapters to create a flexible, upgradeable EMC test work station to match your needs today and into the future. It covers all the widely used burst test specifications of IEC, EN, ANSI-IEEE as well as the known extended manufacturer's requirements.
The Schaffner NSG 2025 offers the most extensive range of pulse voltages and burst frequencies available in a single instrument. Pulses can be coupled into the mains supply voltage or applied as a pure high voltage for data and signal line testing. Pre-programmed IEC standard tests are available at the touch of a button and pulse parameters are user configurable - manually via front panel control or via PCWindows software control. Not only does the Schaffner NSG 2025 meet all the requirements of current world test standards with comfortable margins, it also anticipates likely future modifications with functions including a user-configurable burst frequency to 1MHz and extended selectable coupling modes. Specifications: Unit Power: 100 - 115 V and 220 - 240 V, 50 - 60 Hz Pulse Amplitude: 200 V to 4.5 or 8 kV (open circuit) adjustable in steps of 20 V Polarity: positive or negative, selectable Rise Time: 5ns ±20% (50 W, 10 - 90%) Pulse Width: 50ns ±30% (50 W and 1 W), 100ns ±50% open circuit Pulses Per Packet: 1 to 150 pulses Burst Duration: Pulses per packet / burst frequency, (15ms burst duration as per IEC 1000-4-4 up to 10 kHz) Burst Repetition: 100ms to 10s ±2ms or 2% Impedance: 50 W ±20% Coupling Network: 1-phase or 3-phase EUT Supply: Switched by remote control, 24 to 500 Vac, 50 - 60 Hz Coupling Modes: Line to reference ground (IEC 1000-4-4), selected lines together to reference ground, all lines to reference ground (common mode) Phase Angle: Asynchronous/synchronous 0 - 360° ±2° Coupling Capacitance: 33 nF Decouple Attenuation: >20 dB Cross Talk Attenuation: >30 dB Weight: 55.1 lbs (25 Kg) |
http://www.kandelelex.com/jpegs/sfrnsg2025-3.jpg | ||
| Schaffner | NSG-203A | AC Voltage Variation And Dropout Plug-in | Used in NSG-200 mainframe.. Simulates complete power interrupts and brownouts. | |||
| Schaffner | NSG-431 | E.S.D. Simulator | Test electrostatic charging between person and machine. Discharge voltage: 2 to 21KV. Repetition Frequency: approx. 20Hz. Positive polarity, single or continuous mode of operation. | in stock |